A sensitive electrochemical sensor based on ZIF-8-acetylene black-chitosan nanocomposites for rutin detection.

Ya-Feng Jin1,2, Chuang-Ye Ge2, Xiao-Bo Li2,3, Miao Zhang2, Guang-Ri Xu2, Dong-Hao Li1.   

Abstract

Herein, we fabricated a sensitive rutin electrochemical sensor via modifying glassy carbon electrode (GCE) with zeolitic imidazolate framework-8 (ZIF-8) and acetylene black (AB) in the presence of chitosan (CS). The electrochemical activity and experimental parameters of the ZIF-8-AB-CS/GCE sensor were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Under the optimal conditions, the sensor presented a reasonable linear response in the range of 0.1-10 μM with a limit of detection (LOD) as low as 0.004 μM (S/N = 3). The sensor possessed good reproducibility and high stability, and was successfully applied to detect rutin tablet samples with satisfactory results, which was attributed to the synergistic effect between ZIF-8 and AB. Meanwhile, the sensor displayed a potential application for detection of other analytes in real samples. Furthermore, a probable interaction mechanism was proposed to account for the interaction between rutin and the nanocomposite electrode, which was not discussed in previous reports. This journal is © The Royal Society of Chemistry.

Entities:  

Year:  2018        PMID: 35547678      PMCID: PMC9086340          DOI: 10.1039/c8ra06452k

Source DB:  PubMed          Journal:  RSC Adv        ISSN: 2046-2069            Impact factor:   3.361


Introduction

Rutin, also called vitamin P, is a common polyphenolic flavonoid which exists in some sources of vegetal origin, such as fruits, seeds, roots, flowers, tea, wine etc.[1] It has been widely applied in the health care system due to its prominent biological activity and pharmacological activity. Generally, rutin is used as an antioxidant and a nutrient enhancer in the human diet, and also as an inhibitor in some disease treatments, for example, as an anti-tumor, anti-hypertensive, anti-bacterial, anti-viral and anti-inflammatory agent. In particular, it can effectively adjust the penetrability of capillaries and stabilize blood platelets.[1,2] As a result, it is necessary to establish a sensitive, accurate and facile method for rutin detection in the field of clinical treatment, food nutrition research and pharmaceutical development. Till now, various analytical approaches have been established for rutin analysis, such as high performance liquid chromatography,[3] capillary electrophoresis,[4] sequential injection analysis,[5] chemiluminescence[6] and electrochemical analysis. However, most of them are time-consuming, expensive apparatus and complex operation are necessary as well. In contrast, electrochemical analysis possesses the merits of high sensitivity, low cost, and simple operation. Moreover, the hydroxyl groups in rutin are electro-active make it suitable to detect rutin by electrochemical technique. At present, diverse kinds of materials are employed to modify the electrode for the detection of rutin, including organic polymer,[7] ionic liquid,[8] metal and metal oxide nanoparticles[9,10] carbon nanomaterials[11-13] and their nanocomposites.[14-17] Among them, carbon nanomaterials have attracted tremendous attention due to their features such as good conductivity, high surface area and excellent chemical stability. Du et al.[11] developed grapheme nanosheets coated GCE to detect rutin with a LOD of 0.021 μM. Zeng et al.[12] prepared a single-walled carbon nanotubes modified gold electrode for rutin sensing and obtained a LOD of 0.01 μM. Song et al.[13] utilized AB nanoparticles in the present of dihexadecyl hydrogen phosphate (DHP) to modify GCE, and the LOD for rutin was 10 μg L−1. AB is one kind of carbon black materials with porous structure and has many promising properties such as excellent conductivity, high surface area and strong adsorption capacity. Generally, it serves as conductive agent in the field of energy storage and electrochemical sensors. To date, AB has been successfully applied for the development of modified electrodes to detect diverse species such as methimazole, oxytetracycline and bisphenol A.[18-20] Metal–organic frameworks (MOFs) are a new class of porous polymers, consisting of metal clusters and organic linkers, have been widely used in diverse fields, such as gas storage, heterogeneous catalysis, bioimaging, drug delivery, sample pretreatment and so on.[21-24] As a typical MOFs, ZIF-8 can be easily synthesized at room temperature with high specific surface area, good chemical stability. Nevertheless, the low conductivity of ZIF-8 confines its application in the field of electrochemical sensor. Up to now, there are rare reports on electroanalysis of rutin based on MOFs to modified electrode. And the mechanism of electrochemical determination of rutin at the nanomaterial modified interface of electrode and electrolyte has not been discussed. In this work, ZIF-8 nanocrystals were synthesized by solvothermal reaction firstly. A homogeneous dispersion was then prepared by mixing AB in CS aqueous solution. Finally, the above mentioned dispersion was drop-casted on the surface of GCE and dried for the further using. The sensor displays high sensitivity, good stability and reproducibility towards the oxidation and reduction of rutin. The excellent electrochemical performance of the sensor could be attributed to the synergistic effect between ZIF-8 and AB.

