Literature DB >> 35626886

Reply to Nyman, U.; Aspelin, P. Regarding Iodixanol for Pediatric CTA. Comment on "Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation-Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949".

Marian Pop1,2.   

Abstract

We greatly appreciate the letter by Nyman et al. [...].

Entities:  

Year:  2022        PMID: 35626886      PMCID: PMC9140064          DOI: 10.3390/children9050709

Source DB:  PubMed          Journal:  Children (Basel)        ISSN: 2227-9067


We greatly appreciate the letter by Nyman et al. [1] to our manuscript titled “Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation—Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320” [2] that describes our experience in using four different contrast agents in pediatric CT angiography for infants referred for aortic arch evaluation. We agree that obtaining proper contrast enhancements in computed tomography the iodine delivery rate (IDR) is of particular importance, as demonstrated by the detailed studies mentioned [3,4]. Unfortunately, the retrospective nature of our study allowed us to compare images acquired using the Technical Recommendations of the Society for Cardiovascular CT [5] where only flow (mL/s) and volume recommendations were available. Moreover, we would like to note that there was no statistically significant difference between IDRs for different contrast agents. Per methodology, data were tested for normality using the D’Agostino–Pearson test, with a one-way analysis of variance (ANOVA) or Kruskal–Wallis test used to verify differences between groups. Therefore, in the tables, either mean or median were being displayed. We acknowledge the fact that differences in cardiac output and presence of significant comorbidities are of importance, but unfortunately such data fall outside of the purpose of the study and we can only regret that we have no such data to increase the strength of our results. We agree with the qualities that allowed iodixanol to be used with great success in patients with impaired kidney function and that it is used with excellent results in the general pediatric CT examinations, and that, as pointed out [1], osmolality is of particular importance in neonates and small children. Numan et al. [1] correctly pointed out that data regarding the injection site and catheter being used are not available but, historically, a 24- or 26-gauge canula placed in the upper extremities can be used. We can confirm, however, that all examinations were performed using a room-temperature contrast agent; therefore, we postulated that the differences in enhancement might be due to differences in viscosity. This is recognized also by the American College of Radiology guidelines [6] stating that “If a rapid injection rate is desired through a small angiocatheter and if contrast medium viscosity is high, …, the desired injection flow rate may not be achieved”. We would like to thank our colleagues for the suggestion of using a low-viscosity Iodixanol 270, and we are currently working towards its local availability. We hope that we have cleared any misunderstandings regarding the methodological side of the analysis. CT angiography in infants remains a challenging procedure, especially in patients with congenital cardiovascular diseases, with proper enhancement of the vessels representing a multivariable function. We agree that we had available a limited sample and we are accepting that we do not know exactly why using similar acquisition and injection protocols with Iodixanol 320 provided up to 40% less enhancement of the large vessels when compared to the other contrast mediums we had available; however, in our opinion, more data and more comparative studies are required to properly establish the justification of its usage in infant CT angiography.
  5 in total

1.  Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: a randomized study.

Authors:  Hiromasa Suzuki; Hidekazu Oshima; Norio Shiraki; Chisa Ikeya; Yuta Shibamoto
Journal:  Eur Radiol       Date:  2004-08-12       Impact factor: 5.315

Review 2.  Computed Tomography Imaging in Patients with Congenital Heart Disease, Part 2: Technical Recommendations. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT): Endorsed by the Society of Pediatric Radiology (SPR) and the North American Society of Cardiac Imaging (NASCI).

Authors:  B Kelly Han; Cynthia K Rigsby; Jonathon Leipsic; Dianna Bardo; Suhny Abbara; Brian Ghoshhajra; John R Lesser; Subha V Raman; Andrew M Crean; Edward D Nicol; Marilyn J Siegel; Anthony Hlavacek
Journal:  J Cardiovasc Comput Tomogr       Date:  2015-08-28

3.  Regarding Iodixanol for Pediatric CTA. Comment on Pop, M. Cardiothoracic CTA in Infants Referred for Aortic Arch Evaluation-Retrospective Comparison of Iomeprol 350, Ioversol 350, Iopromide 370 and Iodixanol 320. Children 2021, 8, 949.

Authors:  Ulf Nyman; Peter Aspelin
Journal:  Children (Basel)       Date:  2022-05-10

4.  Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight.

Authors:  Kazuo Awai; Kumiko Hiraishi; Shinichi Hori
Journal:  Radiology       Date:  2004-01       Impact factor: 11.105

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.