Literature DB >> 3554776

[Detection of antibodies to HTLV-III: a comparison of various ELISA methods as screening tests and the Western Blot with immunofluorescence as confirmatory procedures].

P Hengster, C Larcher, E Pöckl, T Schulz, H Wachter, M P Dierich.   

Abstract

386 sera were examined with three commercially available ELISAs for antibodies to HTLV-III. Western Blot and an indirect immunofluorescence assay were performed on sera showing a positive reaction in one or more ELISAs as confirmatory assay. 299 sera reacted negatively in all ELISAs, 48 were positive in all ELISAs and the confirmatory assays, whilst 33 ELISA positive sera reacted negatively in the confirmatory assays. In the case of 5 sera both Western Blot as well as the immunofluorescence assay had to be undertaken to obtain conclusive results.

Mesh:

Substances:

Year:  1987        PMID: 3554776

Source DB:  PubMed          Journal:  Wien Klin Wochenschr        ISSN: 0043-5325            Impact factor:   1.704


  1 in total

1.  Comparison of Western blot (immunoblot) based on recombinant-derived p41 with conventional tests for serodiagnosis of human immunodeficiency virus infections.

Authors:  J M Hofbauer; T F Schulz; P Hengster; C Larcher; R Zangerle; H Kofler; P Fritsch; H Wachter; M P Dierich
Journal:  J Clin Microbiol       Date:  1988-01       Impact factor: 5.948