Consumer Devices for Patient-Generated Health Data Using Blood Pressure Monitors for Managing Hypertension: Systematic Review.

Jonathan R Treadwell1, Benjamin Rouse1, James Reston1, Joann Fontanarosa1, Neha Patel2, Nikhil K Mull3.   

Abstract

BACKGROUND: In the era of digital health information technology, there has been a proliferation of devices that collect patient-generated health data (PGHD), including consumer blood pressure (BP) monitors. Despite their widespread use, it remains unclear whether such devices can improve health outcomes.
OBJECTIVE: We performed a systematic review of the literature on consumer BP monitors that collect PGHD for managing hypertension to summarize their clinical impact on health and surrogate outcomes. We focused particularly on studies designed to measure the specific effect of using a BP monitor independent of cointerventions. We have also summarized the process and consumer experience outcomes.
METHODS: An information specialist searched PubMed, MEDLINE, and Embase for controlled studies on consumer BP monitors published up to May 12, 2020. We assessed the risk of bias using an adapted 9-item appraisal tool and performed a narrative synthesis of the results.
RESULTS: We identified 41 different types of BP monitors used in 49 studies included for review. Device engineers judged that 38 (92%) of those devices were similar to the currently available consumer BP monitors. The median sample size was 222 (IQR 101-416) participants, and the median length of follow-up was 6 (IQR 3-12) months. Of the included studies, 18 (36%) were designed to isolate the clinical effects of BP monitors; 6 of the 18 (33%) studies evaluated health outcomes (eg, mortality, hospitalizations, and quality of life), and data on those outcomes were unclear. The lack of clarity was due to low event rates, short follow-up duration, and risk of bias. All 18 studies that isolated the effect of BP monitors measured both systolic and diastolic BP and generally demonstrated a decrease of 2 to 4 mm Hg in systolic BP and 1 to 3 mm Hg in diastolic BP compared with non-BP monitor groups. Adherence to using consumer BP monitors ranged from 38% to 89%, and ease of use and satisfaction ratings were generally high. Adverse events were infrequent, but there were a few technical problems with devices (eg, incorrect device alerts).
CONCLUSIONS: Overall, BP monitors offer small benefits in terms of BP reduction; however, the health impact of these devices continues to remain unclear. Future studies are needed to examine the effectiveness of BP monitors that transmit data to health care providers. Additional data from implementation studies may help determine which components are critical for sustained BP improvement, which in turn may improve prescription decisions by clinicians and coverage decisions by policy makers. ©Jonathan R Treadwell, Benjamin Rouse, James Reston, Joann Fontanarosa, Neha Patel, Nikhil K Mull. Originally published in JMIR mHealth and uHealth (https://mhealth.jmir.org), 02.05.2022.

Entities:  

Keywords:  blood pressure monitors; cardiovascular diseases; consumer devices; digital health; health information; hypertension; mobile phone; patient-generated health data; wearable devices

Mesh:

Year:  2022        PMID: 35499862      PMCID: PMC9112087          DOI: 10.2196/33261

Source DB:  PubMed          Journal:  JMIR Mhealth Uhealth        ISSN: 2291-5222            Impact factor:   4.947


Introduction

In 2018, nearly half a million deaths in the United States included hypertension as a primary or contributing cause [1]. Current data support the use of out-of-office blood pressure (BP) monitoring for hypertension management because it provides clinical information beyond in-office BP monitoring and enhances titration of the medication dose [2-4]. This evidence has led to the proliferation of consumer patient-generated health data (PGHD) devices for hypertension management. The Office of the National Coordinator for Health Information Technology defines PGHD as “health-related data created, recorded, or gathered by or from patients (or family members or other caregivers) to help address a health concern” [5]. These health-related data are captured by the patient, who may also need to share this information with a health care provider or others (if data transmission is not automatic). The adoption curve of consumer PGHD devices for hypertension management is maturing due to the rising numbers of wearables and BP monitors on the market. The global market size of automated home BP monitors is expected to gain market growth between 2020 and 2025, with a compound annual growth rate of 2.3%, forecasting US $1068.3 million by 2025, from US $975.6 million in 2019 [6]. Consumer PGHD devices can improve the health outcomes of patients and play an important role in managing hypertension. This review summarizes findings on hypertension from a larger report that addressed PGHD for 11 chronic conditions. The full report can be downloaded from the website of the Effective Healthcare Program at the Agency for Healthcare Research and Quality (AHRQ) [7]. In this paper, we summarize the clinical effectiveness of consumer BP monitors in collecting PGHD on health and surrogate outcomes. We also summarize the process outcomes (eg, medication titration) and consumer experience outcomes (eg, device adherence, ease of use, and technical problems).

