Literature DB >> 35612548

Diagnostic test accuracies of F-18 FDG PET for characterisation of cardiac masses compared to conventional imaging techniques: systematic review and meta-analysis.

Keunyoung Kim1, Woo Seog Ko1, Seong-Jang Kim1.   

Abstract

OBJECTIVE: The present systematic review and meta-analysis compared the diagnostic performance of F-18 fludeoxyglucose positron emission tomography (18F-FDG PET) and conventional imaging, including MRI, echocardiography, and CT, in characterising cardiac masses.
METHODS: A literature search of the PubMed, Cochrane, and EMBASE databases for studies comparing the diagnostic accuracies of 18F-FDG PET and conventional imaging in characterising cardiac masses, from inception of indexing to 31 July 2020, was performed. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess study quality. Sensitivity and specificity across the studies were determined, positive and negative likelihood ratios (LR+ and LR-, respectively) were calculated, and summary receiver operating characteristic curves were constructed.
RESULTS: Of six included studies (n = 212 patients), 18F-FDG PET demonstrated a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.81-0.94) and a pooled specificity of 0.89 (95% CI 0.80-0.94). LR syntheses yielded an overall LR+ of 7.9 (95% CI 4.3-14.6) and LR- of 0.12 (95% CI 0.07-0.22). The calculated pooled diagnostic odds ratio (DOR) was 64 (95% CI 23-181). For conventional imaging, the pooled sensitivity was 0.70 (95% CI 0.57-0.81) and the pooled specificity was 0.96 (95% CI 0.88-0.98). LR syntheses yielded an overall LR+ of 16.1 (95% CI 5.8-44.5) and LR- of 0.31 (95% CI 0.21-0.46). The evaluated pooled DOR was 52 (95% CI 17-155).
CONCLUSION: 18F-FDG PET and conventional imaging demonstrated comparable diagnostic accuracies for the characterisation of cardiac masses. Further large multicentre studies are, however, required to corroborate the diagnostic performances of 18F-FDG PET and conventional imaging for the characterisation of cardiac masses. ADVANCES IN KNOWLEDGE: No previous studies have comprehensively analysed the diagnostic performance of 18F-FDG PET/CT compared with conventional imaging techniques including echocardiography, CT, and MRI. According to the current study, 18F-FDG PET/CT yielded a pooled DOR of 64, whereas other conventional imaging techniques demonstrated a DOR of 52. As such, 18F-FDG PET/CT demonstrated sensitivity and specificity, with a high pooled DOR comparable with other conventional imaging modalities.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 35612548     DOI: 10.1259/bjr.20210263

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  1 in total

Review 1.  Neuroimaging Modalities in Alzheimer's Disease: Diagnosis and Clinical Features.

Authors:  JunHyun Kim; Minhong Jeong; Wesley R Stiles; Hak Soo Choi
Journal:  Int J Mol Sci       Date:  2022-05-28       Impact factor: 6.208

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.