Experimental

Reagents

Zinc acetate dihydrate, 2-methylimidazole and chitosan were purchased from Shanghai Aladdin Biochemical Technology Co. Ltd, China. Rutin were purchased from Acros Organics (Shanghai, China). The stock standard solution was 1.0 mM rutin dissolved in anhydrous alcohol stored at 4 °C refrigerator, followed by diluted with 0.1 M phosphate buffer (pH 3) as required. Acetylene black was purchased from Shanghai chemical regent Co. Ltd, China. All the chemicals and regents are analytical grade and used without purification. All aqueous solutions were prepared with deionized water and all experiments were carried out at room temperature.

Instruments

All the electrochemical experiments were performed on a CHI 900 electrochemical workstation (Shanghai CH Instrument, China). A conventional three-electrode system with a glassy carbon electrode (GCE, diameter: 3.0 mm) as the work electrode, an Ag/AgCl electrode as reference electrode, and a platinum wire as a counter electrode. The scanning electron microscope (SEM) images were obtained in Merlin compact (ZEISS, Germany). X-ray diffraction (XRD) was determined using DX-2700B X-ray diffractometer (Shanghai Precision Instrument and Instrument Co. Ltd.).

Synthesis of ZIF-8

ZIF-8 nanoparticles were synthesized referred to the literature.[25] Firstly, zinc acetate (0.33 g) and 2-methylimidazole (0.985 g) were dissolved in 90 mL ethanol respectively. 2-Methylimidazole solution was then adding into zinc acetate solution with vigorous stirring. And the reaction was kept for 24 h at room temperature. Finally, the obtained white solution was centrifuged and washed with ethanol for three times, dried in vacuum at 60 °C overnight.

Fabrication of ZIF-8-AB-CS/GCE

The preparation process of ZIF-8-AB-CS/GCE was as follows. First of all, the GCE was polished with 0.05 μm Al2O3 paste and cleaned in ethanol and water by sonication, then dried at room temperature. Subsequently, 0.02 M acetic acid solution containing 1 mg mL−1 CS was prepared. And 2 mg ZIF-8/AB was added into 2 mL CS solution, followed by ultrasonic treatment for homogeneous dispersion. At last, 5 μL dispersion was dropped onto the surface of GCE with a syringe and dried under infrared lamp. The procedure of other materials modified GCE was carried out according to the statement above.

Results and discussion

Characterization of ZIF-8, AB and ZIF-8-AB

The XRD patterns of simulated ZIF-8, as-synthesized ZIF-8, AB and AB-ZIF-8 nanoparticles are shown in Fig. 1 respectively. The as-synthesized ZIF-8 exhibits obvious characteristic diffraction peak at 2θ values of 7.5°, 12.5° and 18°. And the crystal structure of as-synthesized ZIF-8 matches with the previous reported very well,[25] which demonstrates that we synthesized ZIF-8 successfully. AB displays their broad characteristic diffraction peak at 25.5°. ZIF-8-AB composition displayed strong diffraction peak at 2θ values of 7.5°, 12.5°, 18° and 25.5°. Which is in accordance with ZIF-8 and AB. What's more, the peaks becomes somewhat wider. This may be due to the AB particles covers the crystal structure of ZIF-8 partly.
Fig. 1

XRD patterns of simulated ZIF-8 (a), as-synthesized ZIF-8 (b), AB (c) and ZIF-8-AB (d).

