The purpose of this study was to explore sampling options for a reliable and logistically more feasible protocol during a large EHV-1 outbreak. Seventeen horses with clinical infection as well as nineteen healthy herdmates, all part of an EHM outbreak, were enrolled in the study. Each horse was sampled two-four times at intervals of 2-6 days during the outbreak. All samples were collected using 6'' rayon-tipped swabs. Nasal secretions were used as the diagnostic sample of choice. Additional samples, including swabs from the muzzle/nares, swabs from the front limbs, rectal swabs, swabs of the feed bin, and swabs of the water troughs were collected as well. All swabs were tested for the presence of EHV-1 by qPCR. With the exception of two EHV-1 qPCR-positive swabs from two different horses, all remaining swabs collected from healthy herdmates tested qPCR-negative for EHV-1. For horses with clinical infection, EHV-1 was detected in 31 nasal swabs, 30 muzzle/nares swabs, 7 front limb swabs, 7 feeders, 6 water troughs and 6 rectal swabs. Not all positive muzzle/nares swabs correlated with a positive nasal swab from the same set, however, and all other positive swabs did correlate with a positive nasal swab in their respective set. The agreement between nasal swabs and muzzle/nares swabs was 74%. The sampling of non-invasive swabs from the muzzle/nares should facilitate the identification of EHV-1 shedders during an outbreak, allowing for prompt isolation and implementation of biosecurity measures.Entities:
Keywords: EHV-1; diagnostic samples; equine; outbreak; qPCR
Year: 2022 PMID: 35631095 PMCID: PMC9144909 DOI: 10.3390/pathogens11050574
Source DB: PubMed Journal: Pathogens ISSN: 2076-0817
qPCR results for EHV-1 in nasal swabs, muzzle/nares swabs, front limb swabs, rectal swabs, feeder swabs, water trough swabs from 32 horses with clinical EHV-1 infection, and healthy herdmates. Sample sets were collected 2–4 times at intervals of 2–6 days for each study horse. The results are reported as number of EHV-1 qPCR-positive and qPCR-negative swabs. The quantitative results (range and median in parenthesis) are expressed as number of gB genes per µL of purified DNA.
| Nasal | Muzzle/Nares | Front Limbs | Rectal | Feeder | Water Trough | |
|---|---|---|---|---|---|---|
| 31/13 | 30/14 | 7/37 | 6/38 | 7/37 | 6/38 | |
| Quantiative results | 2.3–3.0 × 106 (1899) | 1.5–4.0 × 105 (1320) | 3.5–168.9 (5.5) | 9.8–250.8 (23.8) | 1.4–809.3 (21.2) | 1.9–107.6 (23.7) |
| 1/49 | 1/49 | 0/50 | 0/50 | 0/50 | 0/50 | |
| Quantitative results | 2.3 | 5.3 | Not applicable | Not applicable | Not applicable | Not applicable |
Figure 1Absolute quantitation for each EHV-1 qPCR results from nasal swabs, nares/muzzle swabs, front limb swabs, rectal swabs, feeder swabs, and water trough swabs. The results are expressed as the number of target gB genes per µL of purified DNA. The horizontal red lines represent the median values.