Literature DB >> 3552666

Lysis centrifugation and slide blood culture systems for diagnosis of bacteremia in immunocompromised patients.

H Richet, M C Escande, P H Lagrange.   

Abstract

Compared with a slide blood culture system, a lysis centrifugation system detected significantly more positive blood cultures and more episodes of bacteremia in immunocompromised patients (even when on antibiotics), while giving results more rapidly and even at significantly lower CFUs. However, it had a high contamination rate and did not detect Pseudomonas aeruginosa as often. Use of the two systems together is recommended for diagnosing bacteremia early in immunocompromised patients.

Entities:  

Mesh:

Year:  1987        PMID: 3552666     DOI: 10.1007/BF02097197

Source DB:  PubMed          Journal:  Eur J Clin Microbiol        ISSN: 0722-2211            Impact factor:   3.267


  8 in total

1.  Use of quantitative bacteriologic techniques to diagnose catheter-related sepsis.

Authors:  E J Wing; C W Norden; R K Shadduck; A Winkelstein
Journal:  Arch Intern Med       Date:  1979-04

2.  Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood.

Authors:  J Bille; L Stockman; G D Roberts; C D Horstmeier; D M Ilstrup
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

3.  Comparison of lysis-centrifugation with a biphasic blood culture medium for the recovery of aerobic and facultatively anaerobic bacteria.

Authors:  N K Henry; C M Grewell; P E Van Grevenhof; D M Ilstrup; J A Washington
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

4.  Clinical laboratory comparison of lysis-centrifugation and BACTEC radiometric blood culture techniques.

Authors:  J C McLaughlin; P Hamilton; J V Scholes; R C Bartlett
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

5.  Evaluation of a lysis-centrifugation and biphasic bottle blood culture system during routine use.

Authors:  M T Kelly; G E Buck; M F Fojtasek
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

6.  Detection of bacteremia in leukemic patients by early subcultures with a slide blood culture system.

Authors:  H Richet; R Gerbal; B Hautefort; R Chataigne; P H Lagrange
Journal:  Pathol Biol (Paris)       Date:  1985-03

7.  Improved blood culture technique based on centrifugation: clinical evaluation.

Authors:  G L Dorn; G A Land; G E Wilson
Journal:  J Clin Microbiol       Date:  1979-03       Impact factor: 5.948

8.  Comparative recovery of bacteria and yeasts from lysis-centrifugation and a conventional blood culture system.

Authors:  T E Kiehn; B Wong; F F Edwards; D Armstrong
Journal:  J Clin Microbiol       Date:  1983-08       Impact factor: 5.948

  8 in total
  1 in total

Review 1.  Contamination of blood cultures during venepuncture: fact or myth?

Authors:  E Shahar; B S Wohl-Gottesman; L Shenkman
Journal:  Postgrad Med J       Date:  1990-12       Impact factor: 2.401

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.