Literature DB >> 35537942

Inferior vena cava ultrasonography before general anesthesia cannot predict arterial hypotension in patients undergoing vascular surgery.

L Turconi1, F Cavalleri2, L G Moreno3, M Surbano1, L Illescas4, J P Bouchacourt5, E Kohn5, G Ferrari6, J Riva7.   

Abstract

INTRODUCTION: Intraoperative hypotension (IH) is an independent predictor of mortality. Some experts have suggested that ultrasound measurement of the inferior vena cava (IVC) in spontaneous ventilation can predict IH.
OBJECTIVE: To evaluate the capacity of ultrasound measures of IVC in spontaneous ventilation to predict episodes of IH after anaesthesia induction. PATIENTS AND METHODS: We studied 55 high-risk cardiac patients undergoing vascular surgery. The maximum (dIVCmax) and minimum (dIVCmin) diameter of the IVC were measured and the collapsibility index CI = (dIVCmax-dIVCmin)/dIVCmax was calculated prior to anaesthesia induction. Three definitions of IH were used: systolic blood pressure (SBP) less than 100 mmHg, mean arterial pressure (MAP) less than 60 mmHg, and a decrease in MAP greater than or equal to 30% compared to baseline.
RESULTS: There were no significant differences in dIVCmax or in CI between patients presenting IH after anaesthesia induction and those who did not. ROC curves for dIVCmax showed an area under the curve of 0.55 (0.39-0.70), 0.69 (0.48-0.90), and 0.57 (0.42-0.73) and ROC curves for the CI were 0.62 (0.47-0.78), 0.60 (0.41-0.78) and 0.62 (0.47-0.78) for the 3 definitions of IH (<100 mmHg, MAP < 60 mmHg, and MAP ≥30% baseline), respectively.
CONCLUSIONS: Ultrasound measurements of IVC in spontaneous ventilation are not good predictors of IH after anaesthesia induction in these patients. The optimal cut-off points show low specificity and moderate sensitivity for predicting IH.
Copyright © 2021 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Anaesthesia induction; Factores de riesgo; Hipotensión; Hypotension; Inducción anestésica; Inferior vena cava; Predictores; Predictors; Risk factors; Vena cava inferior

Mesh:

Year:  2022        PMID: 35537942     DOI: 10.1016/j.redare.2021.03.013

Source DB:  PubMed          Journal:  Rev Esp Anestesiol Reanim (Engl Ed)        ISSN: 2341-1929


  1 in total

1.  Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study.

Authors:  Hanying Zhang; Hongguang Gao; Yuanjun Xiang; Junxiang Li
Journal:  Front Cardiovasc Med       Date:  2022-10-04
  1 in total