Methods

Search Strategy

A professional information specialist searched MEDLINE and Embase, in-process MEDLINE and PubMed unique content, and the Cochrane Database of Systematic Reviews for systematic reviews or controlled trials published from inception until May 12, 2020. We also searched ClinicalTrials.gov for active studies until June 19, 2020. The review protocol is posted on the PROSPERO website [7].

Selection Criteria

Textbox 1 shows study eligibility criteria for studies evaluating the effects of BP monitors on hypertension. Device engineers examined the devices from the screened studies (manufacturer and model names) and determined whether each device was available for direct purchase by consumers. Studies that included nonconsumer devices (eg, devices requiring a prescription) were excluded. The technology had to collect and store consumer data without requiring manual input and potentially could be sent to a health care professional, although data transmission was not required for study inclusion. We included both US-marketed and non–US-marketed technologies that met the criteria. However, any technology subject to Food and Drug Administration (FDA) clearance must have received FDA clearance to be included. We carefully examined the interventions provided to each treatment group and determined whether the study design isolated the effect of the BP monitor. This occurred when the intervention group received the BP monitor whereas other comparison groups did not, and any additional treatments were the same between groups. In cases where clinicians made changes to treatment plans (eg, medication or dose adjustments) based on feedback from the BP monitor, we considered it as part of the BP monitor’s effect because such adjustments were only possible due to the device. The comparison groups commonly received usual care, which would not preclude the clinician’s decisions to modify hypertension treatment plans based on BP measurements in other contexts and settings. Using DistillerSR (Evidence Partners), 3 reviewers (JRT, BR, and JR) screened the titles, and all 6 screened abstracts and full-text articles. For titles, only 1 reviewer assessed the general relevance to the topic. For abstract screening, 2 reviewers were necessary to exclude an article from further consideration; however, only 1 reviewer was necessary to order the full text. Regarding full texts, 2 reviewers assessed the study against the inclusion criteria, and disagreements were resolved by a (senior-level) third reviewer (JRT or JR). Full-text screening also involved determining which articles were associated with other included articles of the same trial. Category and criteria Populations Include individuals who have (or may potentially develop) hypertension Exclude individuals with other conditions and pregnant and postpartum women Interventions Include consumer blood pressure (BP) monitors for the prevention or treatment of hypertension. The monitor must collect and store the patient data without manual input, which could be used by the patient or sent to a health care professional (data transmission was not required but could be via the same or a different technology) Comparators Include non–patient-generated health data (PGHD) interventions, other PGHD interventions, or no intervention Exclude comparators that used the same PGHD intervention Outcomes Include health outcomes: direct measures of health (eg, mortality, emergency room visits, hospitalizations, disease progression, and quality of life) Include blood pressure: systolic or diastolic BP change and change in BP control Include potential harms: serious adverse events (eg, hospitalization or delay in care) and other potential harms such as underuse or overuse of medications secondary to inaccurate BP data Include process outcomes (if 1 of the first 3 outcome categories were reported): medication changes Include consumer outcomes (if 1 of the first 3 outcome categories were reported): BP measurement adherence, interoperability, functions, acceptability/usability, sustainability, feasibility, fidelity, and integration into electronic health records Include costs (if 1 of the first 3 outcome categories were reported): total cost and cost-effectiveness Exclude surrogates such as prescription filling behavior, biomarkers that do not define the condition, adherence, disease knowledge, beliefs, opinions, dietary behavior, activity level, and steps per day Timing/setting Include no limitations on timing. The setting must be at home or otherwise outside of a hospital or health care center. Study designs Include any study design with a separate comparison group of patients who received a different intervention strategy or single-arm registry studies. Systematic reviews were only used to screen their included studies to ensure none were missed by the database searches. Exclude reviews, case reports, editorials, comments, letters, meeting abstracts, and studies with <10 patients per arm at follow-up. Language Include studies published in English.

