P Abdul Rasheed1, Ravi P Pandey1, Tricia Gomez1, Michael Naguib2, Khaled A Mahmoud1. 1. Qatar Environment and Energy Research Institute (QEERI), Hamad Bin Khalifa University (HBKU), Qatar Foundation P. O. Box 34110 Doha Qatar kmahmoud@hbku.edu.qa. 2. Department of Physics and Engineering Physics, Tulane University New Orleans LA USA.
Lead (Pb) is a common heavy metal, used in a variety of industrial processes and anthropogenic activities.[1] Pb2+ ions are known for their extremely harmful biological toxicity through enzyme inhibition and induction of oxidative stress and can cause chronic damage to several human body systems, including kidneys, gastrointestinal system, nervous system, and reproductive system.[2-4] Moreover, Pb contamination poses a serious health and environmental hazard due to its high accumulation and low clearance rate at contaminated sites.[5,6] The maximum level of Pb2+ in drinking water set by the United States Environmental Protection Agency (EPA) is 15 μg L−1 (72 nM),[7] while the World Health Organization (WHO) limit for the blood Pb2+ level is 100 μg L−1 (483 nM).[5,8]Various techniques are used for the detection of Pb2+ in water including atomic absorption/fluorescence spectrometry, optical emission spectrometry, inductively coupled plasma mass spectrometry, and chemical or optical sensors.[9-11] Despite their reliability, the operations and maintenance associated with these methods are tedious, costly, and not suitable for on-site monitoring. Electrochemical techniques are inexpensive, selective, highly sensitive and effective alternative for the detection of various toxic substances and heavy metals.[12-14] Moreover, electrochemical methods are characterized by their portability, easy operation, quick analysis time, and low maintenance and instrumentation costs.[8,15] Stripping voltammetry (especially anodic stripping) have been used as the sensitive and powerful electrochemical technique for the detection of heavy metal ions.[1,9] Different carbon nanomaterials such as carbon nanotubes, graphene, and its composite materials have been used as the sensing platform for sensitive Pb2+ detection.[16-20]The 2D transition metal carbides and carbonitrides (MXenes) have attracted broad attention with unique physicochemical properties.[21-24] The large lateral size with few nanometer thickness, embedded with good hydrophilicity, and activated metallic hydroxide sites render MXenes as promising materials for environmental remediation applications.[25-28] MXene surfaces is negatively charged due to its surface functional groups, which facilitate the adsorption of several toxic heavy metals and emerging contaminants.[27,29] In addition, MXenes nanosheets having strong trapping power to small cations, due to less inter planner distance (<2 Å).[30] It was reported that Ti3C2T which is the most studied MXene, is an efficient adsorbent for the gold, lead and chromium cations.[30] In addition, the intercalation of different cations with various sizes and charges are possible between Ti3C2T layers.[30] After alkalization intercalation of Ti3C2T, alk-MXene (Ti3C2(OH/ONa)F2−) exhibits superior sorption behavior for Pb2+ in presence of high levels of interfering cations such as Ca2+ and Mg2+.[31] Recently, alkalization-intercalated Ti3C2T modified electrode displayed enhanced electrochemical response towards the detection of Cd2+, Pb2+, Cu2+ and Hg2+.[32] The alkalization process increases the c lattice parameter of Ti3C2T from 19.741 Å to 26.187 Å and the alkalization process results in unique morphology and alteration in surface chemistry. This leads to enhanced electrochemical responses for alkalization-intercalated Ti3C2T towards the heavy metal detection in comparison with the Ti3C2T.Nb4C3T is another member of the MXenes family, prepared by etching of Al from the Nb4AlC3 MAX phase.[33,34] Recently, Nb4C3T have been explored in a number of applications, including dye adsorption,[35] energy storage devices,[23,36-38] hematopoietic recovery,[33] photothermal tumor eradication,[22] supercapacitors,[39] and photocatalytic hydrogen production.[40] Even though, the electrochemical performance of Nb4C3T has not been widely explored towards sensing applications.In this paper, we evaluate the electrochemical performance of Nb2CT and Nb4C3T on the glassy carbon electrode (GCE) and their application as sensing platform for the detection of Pb2+ in the aqueous media. To the best of our knowledge, this is the first report discusses the application of Nb4C3T as electrochemical sensor for heavy metals.