To investigate the morphology structure of different modifiers, we examined four kinds of sensors via scanning electronic microscope. Fig. 2(a) shows the synthesized ZIF-8 is a typical rhombic dodecahedron with clear shape. This is quite in accordance with the previous report.[26] In addition, the size of ZIF-8 synthesized in our work is about 200 nm. The globular nanoparticles of AB is shown in Fig. 2(b), and the average diameter is about 30 nm. Fig. 2(c) shows the morphology for the composites of ZIF-8 and AB, we find that both ZIF-8 and AB are uniformly attached onto the surface of CS. The size of CS nanoplates are relatively bigger compared with ZIF-8 or AB, and the morphology of CS is shown in Fig. 2(d) with a smooth surface.
Fig. 2

SEM images of ZIF-8/GCE (a), AB-CS/GCE (b), ZIF-8-AB-CS/GCE (c) and CS/GCE (d).

Electrochemical behaviors of modified electrodes

The electrochemical behaviors of five different kinds of electrodes were studied by cyclic voltammetry (CV) in 50 μM rutin in the present of 0.1 M phosphate buffer solution (pH 3), as shown in Fig. 3(A). The oxidation peak potential (Epa) and reduction peak potential (Epc) are at 0.516 V and 0.503 V, respectively. The peak potential separation (ΔEp) of the ZIF-8-AB-CS/GCE is 13 mV, while the ΔEp values of the bare GCE, ZIF-8/GC, CS/GCE, and AB-CS/GCE are 26 mV, 40 mV, 24 mV, 15 mV respectively. The rate constant of electron transfer k0 increases with the decrease of ΔEp value for ferricyanide.[27] Thus, the order of k0 value of the five different electrodes was as follows: ZIF-8-AB-CS/GCE > AB-CS/GCE > CS/GCE > bare GCE > ZIF-8/GCE. Moreover, ZIF-8-AB-CS/GCE exhibits the highest redox peak current, and its oxidation peak current is about 2.5 times higher than that of bare GCE. There is a fast electron transfer rate at the interface between the ZIF-8-AB-CS/GCE surface and rutin, all these phenomena may attribute to the sensor has an ultrahigh surface and an excellent conductivity.
Fig. 3

CVs obtained in (A) 0.1 M PBS containing 50 μM rutin (pH 3) and EIS obtained in (B) 5 mM [Fe(CN)6]3−/4− (1 : 1) + 0.1 M KCl at five kinds of electrodes (a) ZIF-8/GCE, (b) bare GCE, (c) CS/GCE, (d) AB-CS/GCE, (e) ZIF-8-AB-CS/GCE. Scan rate: 100 mV s−1. Inset of (B) is the used equivalent circuit.

The electronic transfer kinetics of the five electrodes were also investigated via EIS measurement in 5 mM [Fe(CN)6]3−/4− solution with 0.1 M KCl as supporting electrolyte. The semicircle diameter values at higher frequencies stands for the electronic transfer resistance (Rct), and the linear part shows diffusion process at lower frequencies.[28] The equivalent circuit as shown in inset of Fig. 3(B). Rs stands for uncompensated solution resistance, Rct denoted charge transfer resistance arises from the electron transfer process, Cdl means double layer capacitance which formed by free movement of ions, Warburg impedance of Zw, generated by the mass transport process controlled by diffusion, was used to fit the impedance data.[29] By fitting the data using the equivalent circuit, we found that the Rct value at the ZIF-8/GCE (640 ohm) is the largest, Rct value at the ZIF-8-AB-CS/GCE (50 ohm) is the smallest. The order of Rct value of the five different electrodes is as follows: ZIF-8-AB-CS/GCE < AB-CS/GCE < CS/GCE < bare GCE < ZIF-8/GCE. It indicates that ZIF-8/GCE has a pretty poor conductivity that causes a low electron transfer rate at the ZIF-8/GCE. On the contrary, ZIF-8-AB-CS/GCE presents a quite fast electron transfer rate in [Fe(CN)6]3−/4− solution, which is also in accordance with the CV results.

