Literature DB >> 3552689

Estimation of glomerular filtration rate using 99mTc-DTPA and the gamma camera.

C D Russell.   

Abstract

Two methods of glomerular filtration rate estimation have been evaluated, based on the intravenous administration of 99mTc-DTPA and the measurement of renal time activity curves by means of a computer linked gamma camera. A single 20 min plasma sample was also required. These methods were designed to minimize the component of error arising from decay statistics. One method was based on using a constant fraction of the cardiac activity in lieu of a perirenal region of interest for the background correction, the other was based on deconvolution by a constrained least squares technique. The first method, based on modifying the background correction, led to poor results (residual standard deviation 18.9 ml/min when compared with the plasma clearance method). The second method, based on constrained least squares deconvolution, worked as well as previously reported methods (residual standard deviation 14.5 ml/min) and appears suitable for clinical use.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3552689     DOI: 10.1007/BF00296095

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  3 in total

1.  An improved deconvolution technique for the calculation of renal retention functions.

Authors:  A Kuruc; W J Caldicott; S Treves
Journal:  Comput Biomed Res       Date:  1982-02

2.  Measurement of glomerular filtration rate using 99mTc-DTPA and the gamma camera: a comparison of methods.

Authors:  C D Russell; P G Bischoff; F Kontzen; K L Rowell; M V Yester; L K Lloyd; W N Tauxe; E V Dubovsky
Journal:  Eur J Nucl Med       Date:  1985

3.  99mTc-DTPA gamma-camera renography: normal values and rapid determination of single-kidney glomerular filtration rate.

Authors:  M Rehling; M L Møller; J O Lund; K B Jensen; B Thamdrup; J Trap-Jensen
Journal:  Eur J Nucl Med       Date:  1985
  3 in total
  3 in total

1.  Comparison of glomerular filtration rate measured by plasma sample technique, Cockroft Gault method and Gates' method in voluntary kidney donors and renal transplant recipients.

Authors:  Julie Hephzibah; Nylla Shanthly; Regi Oommen
Journal:  Indian J Nucl Med       Date:  2013-07

2.  Comparison between Two-sample Method with 99mTc-diethylenetriaminepentaacetic acid, Gates' Method and Estimated Glomerular Filtration Rate Values by Formula Based Methods in Healthy Kidney Donor Population.

Authors:  Manish Kumar; Geetanjali Arora; Nishikant Avinash Damle; Praveen Kumar; Madhavi Tripathi; Chandrasekhar Bal; Sameer Kamlakar Taywade; Abhinav Singhal
Journal:  Indian J Nucl Med       Date:  2017 Jul-Sep

3.  Impact of Body Mass Index on Gates Method of Glomerular Filtration Rate Estimation: A Comparative Study with Single Plasma Sample Method.

Authors:  Amit Nautiyal; Anirban Mukherjee; Deepanjan Mitra; Piyali Chatterjee; Anindya Roy
Journal:  Indian J Nucl Med       Date:  2019 Jan-Mar
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.