Experimental
Materials
Phosphate buffer (PB) solution, NaOH, H2SO4, K3[Fe(CN)6], K4[Fe(CN)6]·3H2O, sodium acetate, acetic acid, lead nitrate, copper sulfate and cadmium acetate were purchased from Sigma Aldrich. The MAX phases of Nb2CT and Nb4C3T (Nb2AlC and Nb4AlC3 respectively) were prepared by mixing powders of niobium (Alfa Aesar, 99.98%, −325 mesh), aluminum (Alfa Aesar, 99.9%, −325 mesh), and carbon (Alfa Aesar, 99%, 7–11 micron) at different ratios, followed by heating under an argon (Ar) flow. The detailed procedure is given in the ESI† and in the ref. 34 and 37.
Synthesis of Nb2CT and Nb4C3T
The synthesis of multilayered Nb2CT (ML-Nb2CT) and Nb4C3T (ML-Nb4C3T) MXenes were done by hydrofluoric acid (HF) etching of Al layers from MAX phases Nb2AlC and Nb4AlC3 respectively. The Nb2AlC or Nb4AlC3 powders were stirred for 96 h at 40 °C after immersing in 50% HF aqueous solution. The resulting reaction mixture were washed 5 to 6 times using DI water and centrifuged at 3500 rpm to separate the ML-MXenes as settled powders from the supernatants. The resulting ML-MXenes were washed using ethanol, and dried at 30 °C under flow of argon. The delaminated Nb2CT (DL-Nb2CT) and Nb4C3T MXenes (DL-Nb4C3T) flakes were prepared by probe sonication (Cole Parmer, Ultrasonic Processor, 60% amplitude, 750 watt) of ML-Nb2CT and ML-Nb4C3T MXenes (100 mg) in 5 mL of degassed DI water at 20 °C, under a flow of Ar gas for 1 h, followed by freeze-drying.
Characterization
The morphology of prepared DL-Nb2CT and DL-Nb4C3T MXenes were characterized by scanning electron microscopy (SEM), using a FEI Quanta 650 FEG. The transmission electronic microscopy (TEM) was performed by using FEI Talos F200×. The ethanol dispersions of DL-Nb2CT and DL-Nb4C3T were mounted on a lacey Formvar carbon-coated Cu grid for TEM analysis. Bruker D8 Advance X-ray diffractometer with Cu-Kα radiation (λ = 1.54056 Å) was used to record X-ray diffractograms.
Fabrication of DL-Nb2CT and DL-Nb4C3T modified electrodes and electrochemical analysis
Prior to experiments, GCE was polished with alumina powder followed by sonication in a copious amount of ethanol and distilled water. 0.2 mg of Nb2CT/Nb4C3T was dissolved in 1 mL of distilled water and homogeneous suspension was made by sonication for 1 min. Then, 6 μL of this suspension was deposited onto GCE and dried at room temperature for overnight under inert atmosphere. CHI760E electrochemical work station (CHI, Texas, USA) was used to conduct all electrochemical measurements with a three electrode system. The three electrode system consist of a modified GCE as the working electrode, Pt wire as the counter electrode, and Ag/AgCl in saturated KCl as the reference electrode. Cyclic voltammetry (CV) were performed at a scan rate of 100 mV s−1 in the 0.1 M PB solution (pH 7) and in the solution of 0.1 M KCl with 10 mM [Fe(CN)6]3−/4−. Electrochemical impedance spectroscopy (EIS) measurements were performed at a potential of 10 mV in the 100 kHz to 0.1 Hz frequency range.
