Literature DB >> 35515486

Use of functional near-infrared spectroscopy to evaluate cognitive change when using healthcare simulation tools.

Natasha Taylor1, Martyn Wyres1, Martin Bollard1, Rosie Kneafsey1.   

Abstract

Background: The use of brain imaging techniques in healthcare simulation is relatively rare. However, the use of mobile, wireless technique, such as functional near-infrared spectroscopy (fNIRS), is becoming a useful tool for assessing the unique demands of simulation learning. For this study, this imaging technique was used to evaluate cognitive load during simulation learning events.
Methods: This study took place in relation to six simulation activities, paired for similarity, and evaluated comparative cognitive change between the three task pairs. The three paired tasks were: receiving a (1) face-to-face and (2) video patient handover; observing a simulated scene in (1) two dimensions and (2) 360° field of vision; and on a simulated patient (1) taking a pulse and (2) taking a pulse and respiratory rate simultaneously. The total number of participants was n=12.
Results: In this study, fNIRS was sensitive to variations in task difficulty in common simulation tools and scenarios, showing an increase in oxygenated haemoglobin concentration and a decrease in deoxygenated haemoglobin concentration, as tasks increased in cognitive load.
Conclusion: Overall, findings confirmed the usefulness of neurohaemoglobin concentration markers as an evaluation tool of cognitive change in healthcare simulation. Study findings suggested that cognitive load increases in more complex cognitive tasks in simulation learning events. Task performance that increased in complexity therefore affected cognitive markers, with increase in mental effort required. © Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  cognitive load; fNIRS; simulation

Year:  2020        PMID: 35515486      PMCID: PMC8936993          DOI: 10.1136/bmjstel-2019-000517

Source DB:  PubMed          Journal:  BMJ Simul Technol Enhanc Learn        ISSN: 2056-6697


  22 in total

Review 1.  Shedding light on the adult brain: a review of the clinical applications of near-infrared spectroscopy.

Authors:  Martin Smith
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2011-11-28       Impact factor: 4.226

2.  Cognitive Load Theory for the Design of Medical Simulations.

Authors:  Kristin L Fraser; Paul Ayres; John Sweller
Journal:  Simul Healthc       Date:  2015-10       Impact factor: 1.929

Review 3.  Functional near infrared spectroscopy (fNIRS): an emerging neuroimaging technology with important applications for the study of brain disorders.

Authors:  Farzin Irani; Steven M Platek; Scott Bunce; Anthony C Ruocco; Douglas Chute
Journal:  Clin Neuropsychol       Date:  2007-01       Impact factor: 3.535

4.  Multiple resources and mental workload.

Authors:  Christopher D Wickens
Journal:  Hum Factors       Date:  2008-06       Impact factor: 2.888

5.  Anticipation of a mentally effortful task recruits Dorsolateral Prefrontal Cortex: An fNIRS validation study.

Authors:  Eliana Vassena; Robin Gerrits; Jelle Demanet; Tom Verguts; Roma Siugzdaite
Journal:  Neuropsychologia       Date:  2018-04-26       Impact factor: 3.139

Review 6.  Images of psychopathology.

Authors:  C Frith; R J Dolan
Journal:  Curr Opin Neurobiol       Date:  1998-04       Impact factor: 6.627

7.  Optical brain monitoring for operator training and mental workload assessment.

Authors:  Hasan Ayaz; Patricia A Shewokis; Scott Bunce; Kurtulus Izzetoglu; Ben Willems; Banu Onaral
Journal:  Neuroimage       Date:  2011-06-17       Impact factor: 6.556

Review 8.  Functions of the frontal lobes: relation to executive functions.

Authors:  Donald T Stuss
Journal:  J Int Neuropsychol Soc       Date:  2011-05-24       Impact factor: 2.892

Review 9.  Non-invasive optical spectroscopy and imaging of human brain function.

Authors:  A Villringer; B Chance
Journal:  Trends Neurosci       Date:  1997-10       Impact factor: 13.837

10.  Estimation of optical pathlength through tissue from direct time of flight measurement.

Authors:  D T Delpy; M Cope; P van der Zee; S Arridge; S Wray; J Wyatt
Journal:  Phys Med Biol       Date:  1988-12       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.