Literature DB >> 35606251

Target Volume Coverage and Organ at Risk Doses for Left-sided Whole-breast Irradiation With or Without Internal Mammary Chain Irradiation: A Comparison Between Three Techniques Representing the Past and the Present.

S L C Bogers1, A L Petoukhova2, J J Penninkhof3, M E Mast4, P M Poortmans5, M S Hoogeman6, H Struikmans4.   

Abstract

AIMS: The 15-year results of the EORTC 229922-10925 phase III trial showed a significant reduction in breast cancer mortality and breast cancer recurrences after internal mammary chain (IMC) and medio-supraclavicular irradiation. Unexpectedly, cardiac death was not increased, and the incidence of cardiac events did not differ between left- and right-sided cases, although target volume coverages and organ at risk doses were unknown. Therefore, a planning study was carried out comparing the past and the present, to eventually enable, thereafter, an increased therapeutic ratio of IMC irradiation.
MATERIALS AND METHODS: A planning study was carried out on target volume coverage and organ at risk doses for whole-breast irradiation (WBI) ± IMC comparing the results between two-dimensional radiotherapy (free-breathing), hybrid intensity-modulated radiotherapy (IMRT; breath-hold) and robust intensity-modulated proton therapy (IMPT; free-breathing) for 10 left-sided breast cancer cases. Two-dimensional radiotherapy consisted of two tangential wedged photon breast fields and mixed electron/photon beams for the IMC. Hybrid IMRT included two tangential photon breast fields (70%) complemented with IMRT (30%). IMPT plans were created using multi-field robust optimisation (5 mm set-up and 3% range uncertainties) with two (WBI) or three (WBI + IMC) beams.
RESULTS: Target volume dose objectives were met for hybrid IMRT and IMPT. For two-dimensional radiotherapy, target coverage was 97% and 83% for breast and IMC, respectively. The mean heart dose for WBI only was <2 Gy for all techniques. For WBI + IMC, heart doses (mean heart dose, mean left anterior descending region, volume of the heart receiving 5 Gy (V5) were significantly higher for two-dimensional radiotherapy when compared with contemporary techniques. The V5 left anterior descending region reduced from 100% (two-dimensional radiotherapy) to 70% and 20% for hybrid IMRT and IMPT, respectively.
CONCLUSION: Contemporary radiotherapy techniques result in improved target volume coverage and significantly decreased heart doses for WBI + IMC radiotherapy. Hence, nowadays an increased therapeutic ratio of elective IMC irradiation may be anticipated.
Copyright © 2022 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Breast cancer; dosimetric comparison; hybrid IMRT; internal mammary chain; mixed electron/photon; robust IMPT

Mesh:

Year:  2022        PMID: 35606251     DOI: 10.1016/j.clon.2022.04.004

Source DB:  PubMed          Journal:  Clin Oncol (R Coll Radiol)        ISSN: 0936-6555            Impact factor:   4.925


  1 in total

Review 1.  Efficacy and Safety of the Addition of Internal Mammary Irradiation to Standard Adjuvant Radiation in Early-Stage Breast Cancer: A Systematic Review and Meta-Analysis.

Authors:  Yasmin Korzets; Dina Levitas; Ahuva Grubstein; Benjamin W Corn; Eitan Amir; Hadar Goldvaser
Journal:  Curr Oncol       Date:  2022-09-17       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.