Optimization of conditions

The effect of different mass ratio between ZIF-8 and AB on rutin redox reaction was investigated by CV. Fig. 4(A) shows the peak current gradually increases with the AB amount grows in the beginning. When the mass ratio is 1 : 5, the highest peak current is achieved. Afterwards, the peak current decreases while the AB amount increases continuously. The conductivity of the composite becomes better and better with the amount of AB increases, thus the rate of redox reaction proceeds fast at this time. However, the peak current decreases when the mass ratio is over 1 : 5, the reasons may be attributed to three aspects: on one hand, the aggregation of AB nanoparticles hinders electron transfer. On the other hand, the surface of ZIF-8 is covered by AB nanoparticles which may cause the loss of its catalytic activity. In addition, the penetration of solution will become difficult with the thickness of the surrounding AB increase. The synergistic effect mainly reflects in how to balance of the conductivity and the catalytic activity of composites. The electrode prepared at 1 : 5 is selected for the rest of experiments.
Fig. 4

(A) CVs of ZIF-8-AB-CS/GCE with different mass ratio ((a) 1 : 1, (b) 1 : 3, (c) 1 : 5, (d) 1 : 7, (e) 1 : 9) between ZIF-8 and AB in 0.1 M PBS containing 50 μM rutin (pH 4). Scan rate: 100 mV s−1. (B) CVs of ZIF-8-AB-CS/GCE at different pH (from right to left: 2, 2.5, 3, 4, 5, 6, 7, 8) under 50 μM rutin in 0.1 M PBS. Scan rate: 100 mV s−1. (C) The red line shows plots of Epavs. pH, and the black line shows plots of Ipavs. pH. (D) CVs of ZIF-8-AB-CS/GCE in 0.1 M PBS containing 50 μM rutin (pH 3) at various scan rates (from (a) to (k): 10, 30, 50, 80, 100, 150, 200, 250, 300, 400, 500 mV s−1). Insets: plots of anodic peak current and reductive peak current vs. scan rate.

The effect of pH on rutin detection at the sensor is shown in Fig. 4(B). It is noted that the redox peak current increases with pH value increases from 2 to 3. Subsequently, the redox peak currents shrink gradually when pH value is higher than 3. This can be explained by the varying of the amount of protons participating in the electrochemical redox of rutin in different pH conditions. In strong acid solution, there are so many of protons which is beneficial for the redox of ruin. The redox reaction becomes more difficult due to the continuously decreasing of the protons with the increasing of pH. The Fig. 4(C) displays that all of the redox peaks shift negatively as increasing of pH value. Moreover, the oxidation peak potential is liner response to pH value. The liner regression equation is as follows: Epa (V) = −0.0623pH + 0.7087 (R2 = 0.9786). The slope of the equation is 62 mV, which is close to the Nernst equation theoretical value of 59 mV, indicates that there are equal number of protons and electrons during the rutin redox reaction at the sensor.[30] In addition, the oxidation peak potential shifts more positively when pH value of 2. This may because the CS film becomes unstable partly in too much acidic environment, leading to a peeling-off of the ZIF-8-AB-CS composite. Considering the sensitivity of sensor, pH 3 was chosen for detection rutin in next experiment. The effect of scan rate on rutin redox at the modified sensor was studied by CV in the range of 10 mV s−1 to 500 mV s−1. Fig. 4(D) shows the redox peak current increases linearly with increasing scan rate. This implies that the redox of rutin is a quasi-reversible reaction.[30] Both oxidation peak current and reduction peak current are linear response to scan rate with the equations respectively: Ipa (μA) = 0.0590v (mV s−1) + 3.1831 (R2 = 0.9922), Ipc (μA) = −0.0508v (mV s−1) − 0.9873 (R2 = 0.9971). In other words, the redox peak current is in proportion to scan rate. Hence, it demonstrates that the behavior of rutin at the ZIF-8-AB-CS/GCE is an adsorption-controlled process. On the basis of the equation of Ipa = n2F2vAΓ*/4RT = nFQv/4RT,[30] the number of electron transfer n is about 2. Therefore, it manifests there are two protons and two electrons involved in the electrochemical redox reaction of rutin.

Possible interaction mechanism of rutin and ZIF-8-AB-CS/GCE

Scheme 1 shows the probable detection mechanism of rutin at the ZIF-8-AB-CS/GCE sensor. First of all, the π–π stacking interactions between the phenyl structures of rutin and the aromatic imidazole rings of ZIF-8, as well as the hexagonal carbonaceous rings of AB may contribute to the oxidation of rutin partially.[31] Secondly, the pK1 of rutin is about 7, thus rutin will become positively charged in the acidic environment.[32] The positively charged rutin could interact with ZIF-8 and AB easily via the cation–π interaction. Additionally, the hydrogen bonding interaction between Zn–N sites of ZIF-8 and the –OH groups of rutin also has the effect on the detection of rutin.[24] What's more, the conjugated aromatic rings in the molecular structure of rutin could also facilitate the electron transportation from rutin to the modified GCE.[7] Hence, the significant sensitivity enhancement for rutin detection could be assigned to the combined effect of all these interactions.
Scheme 1

Possible interaction mechanism of rutin and ZIF-8-AB-CS/GCE.

