| Literature DB >> 35503703 |
Fernando Terziotti1, Emerson Pereira Gregório2, Marcio Augusto Averbeck3, Silvio Henrique Maia Almeida4.
Abstract
PURPOSE: This study examined and compared efficacy, safety, satisfaction, and complications of the retropubic Safyre™ sling and a retropubic hand-made synthetic sling (HMS) in a short-, mid- and long-term follow-up.Entities:
Keywords: Postoperative Complications; Suburethral Slings; Urinary Incontinence
Mesh:
Year: 2022 PMID: 35503703 PMCID: PMC9306358 DOI: 10.1590/S1677-5538.IBJU.2021.0646
Source DB: PubMed Journal: Int Braz J Urol ISSN: 1677-5538 Impact factor: 3.050
Figure 1Flowchart of study selection process
HMS: Handmade Sling
*Deaths occurred at follow-up due to other causes (neoplasm, trauma, diverticular disease); data were used only for preoperative evaluations
#Neurogenic bladder, previous bladder augmentation, pelvic organs prolapse (grade ≥ 2)
Baseline data and urodynamic profile of patients according to the type of sling performed.
| HMS n=125 (56%) | Safyre™ n=96 (44%) | p-value | ||
|---|---|---|---|---|
| 58.94 (±11.62) | 60.33 (±12.26) | 0.391b | ||
| 33 (26.4%) | 26 (27.1%) | 0.909a | ||
| 28.38 (±5.19) | 27.69 (±4.64) | 0.307b | ||
| Hormonal Status | Menopause without HR | 81 (64.8%) | 48 (50.0%) | 0.149d |
| Menopause with HR | 18 (14.4%) | 27 (28.1%) | ||
| Premenopausal | 26 (20.8%) | 21 (21.9%) | ||
| Pads usage | Daily | 50 (40.0%) | 58 (60.4%) | |
| If necessary | 25 (20.0%) | 18 (18.8%) | ||
| None | 50 (40.0%) | 20 (20.8%) | ||
| 10 (9.0 – 11.0) | 10 (9.0 – 12.0) | 0.164c | ||
| Parity, median (IR) | Pregnancies | 3.0 (2.0 – 3.25) | 2.0 (2.0 – 3.0) | 0.156c |
| Normal birth | 2.0 (0 – 3.0) | 2.0 (0 – 3.0) | 0.264c | |
| Cesarean section | 0 (0 – 1.25) | 1.0 (0 – 2.0) | 0.330c | |
| Previous surgeries | Incontinence | 19 (15.2%) | 17 (17.7%) | 0.617a |
| Pelvic Organ Prolapse | 39 (31.2%) | 23 (24.0%) | 0.235a | |
| Hysterectomy | 34 (27.2%) | 26 (27.1%) | 0.985a | |
| Abdominal (others) | 23(18.4%) | 19 (19.8%) | 0.794a | |
| 103.48 (±38.01) | 103.04 (±40.83) | 0.934b | ||
| Leakage type | Stress | 111 (88.8%) | 82 (85.4%) | 0.453a |
| Mixed | 14 (11.2%) | 14 (14.6%) | ||
| Post-voiding residual urine | <30mL | 93 (74.4%) | 82 (85.4%) | 0.665d |
| 30-100mL | 21 (16.8%) | 4 (4.2%) | ||
| >100mL | 11 (8.8%) | 10 (10.4%) | ||
HMS = Handmade Sling; BMI = Body Mass Index; HR = Hormonal Replacement; ICIQ-UI SF = International Consultation on Incontinence Modular Questionnaire for Urinary Incontinence Short Form; VLPP = Valsalva leak-point pressure; SD = standard deviation; IR = interquartile range
a Chi-squared test; b T-Test; c Mann-Whtney U test; d Chi-squared test for trend; e Fisher’s exact test
Complications according to the type of sling performed.
| HMS n=125 (56%) | Safyre™ n=96 (44%) | p-value | ||
|---|---|---|---|---|
| Intraoperative bladder injury | 0 (0.0%) | 4 (4.2%) | ||
| Urinary infection | 14 (11.2%) | 10 (10.4%) | 0.853a | |
| Vaginal bleeding | 28 (22.4%) | 18 (18.8%) | 0.508a | |
| LIC>24h | 3 (2.4%) | 8 (8.3%) | 0.061e | |
| Sling readjustment | None | 118 (94.4%) | 88 (91.7%) | 0.434e |
| Tightening g | 1 (0.8%) | 2 (2.4%) | ||
| Loosening g | 3 (2.4%) | 2 (2.1%) | ||
| Urethrolysis h | 3 (2.4%) | 4 (4.2%) | ||
| Stress Incontinence | 12 (9.6%) | 11 (11.5%) | 0.654a | |
| Urgency Incontinence | 23 (18.4%) | 24 (25.0%) | 0.235a | |
| Mixed Incontinence | 5 (4.0%) | 10 (10.4%) | 0.060a | |
| Pain | 24 (19.2%) | 14 (14.6%) | 0.367a | |
| 16 (12.8%) | 6 (6.2%) | 0.107a | ||
| Time (months), median (IR) | 6.0 (2.0 – 12.0) | 3.0 (2.0 – 4.0) | 0.120c | |
| Treatment | None | 109 (87.2%) | 90 (93.7%) | 0.118e |
| Topical | 12 (9.6%) | 4 (4.2%) | ||
| Surgical | 4 (3.2%) | 2 (2.1%) | ||
| Clavien-Dindo | None | 101 (80.8%) | 83 (86.5%) | 0.282e |
| II | 4 (3.2%) | 2 (2.1%) | ||
| IIIa | 5 (4.0%) | 3 (3.1%) | ||
| IIIb | 15 (12.0%) | 8(8.3%) |
HMS = Handmade Sling; LIC>24h = Long-term indwelling catheter for more than 24 hours.
