Impedance and relative displacements of relaxed chest wall up to 4 Hz.

G M Barnas, K Yoshino, S H Loring, J Mead.   

Abstract

We measured the effective resistance (Reff) and elastance (Eeff) of the chest wall in four subjects, relaxed at functional residual capacity (FRC), during sinusoidal volume changes (5% vital capacity up to 4 Hz) delivered at the mouth. Subjects sat in a head-out body plethysmograph, and transthoracic pressure was measured with an esophageal balloon. Changes in Reff and in Eeff with frequency were nearly the same in all subjects. Reff (in cmH2O X l-1 X s) was 2.9 +/- 0.8 at 0.2 Hz and fell sharply to minimum values (0.5-0.9) at 1-4 Hz. Eeff (in cmH2O X l-1) increased from approximately 10 at the lowest frequency to a plateau of about 15 at 1-3 Hz and decreased above 3 Hz. In the same subjects, we measured the relative magnitude and phase between the displacements of different parts of the chest wall with magnetometers during identical sinusoidal forcing. Results indicate that the chest wall expands and deflates uniformly at frequencies up to 1 Hz. Thereafter the abdomen makes relatively larger excursions, and the relative magnitude and phase of displacement at different points on the chest wall show complex changes. We conclude that the frequency dependence of Reff and Eeff below 1 Hz is not due to nonuniformities in displacement of different parts of the chest wall. The frequency dependency of Reff is consistent with an increasing contribution of rate-independent plastic dissipation to the pressure difference in phase with flow as breathing frequency decreases.

Entities:  

Mesh:

Year:  1987        PMID: 3558198     DOI: 10.1152/jappl.1987.62.1.71

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  9 in total

1.  Determination of rate-constants as a method to describe passive expiration.

Authors:  Fabrizio Locchi; Gian-Luca Chelucci; Walter Araujo Zin
Journal:  Eur J Appl Physiol       Date:  2003-08-05       Impact factor: 3.078

2.  Mechanical impedance of the canine diaphragm. Part 2. Theoretical model and parameter estimation.

Authors:  B Suki; T Csendes; B Daróczy
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

Review 3.  Oscillation mechanics of the respiratory system: applications to lung disease.

Authors:  David W Kaczka; Raffaele L Dellacá
Journal:  Crit Rev Biomed Eng       Date:  2011

4.  A model of transient oscillatory pressure-flow relationships of canine airways.

Authors:  B Suki; B L Davey; J Sato; J H Bates
Journal:  Ann Biomed Eng       Date:  1995 Sep-Oct       Impact factor: 3.934

5.  Comparison of two methods of determining lung de-recruitment, using the forced oscillation technique.

Authors:  K Nilsen; K Gove; F Thien; T Wilkinson; B R Thompson
Journal:  Eur J Appl Physiol       Date:  2018-07-30       Impact factor: 3.078

6.  Reactance and elastance as measures of small airways response to bronchodilator in asthma.

Authors:  S A Bhatawadekar; D Leary; V de Lange; U Peters; S Fulton; P Hernandez; C McParland; G N Maksym
Journal:  J Appl Physiol (1985)       Date:  2019-10-24

7.  Helium-oxygen reduces work of breathing in mechanically ventilated patients with chronic obstructive pulmonary disease.

Authors:  Marc Gainnier; Jean-Michel Arnal; Patrick Gerbeaux; Stéphane Donati; Laurent Papazian; Jean-Marie Sainty
Journal:  Intensive Care Med       Date:  2003-07-25       Impact factor: 17.440

8.  Hyperpolarized 3He magnetic resonance imaging ventilation defects in asthma: relationship to airway mechanics.

Authors:  Del Leary; Sarah Svenningsen; Fumin Guo; Swati Bhatawadekar; Grace Parraga; Geoffrey N Maksym
Journal:  Physiol Rep       Date:  2016-04

9.  Testing limits to airflow perturbation device (APD) measurements.

Authors:  Erika R Lopresti; Arthur T Johnson; Frank C Koh; William H Scott; Shaya Jamshidi; Nischom K Silverman
Journal:  Biomed Eng Online       Date:  2008-10-31       Impact factor: 2.819

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.