Stripping voltammetry analysis
Square wave anodic stripping voltammetry (SWASV) measurements were used to detect Pb2+ in acetate buffer solution (0.1 M, pH 5.0) containing different concentration Pb2+. The pre concentration step was performed at −1.2 V for 150 s while stirring the electrolyte solution. SWASV voltammograms were recorded after an equilibration period of 15 s, in the potential range from −0.8 V to 0 V with square wave potential scan having 4 mV increment potential, 25 mV amplitude and 50 Hz frequency. After each anodic stripping measurement, a desorption step was performed at a potential of 0.8 V for 100 s under stirring to remove the residual heavy metal ions on the electrode surface. For interference measurements, the pre concentration step was carried out at the potential of −1.2 V for 150 s while string the electrolyte solution containing Cd2+ and Cu2+ (5 times concentration than Pb2+) followed by recording SWASV voltammograms in the potential range from −1.2 V to 0 V. Error bars shows the standard deviation for three repetitive measurements in each experiment.
Results and discussion
Material characterization
DL-Nb2CT and DL-Nb4C3T MXenes nanosheets were prepared by acid etching of Al layer using HF aqueous solution from their corresponding MAX phases as described in the Experimental section, followed by sonication and freeze drying. SEM images in (Fig. 1(a and c)) describe the typical accordion-like structure in both multi-layered (ML)-Nb2CT and ML-Nb4C3T (Fig. 1(a and c)). After probe sonication, DL-Nb2CT and DL-Nb4C3T showed similar wrinkled sheet-like structure (Fig. 1(b and d)). Energy-dispersive spectroscopy (EDS) confirmed the presence of fluorine, oxygen, carbon and niobium elements in both MXenes (Fig. S1†). The TEM images revealed electron transparent single or few sheets with an average of 200–400 nm sheet size (Fig. 1(c and f)). In addition, the high resolution TEM (HR-TEM) images of DL-Nb2CT and DL-Nb4C3T shown in the inset shows the d-spacing ∼11.5 Å and ∼15 Å, respectively.[36] The XRD patterns of ML-Nb2CT, DL-Nb2CT, ML-Nb4C3T and DL-Nb4C3T are given in Fig. S2.† After delamination the intensity of (002) peaks were increased while intensity of other peaks decreased. The strong characteristic peak (002) in both DL-Nb2CT (at 2theta of 7.87°) and DL-Nb4C3T (at 2theta of 5.94°) confirmed the successful delamination and preparation of DL-MXenes.[23,35] DL-Nb2CT has a smaller c lattice parameter (c-LP) of 22.44 Å as compared to 29.70 Å for DL-Nb4C3T, as calculated from (002) peak position. The corresponding interlayer distance for DL-Nb2CT was 11.22 Å and 14.85 Å for DL-Nb4C3T, which is in a good agreement with the TEM results. The interlayer spacing in DL-Nb4C3T were higher than that of DL-Nb2CT, which could explain the interplanar distance increases with carbide blocks (n) in each MXene layer of MXT. A 14.85 Å spacing of DL-Nb4C3T is larger than most studied MXenes.[41] As far as the electrochemical performance is concerned, larger interlayer space allows faster adsorption and intercalation of ions, and it enhances ion diffusion and charge transport of the electrolyte.[42]
Fig. 1
SEM image of (a) ML-Nb2CT (b) DL-Nb2CT (d) ML-Nb4C3T and (e) DL-Nb4C3T. TEM image of (c) DL-Nb2CT and (f) DL-Nb4C3T. HR-TEM image of DL-Nb2CT and DL-Nb4C3T are shown in the inset of (c) and (f) respectively.
