Literature DB >> 35501623

Editorial Comment to: Perioperative complications after pacemaker implantation: Higher complication rates with subclavian vein puncture than with cephalic vein cut-down (Hasan et al.).

Yury Malyshev1, Felix Yang2.   

Abstract

Entities:  

Year:  2022        PMID: 35501623     DOI: 10.1007/s10840-022-01221-0

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


× No keyword cloud information.
  14 in total

1.  Subclavian and Axillary Vein Access Versus Cephalic Vein Cutdown for Cardiac Implantable Electronic Device Implantation: A Meta-Analysis.

Authors:  Varunsiri Atti; Mohit K Turagam; Jalaj Garg; Scott Koerber; Aakash Angirekula; Rakesh Gopinathannair; Andrea Natale; Dhanunjaya Lakkireddy
Journal:  JACC Clin Electrophysiol       Date:  2020-03-16

2.  Preferred tools and techniques for implantation of cardiac electronic devices in Europe: results of the European Heart Rhythm Association survey.

Authors:  Maria Grazia Bongiorni; Alessandro Proclemer; Dan Dobreanu; Germanas Marinskis; Laurent Pison; Carina Blomstrom-Lundqvist
Journal:  Europace       Date:  2013-11       Impact factor: 5.214

3.  Fluoroscopy-guided axillary vein access vs cephalic vein access in pacemaker and defibrillator implantation: Randomized clinical trial of efficacy and safety.

Authors:  Javier Jiménez-Díaz; Felipe Higuera-Sobrino; Jesús Piqueras-Flores; Pedro Pérez-Díaz; María Arantzazu González-Marín
Journal:  J Cardiovasc Electrophysiol       Date:  2019-07-23

4.  EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS).

Authors:  Haran Burri; Christoph Starck; Angelo Auricchio; Mauro Biffi; Mafalda Burri; Andre Lahrs Representative D'Avila; Jean-Claude Deharo; Michael Glikson; Carsten Israel; Chu-Pak Aphrs Representative Lau; Christophe Leclercq; Charles J Hrs Representative Love; Jens Cosedis Nielsen; Kevin Vernooy; Nikolaos Review Coordinator Dagres; Serge Review Coordinator Boveda; Christian Butter; Eloi Marijon; Frieder Braunschweig; Georges H Mairesse; Marye Gleva; Pascal Defaye; Francesco Zanon; Nestor Lopez-Cabanillas; Jose M Guerra; Vassilios P Vassilikos; Mario Martins Oliveira
Journal:  Europace       Date:  2021-04-20       Impact factor: 5.214

5.  Comparison of the axillary venous approach and subclavian venous approach for efficacy of permanent pacemaker implantation. 8-Year follow-up results.

Authors:  Ki-Hun Kim; Kyoung-Min Park; Gi-Byoung Nam; Dae-Kyeong Kim; Minkyung Oh; Hyungoh Choi; Taek Jong Hong; Bo-Min Park; Guang-Won Seo; Pil-Sang Song; Dong-Kie Kim; Sang-Hoon Seol; Doo-Il Kim; You-Ho Kim; Kee-Joon Choi
Journal:  Circ J       Date:  2014-03-03       Impact factor: 2.993

6.  2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy.

Authors:  Michael Glikson; Jens Cosedis Nielsen; Mads Brix Kronborg; Yoav Michowitz; Angelo Auricchio; Israel Moshe Barbash; José A Barrabés; Giuseppe Boriani; Frieder Braunschweig; Michele Brignole; Haran Burri; Andrew J S Coats; Jean-Claude Deharo; Victoria Delgado; Gerhard-Paul Diller; Carsten W Israel; Andre Keren; Reinoud E Knops; Dipak Kotecha; Christophe Leclercq; Béla Merkely; Christoph Starck; Ingela Thylén; José Maria Tolosana
Journal:  Eur Heart J       Date:  2021-09-14       Impact factor: 29.983

7.  European Society of Cardiology: Cardiovascular Disease Statistics 2017.

Authors:  Adam Timmis; Nick Townsend; Chris Gale; Rick Grobbee; Nikos Maniadakis; Marcus Flather; Elizabeth Wilkins; Lucy Wright; Rimke Vos; Jeroen Bax; Maxim Blum; Fausto Pinto; Panos Vardas
Journal:  Eur Heart J       Date:  2018-02-14       Impact factor: 29.983

8.  Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

Authors:  Fabien Squara; Julien Tomi; Didier Scarlatti; Guillaume Theodore; Pamela Moceri; Emile Ferrari
Journal:  Europace       Date:  2017-12-01       Impact factor: 5.214

9.  Venous access and long-term pacemaker lead failure: comparing contrast-guided axillary vein puncture with subclavian puncture and cephalic cutdown.

Authors:  Ngai-Yin Chan; Nim-Pong Kwong; Adrian-Piers Cheong
Journal:  Europace       Date:  2017-07-01       Impact factor: 5.214

10.  Perioperative complications after pacemaker implantation: higher complication rates with subclavian vein puncture than with cephalic vein cutdown.

Authors:  Fuad Hasan; Sotirios Nedios; Zana Karosiene; Marvin Scholten; Bernd Lemke; Sabrina Tulka; Stephanie Knippschild; Susanne Macher-Heidrich; Heinz Jürgen Adomeit; Markus Zarse; Harilaos Bogossian
Journal:  J Interv Card Electrophysiol       Date:  2022-02-02       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.