| Literature DB >> 35507984 |
Sávio José Cardoso Bezerra1,2, Ítallo Emídio Lira Viana1, Idalina Vieira Aoki3, Simone Duarte2, Anderson Takeo Hara2, Taís Scaramucci1.
Abstract
OBJECTIVE: The aim of this study is to test, in vitro, the anti-cariogenic effect of experimental hybrid coatings, with nano clays of halloysite or bentonite, loaded with sodium fluoride or with a combination of sodium fluoride and stannous chloride, respectively.Entities:
Mesh:
Substances:
Year: 2022 PMID: 35507984 PMCID: PMC9064272 DOI: 10.1590/1678-7757-2021-0643
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 3.144
Figure 1Experimental groups and components
Figure 2A flowgram of methodology
Figure 3Image of enamel slabs positioned in cell plates cover
Figure 4Cariogenic cycling
Figure 5Representative TMR images of each treatment. A: surface adjacent to treatment; B: surface under treatment
Mean and standard deviation (SD) of mineral loss (Vol%.μm], for both areas
| Under-Treatment | Adjacent to Treatment | |||
|---|---|---|---|---|
| Mean | SD | Mean | SD | |
| Fluor Protector | Aa 325.56 | 346.0 | Ab 3350.28 | 1811.4 |
| Hybrid + NaF | Ba 2226.44 | 603.9 | Ab 3655.00 | 781.4 |
| Hybrid + NaF Loaed | BCa 2987.78 | 495.8 | Ab 4036.50 | 1039.0 |
| Hybrid + NaF + SnCl2 Loaed | BCa 3225.56 | 923.0 | Ab 4151.00 | 1340.6 |
| Hybrid + NaF + SnCl2 | Ca 3949.00 | 1663.7 | Aa 3238.00 | 1129.9 |
| Hybrid | Ca 3950.20 | 1280.3 | Aa 3772.00 | 1219.0 |
| Control | Ca 4110.00 | 1414.5 | Aa 3586.00 | 1221.7 |
Data analyzed by two-way repeated measured ANOVA. Different uppercase letters show statistical difference in a column by Tukey test. Different lowercase letters show statistical difference in a row by Tukey test
Mean and SD of Lesion Depth (in μm), for both areas
| Under-Treatment | Adjacent to Treatment | |||
|---|---|---|---|---|
| Mean | SD | Mean | SD | |
| Fluor Protector | Aa 15.72 | 18.8 | Bb 120.58 | 42.4 |
| Hybrid + NaF | Ba 110.18 | 14.3 | ABb 151.73 | 27.5 |
| Hybrid + NaF Loaed | Ba 113.74 | 15.1 | Ba 123.62 | 26.5 |
| Hybrid + NaF + SnCl2 Loaded | Ba 127.14 | 42.0 | Aa 146.27 | 38.8 |
| Hybrid + NaF + SnCl2 | Ba 153.32 | 50.5 | Aa 137.09 | 53.8 |
| Hybrid | Ba 129.66 | 30.5 | Aa 185.94 | 83.1 |
| Control | Ba 135.52 | 44.3 | Ba 114.53 | 22.1 |
Data analyzed by two-way repeated measured ANOVA. Different uppercase letters show statistical difference in a column by Tukey test. Different lowercase letters show statistical difference in a row by Tukey test
Figure 6pH measurement of the medium during the cycling
Figure 7Images after staining with the Live/dead staining viability kit. Vital microorganism (green) and dead bacteria (red) are detectable at the enamel surface areas in the under-treatment and adjacent to treatment, for all experimental groups
Figure 8Fluoride release (µg/mL) over the cycling days