Electrochemical characterization of Nb2CT and Nb4C3T
The fabrication of Nb4C3T modified GCE and the development of Nb4C3T modified sensor for Pb2+ detection is given in Scheme 1. CV and EIS analysis were used to investigate the electrochemical behaviour of Nb2CT and Nb4C3T modified electrodes in an aqueous solution containing ferrocyanide/ferricyanide redox couple solution. As observed in Fig. 2(a), well-defined redox peaks were observed for all the electrodes and these peaks can be attributed to the reversible redox behaviour of [Fe(CN)6]3−/4−. The ΔEp values for Nb2CT/GCE and Nb4C3T/GCE were 197 mV and 141 mV, respectively and the lowest ΔEp value of Nb4C3T/GCE indicating highest electron transfer kinetics than Nb2CT/GCE. In addition, the ΔIp values for Nb2CT/GCE and Nb4C3T/GCE were 114.51 mV and 110.10 mV respectively. The higher value of ΔIp again confirmed the highest electron transfer kinetics of Nb4C3T/GCE than Nb2CT/GCE. The electrochemical active surface area was calculated by using the Randles–Sevcik equation and it has a value of 0.574 × 10−3 cm2 and 0.621 × 10−3 cm2 for Nb2CT and Nb4C3T respectively (see ESI†).[43] The Nyquist plot for Nb2CT/GCE and Nb4C3T/GCE is given in Fig. 2(b). The charge transfer resistance (Rct) parameter was obtained after fitting the Nyquist plot and was used to evaluate the electron-transfer kinetics of the redox couple at the electrode interface.[44] The Rct values obtained for Nb2CT/GCE and Nb4C3T/GCE were (2142 ± 24) Ω and (1732 ± 19) Ω respectively by fitting with R(Q[RW]) Randles equivalent circuit. The resistivity is lowest for Nb4C3T/GCE and hence Nb4C3T is having the highest conductivity than Nb2CT which can be justified by the higher ‘n’ value of Nb4C3T (n = 3) than Nb2CT (n = 1).[45] From the CV and EIS analysis, it was found that Nb4C3T having highest electrochemical activity.
Scheme 1
The electrode fabrication and development of Nb4C3T modified sensor for Pb2+ detection.
Fig. 2
(a) CVs of bare GCE, Nb2CT/GCE and Nb4C3T/GCE. (b) Nyquist plots of Nb2CT/GCE and Nb4C3T/GCE. Frequency range: 0.1 Hz to 10 kHz. The experiments were performed in the solution of 0.1 M KCl with 10 mM [Fe(CN)6]3−/4−.
Stripping behaviour of Pb2+ and optimization of experimental parameters
The SWASV response of the bare GCE, Nb2CT/GCE and Nb4C3T/GCE were analyzed for the detection of Pb2+ ions using acetate buffer solution containing 0.5 μM Pb2+. Compared with the bare GCE, well defined stripping peaks at around −0.58 V were observed for the Nb2CT/GCE and Nb4C3T/GCE and the peak current is highest for Nb4C3T/GCE than Nb2CT/GCE (Fig. 3(a)). The highest response for Nb4C3T can be attributed to large interlayer spacing, high c lattice parameter value than Nb2CT which is evident from TEM and XRD measurements. In addition, it was established that the resistivity of Nb4C3T is lower than Nb2CT[45] which corresponds to the higher conductivity of Nb4C3T as evident from electrochemical analysis (Fig. 2). Hence, Nb4C3T has been selected as the sensing platform for the sensitive detection of Pb2+.
Fig. 3
(a) SWASV responses for bare GCE, Nb2CT/GCE and Nb4C3T/GCE in presence of 0.5 μM of Pb2+ in 0.5 M acetate buffer at pH 5, deposition potential of −1.2 V and deposition time of 150 s. Optimization of experimental parameters. (b) pH, (c) deposition potential, and (d) deposition time towards the stripping current of Nb4C3T/GCE.
The optimum conditions for highly sensitive Pb2+ detection were evaluated by changing the critical parameters such as pH, deposition time and potential. The impact of pH on the stripping current was studied from 3.0 to 6.0 (Fig. 3(b)). The peak current of Pb2+ was increased with increasing the pH from 3.0 to 5.0 and then decreased at pH = 6. The presence of [Nb–O]–H+ groups favours the ion exchange behaviour of Nb4C3T and this behaviour increases with the pH which results in the strengthening of stripping current.[32] The decrease in peak currents at pH 6 could be attributed to the hydrolysis of cations results in the formation of more Pb(OH)2, which inhibits the further accumulation of Pb2+. Considering the maximum observed stripping peak current, pH 5 was selected as optimal for subsequent experiments.Deposition potential and time are also critical factors for stripping analysis to detect heavy metal ions. The deposition potential was varied from −1.4 to −0.8 V and the resulting stripping currents increases with negative potential until −1.2 V (Fig. 3(c)). A reduction in the current response was observed at deposition potential lower than −1.2 V. This might be due to occurrence of more hydrogen evolution in the acetate buffer. Hence, the deposition potential of −1.2 V was selected as optimal for further experiments. The deposition time was varied from 50 to 250 s and the stripping peak currents response was evaluated (Fig. 3(d)). The stripping peak current have increased linearly with the deposition time increase. A deposition time of 150 s was selected for subsequent experiments considering the concession between short measurement time, high sensitivity and good reproducibility favoured for practical applications.
