| Literature DB >> 3554920 |
H A Ziessman, J Balseiro, F H Fahey, T V Le, V Dubiansky.
Abstract
Differential renal function was calculated by using 99mTc-glucoheptonate (Tc-GH) in 51 patients. Computer-acquired background-corrected individual renal function was calculated by using both the 1-3-min uptake counts and the 2-4-hr delayed static counts. The degree of correlation between the two was high (r = .96). An equally high correlation was noted in 16 children who were 12 years old or younger, in 15 patients with renal size disparity greater than 60/40%, and in six patients with abnormal creatinine clearances. Ten patients had a 30-min dynamic 99mTc-DTPA study followed immediately by the injection of Tc-GH and acquisition of delayed static images 2-4 hr later. A high degree of correlation (r = .99) was seen between the 1-3-min differential function obtained by using Tc-DTPA and the 2-4-hr delayed differential function obtained by using Tc-GH. This study shows that Tc-GH is a clinically useful and valid tool for calculation of differential renal function and that Tc-GH combines many of the best aspects of Tc-DTPA and Tc-DMSA.Entities:
Mesh:
Substances:
Year: 1987 PMID: 3554920 DOI: 10.2214/ajr.148.5.889
Source DB: PubMed Journal: AJR Am J Roentgenol ISSN: 0361-803X Impact factor: 3.959