Literature DB >> 35536373

Incisional hernia repair with a slowly absorbable P4HB mesh: what happens after the mesh disappears? A retrospective longitudinal clinical study.

T Layer1, S Benammi1, V Dubuisson2, S Manfredelli1,3, G Passot4,5, D Charleux-Muller1, Y Renard6, P Ortega-Deballon7, B Romain8,9.   

Abstract

PURPOSE: To analyze the incisional hernia recurrence rate at a long-term follow-up using a biosynthetic long-term absorbable mesh in patients with a higher risk of surgical infection in a contaminated surgical field.
METHODS: This was a retrospective multicentric study. All patients undergoing incisional hernia repair between 2016 and 2018 at 6 participating university centers were included. Patients were classified according to the Ventral Hernia Working Group (VHWG). All consecutive patients who underwent abdominal wall repair using biosynthetic long-term absorbable mesh (Phasix®) in contaminated fields (grade 3 and 4 of the VHWG classification) were included. Patients were followed-up until September 2021. Preoperative, operative, and postoperative data were collected. All patients' surgical site infections (SSIs) and surgical site occurrences (SSOs) were recorded. The primary outcome of interest was the clinical incisional hernia recurrence rate.
RESULTS: One hundred and eight patients were included: 77 with VHWG grade 3 (71.3%) and 31 with VHWG grade 4 (28.7%). Median time follow-up was 41 months [24; 63]. Twenty-four patients had clinical recurrence during the follow-up (22.2%). The SSI and SSO rates were 24.1% and 36.1%, respectively. On multivariate analysis, risk factors for incisional hernia recurrence were previous recurrence, mesh location, and postoperative enterocutaneous fistula.
CONCLUSIONS: At the 3 year follow-up, the recurrence rate with a biosynthetic absorbable mesh (Phasix®) for incisional hernia repair in high-risk patients (VHWG grade 3 and 4) seemed to be suitable (22.2%). Most complications occurred in the first year, and SSI and SSO rates were low despite high-risk VHWG grading.
© 2022. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.

Entities:  

Keywords:  Biosynthetic mesh; Contaminated surgery; Incisional hernia repair; Recurrence

Year:  2022        PMID: 35536373     DOI: 10.1007/s10029-022-02616-8

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  1 in total

1.  How Long Do We Need to Follow-Up Our Hernia Patients to Find the Real Recurrence Rate?

Authors:  Ferdinand Köckerling; Andreas Koch; Ralph Lorenz; Christine Schug-Pass; Bernd Stechemesser; Wolfgang Reinpold
Journal:  Front Surg       Date:  2015-06-16
  1 in total
  1 in total

1.  Shifting the Goalpost in Ventral Hernia Care: 5-year Outcomes after Ventral Hernia Repair with Poly-4-hydroxybutyrate Mesh.

Authors:  Ankoor A Talwar; Nikhita J Perry; Phoebe B McAuliffe; Abhishek A Desai; Sheri Thrippleton; Robyn B Broach; John P Fischer
Journal:  Hernia       Date:  2022-09-16       Impact factor: 2.920

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.