| Literature DB >> 35633218 |
Malati Dulal1, Prashant Tripathi1, Amit Shrestha2, Kunjan Acharya1, Sailesh Niroula2.
Abstract
Clinical findings of foreign body aspiration, generally, are subtle. Scrutinous clinical suspicion is always recommended. Here, we present a rare case of an adult male, who under the influence of alcohol had aspirated a row of his artificial denture without his conscience of where his denture got missing and presented to our outpatient department with non-specific symptoms. With clinical examination and advanced diagnostics, he was successfully managed with rigid bronchoscopy. With the advancement in diagnostic techniques and our widened knowledge of the condition, utmost early detection has been possible and our case report reinforces the need for a low threshold for foreign body aspiration suspicion, especially in adults with dentures, and the use of rigid bronchoscopy as a plausible tool for the prompt management of the aspiration. Keywords: bronchoscopy; case reports; dentures; foreign bodies.Entities:
Mesh:
Year: 2022 PMID: 35633218 PMCID: PMC9252251 DOI: 10.31729/jnma.7314
Source DB: PubMed Journal: JNMA J Nepal Med Assoc ISSN: 0028-2715 Impact factor: 0.556