Literature DB >> 35608203

A leak-free head-out plethysmography system to accurately assess lung function in mice.

Stephanie Bruggink1,2, Kyle Kentch1, Jason Kronenfeld1, Benjamin J Renquist1,2.   

Abstract

Mice are a valuable model for elegant studies of complex, system-dependent diseases, including pulmonary diseases. Current tools to assess lung function in mice are either terminal or lack accuracy. We set out to develop a low-cost, accurate, head-out variable-pressure plethysmography system to allow for repeated, nonterminal measurements of lung function in mice. Current head-out plethysmography systems are limited by air leaks that prevent accurate measures of volume and flow. We designed an inflatable cuff that encompasses the mouse's neck preventing air leak. We wrote corresponding software to collect and analyze the data, remove movement artifacts, and automatically calibrate each dataset. This software calculates volume, inspiratory/expiratory time, breaths per minute, mid-expiratory flow, and end-inspiratory pause. To validate the use, we established that our plethysmography system accurately measured tidal breathing, the bronchoconstrictive response to methacholine, sex- and age-associated changes in breathing, and breathing changes associated with house dust mite sensitization. Our estimates of volume, flow, and timing of breaths are in line with published estimates, we observed dose-dependent decreases in volume and flow in response to methacholine (P < 0.05), increased lung volume, and decreased breathing rate with aging (P < 0.05), and that house dust mite sensitization decreased volume and flow (P < 0.05) while exacerbating the methacholine-induced increase in inspiratory time (P < 0.05). We describe an accurate, sensitive, low-cost, head-out plethysmography system that allows for longitudinal studies of pulmonary disease in mice.NEW & NOTEWORTHY We describe a low-cost, variable-pressure head-out plethysmography system that can be used to assess lung function in mice. A balloon cuff is inflated around the mouse's neck to prevent air leak, allowing for accurate measurements of lung volume and air flow. Custom software facilitates system calibration, removes movement artifacts, and eases data analysis. The system was validated by measuring tidal breathing, responses to methacholine, and changes associated with house dust mite sensitization, sex, and aging.

Entities:  

Keywords:  aging; bronchoconstriction; head-out plethysmography; lung function; mice

Mesh:

Substances:

Year:  2022        PMID: 35608203      PMCID: PMC9255710          DOI: 10.1152/japplphysiol.00835.2021

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  53 in total

1.  Pulmonary function assessment by whole-body plethysmography in restrained versus unrestrained mice.

Authors:  Michael P DeLorme; Owen R Moss
Journal:  J Pharmacol Toxicol Methods       Date:  2002 Jan-Feb       Impact factor: 1.950

2.  Assessing pulmonary pathology by detailed examination of respiratory function.

Authors:  Louis J Vaickus; Jacqueline Bouchard; Jiyoun Kim; Sudha Natarajan; Daniel G Remick
Journal:  Am J Pathol       Date:  2010-08-19       Impact factor: 4.307

3.  Effects of lung volume on lung and chest wall mechanics in rats.

Authors:  T Hirai; K A McKeown; R F Gomes; J H Bates
Journal:  J Appl Physiol (1985)       Date:  1999-01

4.  Sequential development of airway hyperresponsiveness and acute airway obstruction in a mouse model of allergic inflammation.

Authors:  U Neuhaus-Steinmetz; T Glaab; A Daser; A Braun; M Lommatzsch; U Herz; J Kips; Y Alarie; H Renz
Journal:  Int Arch Allergy Immunol       Date:  2000-01       Impact factor: 2.749

5.  Breathing pattern in asthma.

Authors:  M J Tobin; K Yang; D Upson
Journal:  Chest       Date:  1989-01       Impact factor: 9.410

6.  Assessment of airway response distribution and paradoxical airway dilation in mice during methacholine challenge.

Authors:  S Dubsky; G R Zosky; K Perks; C R Samarage; Y Henon; S B Hooper; A Fouras
Journal:  J Appl Physiol (1985)       Date:  2016-12-29

7.  Double-chamber plethysmography versus oscillometry to detect baseline airflow obstruction in a model of asthma in two mouse strains.

Authors:  Magali Boucher; Cyndi Henry; Fatemeh Khadangi; Alexis Dufour-Mailhot; Ynuk Bossé
Journal:  Exp Lung Res       Date:  2021-09-20       Impact factor: 2.459

8.  Unrestrained plethysmography is an unreliable measure of airway responsiveness in BALB/c and C57BL/6 mice.

Authors:  Andy Adler; Greg Cieslewicz; Charles G Irvin
Journal:  J Appl Physiol (1985)       Date:  2004-03-19

9.  Identifying discrete states of a biological system using a novel step detection algorithm.

Authors:  Jan Opfer; Kay-Eberhard Gottschalk
Journal:  PLoS One       Date:  2012-11-07       Impact factor: 3.240

10.  Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography.

Authors:  Samuel Mailhot-Larouche; Louis Deschênes; Katherine Lortie; Morgan Gazzola; David Marsolais; David Brunet; Annette Robichaud; Ynuk Bossé
Journal:  J Vis Exp       Date:  2018-07-10       Impact factor: 1.355

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.