| Literature DB >> 35542213 |
Michal Maryška1,2, Lucie Fojtíková1,3, Radek Jurok4,2, Barbora Holubová3, Oldřich Lapčík1, Martin Kuchař1,2.
Abstract
Tryptamines are a group of hallucinogenic drugs whose detection in body fluids could be simplified by immunochemical assay kits. Antibodies for these assays are obtained by the immunization of laboratory animals with conjugates of a hapten similar to the target analyte and a suitable protein. Therefore we synthesized novel haptens derived from tryptamine-based drugs, with N,N-dimethyltryptamine (DMT), 5-methoxy-N,N-dimethyltryptamine (5-MeO-DMT) and N,N-diisopropyltryptamine (DiPT) selected as the target analytes. Their structures were modified with a short linker ended with a carboxylic group. The haptens were conjugated with bovine serum albumin (BSA) and rabbits were immunized with the conjugates. The obtained polyclonal antibodies showed good reactivity and the LOD of the constructed ELISAs was in the range 0.006-0.254 ng mL-1. Thus, they are suitable for the development of immunochemical assay kits. This journal is © The Royal Society of Chemistry.Entities:
Year: 2018 PMID: 35542213 PMCID: PMC9080274 DOI: 10.1039/c8ra02528b
Source DB: PubMed Journal: RSC Adv ISSN: 2046-2069 Impact factor: 4.036
Fig. 1Designed haptens I–IV.
Fig. 2Synthesis of hapten I.
Fig. 3Direct synthesis of haptens II–IV using Fischer reaction.
Fig. 4Preparation of N,N-dimethylamino-1,1-dimethoxybutane (9).
Fig. 5Synthesis of N,N-diisopropylamino-1,1-dimethoxybutane (10).
Fig. 6Typical ELISA standard curves (◆) ELISA I (standard DMT); (▲) ELISA II (standard 5-MeO-DMT); (▬) ELISA III (standard 5-MeO-DMT); (■) ELISA IV (standard DiPT).
Analytical parameters of assembled ELISAs
| IC50 | Linear working range (ng ml−1) | LOD | |
|---|---|---|---|
| ELISA I | 0.52 ± 0.17 | 0.11–4.24 | 0.017 ± 0.005 |
| ELISA II | 27.3 ± 5.20 | 4.08–241.96 | 0.254 ± 0.059 |
| ELISA III | 0.29 ± 0.07 | 0.03–4.93 | 0.006 ± 0.002 |
| ELISA IV | 3.36 ± 0.28 | 0.27–45.13 | 0.034 ± 0.005 |
IC50, 50% intercept.
SD, standard deviation.
LOD, limit of detection.
Cross-reactivity data for developed ELISAa
| Compound | Cross-reactivity (%) | |||
|---|---|---|---|---|
| ELISA I | ELISA II | ELISA III | ELISA IV | |
| DMT | 100.00 | 53.48 | 38.89 | 0.09 |
| 5-MeO-DMT | 0.57 | 100.00 | 100.00 | 0.04 |
| 5-MeO-DALT | 1.90 | 0.95 | 2.46 | 0.19 |
| DiPT | 2.00 | 0.09 | 0.21 | 100.00 |
| 4-HO-MET | 2.16 | 5.87 | 20.08 | 0.05 |
| αMT | 0.14 | 0.07 | 0.04 | <0.001 |
|
| 0.06 | 2.81 | 23.04 | <0.001 |
| Psilocin | 3.60 | 225.71 | 149.63 | 0.10 |
| Psilocybin | <0.001 | 0.07 | 0.08 | <0.001 |
| Serotonin | <0.001 | <0.001 | <0.001 | <0.001 |
| 5-MeO-DiPT | 0.01 | <0.001 | 0.43 | 88.43 |
DMT: N,N-dimethyltryptamine, 5-MeO-DMT: 5-methoxy-N,N-dimethyltryptamine, 5-MeO-DALT: N,N-diallyl-5-methoxytryptamine, DiPT: N,N-diisopropyltryptamine, 4-HO-MET: 4-hydroxy-N-methyl-N-ethyltryptamine, αMT: α-methyltryptamine, 5-MeO-DiPT: 5-methoxy-N,N-diisopropyltryptamine.