| Literature DB >> 35564190 |
Barnabás Palcsó1, Adrienn Kazsoki1, Anna Herczegh2, Ágoston Ghidán3, Balázs Pinke4, László Mészáros4,5, Romána Zelkó1.
Abstract
BACKGROUND: Preventing infectious diseases has become particularly relevant in the past few years. Therefore, antiseptics that are harmless and insusceptible to microbial resistance mechanisms are desired in medicine and public health. In our recent work, a poly(ethylene oxide)-based nanofibrous mat loaded with sodium chlorite was formulated.Entities:
Keywords: antibacterial; chlorine dioxide; disinfection; electrospinning; nanofibers; poly(ethylene oxide); sodium chlorite
Year: 2022 PMID: 35564190 PMCID: PMC9104377 DOI: 10.3390/nano12091481
Source DB: PubMed Journal: Nanomaterials (Basel) ISSN: 2079-4991 Impact factor: 5.719
Figure 1Electrospinning setup and preparation of two samples of different weights for illustration.
Figure 2SEM images and histograms of the fiber diameter distribution of unloaded PEO (a) and NaClO2-loaded PEO (b) fibers.
Figure 3FTIR spectra of NaClO2-loaded PEO fibers (a), unloaded PEO fibers (b) and sodium chlorite (c).
Figure 4Chlorine dioxide production and chlorine dioxide production per weight of 1, 5, 10, 15, 20 and 30 mg samples.
Yield of generated ClO2 by samples of different weights calculated from the theoretical ClO2 production of sodium chlorite in acidic environment.
| msample (mg) | nNaClO2 (mmol) | c(ClO2)g (ppm) | c(ClO2)g | Yield (%) |
|---|---|---|---|---|
| 1 | 0.217 | 65.79 | 73.57 | 89.43 |
| 5 | 1.084 | 115.54 | 367.85 | 31.41 |
| 10 | 2.168 | 134.93 | 735.69 | 18.34 |
| 15 | 3.252 | 135.91 | 1103.54 | 12.32 |
| 20 | 4.336 | 141.16 | 1471.38 | 9.59 |
| 30 | 6.504 | 145.23 | 2207.07 | 6.58 |
1 Equations used to calculate the theoretical ClO2 concentration are shown in the Supplementary Materials.
Figure 5Effect of carbon dioxide concentration (a) and time (b) on ClO2-generating ability of 5 mg NaClO2-loaded PEO fibers.
Figure 6Experimental setup for bacterial inactivation study (a) and surviving colonies after incubation and counting (b) (S0: unloaded PEO fibers—control, S1: 1 mg NaClO2-loaded PEO, S2: 5 mg NaClO2-loaded PEO, S3: 10 mg NaClO2-loaded PEO fibers).
Figure 7Average surviving colonies per plate of control (S0) and NaClO2-loaded PEO fibers (S1: 1 mg, S2: 5 mg, S3: 10 mg).