Quantitative detection of Pb2+
Under the optimal conditions, the quantitative detection of Pb2+ was performed by SWASV on Nb4C3T/GCE. Fig. 4(a) shows the SWASV responses at different concentrations from 0 to 0.5 μM of Pb2+. The stripping peak currents increases with increasing the Pb2+ concentration and a good linear relationship was observed in the concentration range from 0.025 μM to 0.5 μM. There was no response for the developed sensor when the Pb2+ concentration was less than 0.025 μM and this concentration can be regarded as limit of quantification of the sensor. The corresponding calibration plot is given in Fig. 4(b), by plotting the peak current vs. Pb2+ concentration. The calibration plot equation was represented as i (μA) = 58.49[Pb2+] + 1.13, with 0.99688 as correlation coefficient (R2). The limit of detection (LOD) was calculated as 12 nM (S/N = 3), which is much lower (or comparable) than the similar kind of sensors for Pb2+ detection (refer Table 1). In a similar work with alkaline intercalated Ti3C2T MXene as platform for electrochemical detection of heavy metals, the stripping analysis showed a detection limit of 32 nM with linear range of 0.10–0.55 μM and this response is significantly higher than bare Ti3C2T. The analytical performance of Nb4C3T modified GCE is higher compared to bare Ti3C2T as well as alkaline intercalated Ti3C2T. The analytical performance of Nb4C3T modified GCE was compared with other similar reported electrodes (summarized in Table 1) and it showed that the Nb4C3T modified GCE exhibited a wider range, promising detection limit and enhanced sensitivity. The large interlayer spacing and high c lattice parameter of Nb4C3T (in comparison with Nb2CT) have allowed for the adsorption of larger amount of Pb2+ between the sheets as well as the higher conductivity of Nb4C3T have improved the electrochemical response on the electrode surface. This strategy can be easily implemented into screen printed electrodes for practical and portable applications considering the versatile sensor fabrication by drop-casting Nb4C3T on the electrode followed by drying.[46]
Fig. 4
(a) SWASV response of the Nb4C3T/GCE for in presence of Pb2+ from 0 to 0.5 μM. (b) The calibration plot of peak current vs. Pb2+ concentrations.
The analytical performance of different 2D materials used for Pb2+ detection
Electrode
Detection technique
Detection limit
Linear range
Ref.
l-Cys/AuNPs/NG/GCE
SWV
56 nM
1–80 μM
1
Bismuth modified exfoliated graphite
SWASV
53 nM
1.0–250 μM
9
MWCNT/P1,5-DAN/Pt
SWASV
2.1 μM
4 to 150 μM
16
MWCNT/5-Br-PADAP/GCE
SWASV
100 nM
0.9 to 114.6 μM
17
G/PANI/PS nanoporous fiber/SPCE
SWASV
3.30 μM
10-500 μM
18
l-Cys-rGO/GCE
DPASV
215 nM
0.4 to 1.2 μM
19
Nafion/G/PANI nanocomposite/SPE
SWASV
100 nM
1–300 μM
20
Alk-Ti3C2/GCE
SWASV
32 nM
0.10–0.55 μM
32
Nb4C3Tx/GCE
SWASV
12 nM
0.025–0.5 μM
This work
Selectivity, stability and repeatability
The selectivity of the Nb4C3T/GCE was analyzed in the presence of Cu2+ and Cd2+ as inferring agents in 5 fold excess along with Pb2+ ion. The SWASV was performed under the optimum conditions. It is found that no or negligible change in the peak current of Pb2+ in presence of interfering ions. The peak for Cu2+ at around −0.1 V,[32] is present in the SWASV curve as shown in Fig. 5(a). The peak for Cd2+ at around −0.8 V,[32] is not clearly visible; however, the current response is higher in the particular range where the peak for Cd2+ normally visible. Fig. 5(b) shows the current response for the individual metal ions (Pb2+, Cd2+, Cu2+) and their mixture at −0.58 V. The peak current was almost the same for Pb2+ alone and in the mixture with other interfering ions. These is no current response at particular potential of −0.58 V for the electrolyte solution containing Cd2+ or Cu2+. These results confirmed the insignificant impact of interfering metal ions and hence the selectivity of the sensor at around −0.58 V.