Quantitative determination of rutin

Under the optimal conditions, the determination of different concentrations of rutin at the ZIF-8-AB-CS/GCE sensor was examined by DPV. Fig. 5 shows that the peak current increases as the concentration of rutin increases. And the peak current presents linear relationship with rutin in the range of 0.1 μM to 10 μM. The linear equation can be expressed as: Ipa (μA) = 0.4569C (μM) − 0.1575 (R2 = 0.9969) with the LOD of 0.004 μM (S/N = 3). And the limit of quantitate (LOQ) is 0.013 μM (S/N = 10). Compared with the results from other analysis methods, the sensor exhibits a higher sensitivity than many other electrodes for rutin detection. The specific parameters are shown in Table 1.
Fig. 5

DPVs of ZIF-8-AB-CS/GCE in 0.1 M PBS containing different concentration (from (a) to (h): 0, 0.1, 1, 2, 4, 6, 8, 10 μM) of rutin solution. Scan rate: 100 mV s−1.

Comparison of different modified electrodes for rutin detection

ElectrodesMethodsLinear range (μM)LOD (μM)Reference
PAMAMa/graphene/GCEDPV0.001–20.0006 33
Graphene/GCEDPV0.1–20.023 34
MIPb/graphene-MWCNTsc/GCEDPV0.01–10.005 35
PdPcd-MWCNTs/GCEDPV0.1–510.075 36
CoFe2O4NPse/ILsf/CPEgDPV0.0001–0.010.00005 37
GOh-chitosan/GCESWVi0.9–900.56 38
ZIF-8-AB-CS/GCEDPV0.1–100.004This work

PAMAM: poly(amidoamine) dendrimers.

MIP: molecularly imprinted polymer.

MWCNTs: multiwalled carbon nanotubes.

PdPc: palladium phthalocyanine.

CoFe2O4NPs: nanoparticles.

ILs: ionic liquids.

CPE: carbon paste electrode.

GO: graphene oxide.

SWV: scan wave voltammograms.

PAMAM: poly(amidoamine) dendrimers. MIP: molecularly imprinted polymer. MWCNTs: multiwalled carbon nanotubes. PdPc: palladium phthalocyanine. CoFe2O4NPs: nanoparticles. ILs: ionic liquids. CPE: carbon paste electrode. GO: graphene oxide. SWV: scan wave voltammograms.

Selectivity, reproducibility, and stability

Selectivity of the sensor is an important property of the whole determination method. To investigate the selectivity of the sensor, some inorganic compounds and organic compounds are chosen as interference. CuCl, FeSO4, KNO3, NaCl, VB2, tyrosine (Tyro), tryptophan (Tryp) were added to 5 μM rutin, respectively. The concentration of inorganic compounds or organic compounds were 100-fold of rutin. The results are shown in Fig. S1 and Table S1.† It manifests that the sensor has a high selectivity. And the relative error deviation is less than 5%. Further, we studied the reproducibility and stability of the sensor. The reproducibility experiment was executed via scanning 20 circles successively with CV at the ZIF-8-AB-CS/GCE in 50 μM rutin solution (pH 3). The RSD of the same sensor is 0.6–1.0%, and the RSD for sensor to sensor (N = 5) is 2.5–3.6% in the same day. Finally, we stored the sensor in refrigerator for 120 hours and studied its long-term stability. The peak current value is about 85% of initial current value (RSD = 3.0%, N = 3). The results indicates that the sensor has a good stability.

Real sample analysis

To evaluate the practicality of the developed method, we purchased rutin tablets (20 mg per tablet) from local pharmacy. Firstly, three tablets were accurately weighed and then grounded into fine powder respectively. Then, the powder was dissolved into 10 mL ethanol by sonication. Next, 0.025 mL, 0.05 mL and 0.1 mL dispersion were transferred into 50 mL volumetric flask and diluted with 0.1 M PBS (pH 3) to volume respectively. At last, the concentration of the diluted rutin solution was detected by DPV at same electrode and calculated with the linear equation in section of 3.5. Table S2† shows the recoveries of four parallel samples are 96.0–104.6%. It demonstrates the proposed method based on the ZIF-8-AB-CS/GCE has a quite good accuracy and practical applicability.