IR = Interquartile Range
a Chi-squared test; c Mann-Whitney U test; e Fisher’s exact test; g Performed before discharged; h Performed before sixth postoperative month
Telephone evaluation according type of sling performed.
| HMS n=115 (56%) | Safyre™ n=92 (44%) | p-value | |
|---|---|---|---|
| Deaths* | 10 (8.0%) | 4 (4.2%) | 0.246a |
| Loss of follow-up | 58 (31.7%) | 31 (24.4%) | 0.163a |
| Follow-up (months), mean (SD) | 85.05 (±40.93) | 69.90 (±33.90) | 0.004b |
| Postoperative ICIQ-UI SF, median (IR) | 3 (0.0 –12.75) | 3.5 (0.0 – 9.5) | 0.476c |
| ICIQ-UI SF dif (pre – post), median (IR) | 6 (2 – 8) | 6 (4 – 8) | 0.142c |
| De novo urgency | 46 (40.0%) | 39 (42.4%) | 0.728a |
| Urinary Tract Infection | 20 (17.4%) | 17 (18.5%) | 0.839a |
| Vaginal bleeding | 3 (2.6%) | 0 (0.0%) | 0.256e |
| Voiding symptoms | 13 (11.3%) | 4 (4.3%) | 0.070a |
| Pelvic pain | 8 (7.0%) | 5 (5.4%) | 0.654a |
| Dyspareunia | 0 (0.0%) | 3 (3.3%) | 0.086e |
| Satisfaction | 91 (79.1%) | 76 (82.6%) | 0.529a |
| Subjective Cure | 79 (68.7%) | 73 (79.3%) | 0.085a |
HMS = Handmade Sling; ICIQ-UI SF = International Consultation on Incontinence Modular Questionnaire for Urinary Incontinence Short Form; dif = difference.
SD = Standard Deviation; IR = Interquartile Range;
a Chi-squared test; b T-test; c Mann-Whitney U test; e Fisher’s exact test
* Not related to the procedure
Median (IR) of preoperative and postoperative ICIQ-UI SF according to the follow-up quartiles and type of sling performed.
| HMS | |||
|---|---|---|---|
|
| |||
| Follow-up (months) | Preoperative ICIQ-UI SF | Postoperative ICIQ-UI SF | p-value |
| 13 – 42 (n=27) | 9 (8.5 – 12) | 0 (0 – 12) | |
| 43 – 79 (n=21) | 10 (9 – 12) | 9 (0 – 16) | 0.163f |
| 80 – 103 (n=28) | 10 (9 – 10.5) | 3 (0 – 13.5) | |
| 104 – 165 (n=39) | 9 (8 – 12) | 5 (0 – 13) | |
|
| |||
| 10 (9 – 11) | 3 (0 – 13) | ||
|
| |||
| Safyre™ | |||
|
| |||
| 13 – 42 (n=24) | 9.5 (8.25 – 11) | 1.5 (0 – 8) | |
| 43 – 79 (n=31) | 10 (8.5 – 13) | 5 (0 – 13) | |
| 80 – 103 (n=24) | 11 (8.5 – 13.5) | 5 (0 – 8) | |
| 104 – 165 (n=13) | 9.5 (9 – 12.5) | 3 (0 – 11) | |
|
| |||
| 10 (9 – 12) | 3.5 (0 – 9.75) | ||
HMS = Handmade Sling; ICIQ-UI SF = International Consultation on Incontinence Modular Questionnaire for Urinary Incontinence Short Form.
IR = Interquartile Range
f Wilcoxon test
Comparison of difference in ICIQ-UI SF (pre – post), satisfaction, and subjective cure, according to follow-up quartiles, between sling groups.
| Follow-up (months) | HMS | Safyre™ | p-value |
|---|---|---|---|
| 13 – 42 (n=51) | 8 (-2.25 – 9) (n=27) | 7 (1.5 – 10) (n=24) | 0.813c |
| 43 – 79 (n=52) | 3 (-4.25 – 10) (n=21) | 5 (-0.5 – 9) (n=31) | 0.386c |
| 80 – 103 (n=52) | 7 (-2.5 – 9) (n=28) | 6.5 (2 – 10.5) (n=24) | 0.138c |
| 104 – 165 (n=52) | 6 (-3 – 9) (n=39) | 6 (2.5 – 9) (n=13) | 0.336c |
| 13 – 42 (n=51) | 24 (89%) | 22 (91.7%) | 0.890a |
| 43 – 79 (n=52) | 12 (57.2%) | 27 (87.1%) | |
| 80 – 103 (n=52) | 21 (75%) | 18 (75%) | 0.748a |
| 104 – 165 (n=52) | 34 (87.2%) | 9 (69.2%) | 0.290a |
| 13 – 42 (n=51) | 21 (77.8%) | 20 (83.3%) | 0.884a |
| 43 – 79 (n=52) | 14 (66.7%) | 25 (80.6%) | 0.414a |
| 80 – 103 (n=52) | 19 (67.9%) | 20 (83.3%) | 0.335a |
| 104 – 165 (n=52) | 25 (64.1%) | 8 (61.6%) | 0.868a |
HMS = Handmade Sling; ICIQ-UI SF , International Consultation on Incontinence Modular Questionnaire for Urinary Incontinence Short Form. IR = Interquartile Range
a Chi-squared test; c Mann-Whitney U test