Fig. 5
(a) SWASV response of the Nb4C3T/GCE for Pb2+ (0.1 μM) in presence of Cd2+ (0.5 μM) and Cu2+ (0.5 μM). (b) Selectivity plot-SWASV response of the Nb4C3T/GCE at −0.6 V for different heavy metals. (c) The stability of Nb4C3T/GCE – SWASV responses for 5 repetitive cyclic measurements with 0.2 μM Pb2+. (d) The repeatability of Nb4C3T/GCE – SWASV responses for 5 different electrodes with 0.2 μM Pb2+.
The stability of the Nb4C3T/GCE was investigated after 5 repetitive measurements using the same electrode and electrolyte containing 0.2 μM Pb2+. After every measurement, a desorption step at a potential of 0.8 V was performed before the next electrodeposition steps. It is found that the SWASV response was highly reproducible with RSD value of 2.34 (Fig. 5(c)). In addition, the stripping current of Nb4C3T/GCE for Pb2+ was measured after keeping the electrode at 4 °C for one week and the stripping current obtained was 94.3% of the initial current with RSD of 3.15. These results confirmed the stability of the Nb4C3T/GCE electrode towards the detection of Pb2+. The reproducibility analysis of the sensor was carried out by using five identical Nb4C3T/GCE electrodes for the detection of Pb2+ using similar procedures. The SWASV responses for five different electrodes with 0.2 μM Pb2+ showing good repeatability between different electrodes with RSD value of 3.67 (Fig. 5(d)).
Practical applications
To evaluate the practical applications of the developed Nb4C3T/GCE sensor, the response of the sensor has been measured after spiking the Pb2+ in bottled and tap water samples. The SWASV response of the sensor has been measured and the results are given in Table 2. The sensor exhibited a promising recovery between 95% and 102% with a relative standard deviation of 1.8–3.0%. From these results, it was confirmed that the developed sensor can be used for the detection of Pb2+ from samples.
Recovery of Pb2+ in drinking water and tap water using the Nb4C3T/GCE sensor
Sample
Pb2+ added (μM)
Pb2+ detected (%)
RSD (%)
Drinking water (bottled)
0.05
95.8
2.35
0.1
99.5
1.81
0.2
96.5
2.57
Tap water
0.05
102.3
2.95
0.1
97.5
3.02
0.2
95.5
2.13
Conclusions
The electrochemical behaviour of Nb2CT and Nb4C3T was investigated to explore its potential in electrochemical applications. The Nb4C3T has demonstrated promising electrochemical performance and its electrochemical response is higher than Nb2CT. The electrochemical detection capability of Nb4C3T towards Pb2+ ions has been investigated by stripping analysis at optimized conditions. Evident by the high sensitivity and good reproducibility, the large interlayer spacing of Nb4C3T can accommodate Pb2+ ions without destroying the layered structure of the electrode. The results showed that Nb4C3T can be used as an immobilization platform for sensitive detection of Pb2+ with wide linear range and detection limit of 12 nM. This work validates the potential application of Nb4C3T for the first time towards electrochemical sensing applications.
Authors: Nipapan Ruecha; Nadnudda Rodthongkum; David M Cate; John Volckens; Orawon Chailapakul; Charles S Henry Journal: Anal Chim Acta Date: 2015-02-27 Impact factor: 6.558
Authors: M Ghidiu; M Naguib; C Shi; O Mashtalir; L M Pan; B Zhang; J Yang; Y Gogotsi; S J L Billinge; M W Barsoum Journal: Chem Commun (Camb) Date: 2014-08-28 Impact factor: 6.222