Conclusions

In summary, a sensitive and simple electrochemical sensor based on ZIF-8-AB-CS was successfully fabricated towards rutin determination. ZIF-8-AB-CS/GCE exhibits more excellent electrochemical performance than ZIF-8-CS/GCE and AB-CS/GCE. This phenomenon may due to the synergistic effect between ZIF-8 and AB. Meanwhile, the results shows that the sensor has good selectivity, reproducibility, stability and recoveries from the real samples. Moreover, the sensor has a potential application for the electrochemical sensing of other targets. The approach of sensor fabrication also could be used to construct other types of sensors.

Conflicts of interest

There are no conflicts to declare.
  17 in total

1.  Exceptional chemical and thermal stability of zeolitic imidazolate frameworks.

Authors:  Kyo Sung Park; Zheng Ni; Adrien P Côté; Jae Yong Choi; Rudan Huang; Fernando J Uribe-Romo; Hee K Chae; Michael O'Keeffe; Omar M Yaghi
Journal:  Proc Natl Acad Sci U S A       Date:  2006-06-23       Impact factor: 11.205

2.  Sensitive voltammetric determination of rutin at an ionic liquid modified carbon paste electrode.

Authors:  Ya Zhang; Jianbin Zheng
Journal:  Talanta       Date:  2008-07-01       Impact factor: 6.057

3.  Electrochemical determination of methimazole based on the acetylene black/chitosan film electrode and its application to rat serum samples.

Authors:  Wang Yazhen
Journal:  Bioelectrochemistry       Date:  2011-04-21       Impact factor: 5.373

4.  Red-emitting BSA-stabilized copper nanoclusters acted as a sensitive probe for fluorescence sensing and visual imaging detection of rutin.

Authors:  Benqian Wang; Rijun Gui; Hui Jin; Weijie He; Zonghua Wang
Journal:  Talanta       Date:  2017-09-01       Impact factor: 6.057

5.  Simultaneous HPLC determination of flavonoids and phenolic acids profile in Pêra-Rio orange juice.

Authors:  E Mesquita; M Monteiro
Journal:  Food Res Int       Date:  2017-12-14       Impact factor: 6.475

Review 6.  Rutin : therapeutic potential and recent advances in drug delivery.

Authors:  Shrestha Sharma; Asgar Ali; Javed Ali; Jasjeet K Sahni; Sanjula Baboota
Journal:  Expert Opin Investig Drugs       Date:  2013-06-25       Impact factor: 6.206

7.  Facile preparation of molecularly imprinted polypyrrole-graphene-multiwalled carbon nanotubes composite film modified electrode for rutin sensing.

Authors:  Lite Yang; Juan Yang; Bingjie Xu; Faqiong Zhao; Baizhao Zeng
Journal:  Talanta       Date:  2016-08-31       Impact factor: 6.057

8.  Naturally occurring polyphenolic antioxidants modulate IgE-mediated mast cell activation.

Authors:  S Chen; J Gong; F Liu; U Mohammed
Journal:  Immunology       Date:  2000-08       Impact factor: 7.397

9.  Simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid based on nitrogen doped porous carbon nanopolyhedra.

Authors:  Pengbo Gai; Hejing Zhang; Yunsong Zhang; Wei Liu; Gangbing Zhu; Xiaohua Zhang; Jinhua Chen
Journal:  J Mater Chem B       Date:  2013-04-25       Impact factor: 6.331

10.  Metal-organic framework UiO-66 coated stainless steel fiber for solid-phase microextraction of phenols in water samples.

Authors:  Hai-Bo Shang; Cheng-Xiong Yang; Xiu-Ping Yan
Journal:  J Chromatogr A       Date:  2014-05-17       Impact factor: 4.759

View more
  1 in total

Review 1.  Engineering the ZIF-8 Pore for Electrochemical Sensor Applications-A Mini Review.

Authors:  Anirban Paul; Ivneet Kaur Banga; Sriram Muthukumar; Shalini Prasad
Journal:  ACS Omega       Date:  2022-07-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.