Size-Specific Dose Estimates for Thoracic and Abdominal Computed Tomography Examinations at Two Moroccan Hospitals.

M'hamed El Mansouri1, Abdelmajid Choukri2, Slimane Semghouli3, Mohammed Talbi4, Khalida Eddaoui5, Zouhir Saga6.   

Abstract

Size-specific dose estimates (SSDE) are the latest topic of interest in patient radiation-dose studies in computed tomography (CT). The aim of this study is to calculate and evaluate the doses (SSDE) by measuring the effective diameter (ED) of cross-sectional images collected during CT examinations of the chest and abdomen in Moroccan hospitals. Doses (SSDE) were calculated based on cross-sectional images by measuring the effective diameters of 75 patients in both examinations (45 for the thorax and 30 for the abdomen). Specific conversion factors for (ED) were used to convert the registered CTDIvol to SSDE, according to the instruction in the American Association of Physicists (AAPM) Report 204. In thoracic CT, the CTDIvol and SSDE values ranged from 5.8 to 10.7 mGy (mean: 8.08) and 9.55 to 15.37 mGy (mean: 12.13), respectively. For abdominal CT, CTDIvol and SSDE values ranged from 4.8 to 12.2 mGy (mean: 7.95) and 8.01 to 14.15 mGy (mean: 11.31), respectively. The results show that the SSDE is a useful tool and could potentially educate CT operators on its effective use as a way to optimize radiation dose instead of CTDIvol, in particular to establish diagnostic reference levels.
© 2022. The Author(s) under exclusive licence to Society for Imaging Informatics in Medicine.

Entities:  

Keywords:  CTDI; Computed tomography; Effective diameter (ED); Size-specific dose estimates (SSDE)

Year:  2022        PMID: 35610396     DOI: 10.1007/s10278-022-00657-0

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  1 in total

1.  Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT.

Authors:  Vishnukumar Rajaraman; Madhusudhanan Ponnusamy; Dhanapathi Halanaik
Journal:  Asia Ocean J Nucl Med Biol       Date:  2020