Abstract
Fluorescent immunosorbent assay (FIA) is very promising for sensitive and selective analysis in bio-medical applications. Here, we proposed an assay, using fluorescent engineering of analytes and the corresponding molecularly imprinted polymers (MIPs) as a plastic antibody. Three drug molecules (metronidazole, zidovudine and lamivudine) were condensed with 9-aminoacridine, using succinic anhydride as a spacer. The target products were characterized with 1H-NMR, IR and mass spectrometry. UV-vis absorption and fluorescent properties of the fluorophore-labeled drug molecules were investigated. Feasibility of the fluorescent biomimetic immunosorbent assay based on MIPs was demonstrated in the solution. This work will provide sound foundation for the future application in real sample. This journal is © The Royal Society of Chemistry.Entities:
Year: 2019 PMID: 35518505 PMCID: PMC9061092 DOI: 10.1039/c9ra00422j
Source DB: PubMed Journal: RSC Adv ISSN: 2046-2069 Impact factor: 3.361
Scheme 1(A) Fluorescent labelled drug molecules, MNZ-F, AZT-F and 3TC-F; (B) synthetic route of the fluorescence labelling process (a) pyridine or anhydrous acetone, rt, stir 24 h; (b) anhydrous acetone or anhydrous dimethylformamide (DMF), dimethylaminopyridine (DMAP), N,N-dicyclohexylcarbodiimide (DCC), rt, stir 36 h; (c) anhydrous DMF, DMAP, rt, stir 36 h.
Fig. 1(A) Fluorescence excitation (EX) and emission (EM) spectra of MNZ-F in methanol solution; (B) fluorescence emission spectra of MNZ-F in various solvents. (λex = 366 nm, sensitivity of 2, slit width of 10/10 nm).
Relative fluorescence quantum yields
| Compound | Solvent | Refractive index | Gradient (×10–5) | Relative quantum yield |
|---|---|---|---|---|
| Quinine sulfate | 0.1 M H2SO4 | 1.333 | 6.56 | 0.547 |
| 9-AA | Ethanol | 1.362 | 4.56 | 0.397 |
| MNZ-F | Water | 1.333 | 4.44 | 0.370 |
| AZT-F | Water | 1.333 | 6.76 | 0.564 |
| 3TC-F | Water | 1.333 | 3.01 | 0.251 |
Calibration curve parameters
| Labeled drug | Regression equation | Linear range (mmol) |
| Solvent |
|---|---|---|---|---|
| MNZ-F |
| 0.006–0.18 | 0.9394 | Methane chloride |
| AZT-F |
| 0.01–0.20 | 0.9975 | Acetonitrile |
| 3TC-F |
| 0.01–0.20 | 0.9887 | Acetonitrile |
Scheme 2Principle of the fluorescent biomimetic immunosorbent assay. MIPs: molecularly imprinted polymers (plastic antibody).
Fig. 2(A) Fluorescence spectra of competitive binding assay of 0.018 mM MNZ-F in the presence of 0–0.36 mM MNZ (λex = 395 nm, sensitivity of 2, slit width of 20/10 nm) in chloroform solution; (B) relationship between fluorescence intensity and concentration of MNZ.