Data Extraction

For each included trial, 1 reviewer (BR or NM) extracted the general trial information, patient characteristics (eg, baseline BP), treatment details (including specific PGHD devices), risk-of-bias items, and outcome data. We examined data on the following reported health outcomes: mortality, emergency room visits, hospitalization, quality of life (QoL), and adverse events (AEs). Surrogate outcomes for hypertension consisted of systolic BP (SBP) and diastolic BP (DBP). Process outcomes included medication changes, dose adjustments, physician consultations, and office visits. We also extracted data on consumer experience, including device adherence, the number of BP readings taken or transmitted, device alerts, ease of use, patient satisfaction, and technical problems.

Risk-of-Bias Assessment

We assessed the overall risk of bias based on 9 items, including randomization, allocation concealment, baseline similarity between groups, and masking of outcome assessors. The items were adapted from the AHRQ report titled “Mobile Applications for Self-Management of Diabetes” [8]. In addition, we included an item about whether the device’s effects could be isolated (ie, consumer BP monitor alone vs usual care). After considering all 9 items, we categorized each trial as at low, moderate, or high risk of bias.

Device Similarity

Given that the included studies were published as early as 1997, for each BP monitor used within the included studies, device engineers assessed the similarity to devices currently on the market from that manufacturer. They used the following scale: (1) this model is similar to a device available from this manufacturer; (2) this model is somewhat different than any device available from this manufacturer; (3) this model is very different from any device available from this manufacturer; and (4) we could not reliably determine the similarity of this model with the ones currently available from this manufacturer.

Results Classification

For isolated effects on health outcomes, we narratively synthesized the summary effect into one of four categories: (1) likely no effect, (2) unclear, (3) possible positive effect, or (4) likely positive effect. If the results consistently demonstrated the lack of an effect (via narrow CIs around a null effect), we coded it as likely no effect. If the results were inconsistent in the direction of effect or study authors could not reach a conclusion, the findings were coded as unclear for that outcome. If ≥1 outcomes had minor inconsistency in findings, but at least 1 study with moderate or low risk of bias showed a positive effect, the findings were coded as possible positive effect. If the results had a consistent positive effect, we coded it as likely positive effect. When we categorized health outcome data as unclear, we then examined surrogate outcomes, which for hypertension were SBP and DBP. To help interpret the SBP/DBP outcomes, we used a minimally important difference of 2 mm Hg [9,10]. For studies of multicomponent interventions, we did not attempt to classify the data in the manner described earlier because the effect of BP monitoring in those studies could not be determined.

Results

Literature Search

For the full report (ie, 11 clinical conditions), our searches identified 8667 potentially relevant articles, of which we excluded 5755 (66.40%) at the title level (not relevant) and 2196 (25.33%) at the abstract level (Figure 1). We dual-screened the full texts of the remaining 716 articles (8.26%). The review team included 126 (17.6%) of these studies, but upon further review of the devices by device engineers, 12 studies (1.7%) had used only nonconsumer devices and were therefore excluded from the full report (none of the 12 addressed hypertension). A total of 114 unique studies were described in 166 articles. For the subset of screened studies enrolling patients with hypertension, we included 51 studies reported in 80 articles. This review focuses on 49 (96%; 79 articles) of those 51 studies that used BP monitors to generate PGHD for managing hypertension; 2 studies did not use BP monitors to manage hypertension, 1 evaluated a pedometer [11], and the other compared 2 mobile apps [12]. Of the 49 studies, 18 (36.7%) used designs that isolated the effect of BP monitors (eg, BP monitor alone vs usual care or BP monitor+scale vs scale alone), whereas the other 31 (63.3%) used multicomponent designs that did not permit conclusions about the impact on outcomes specific to BP monitors (eg, BP monitor+scale vs usual care).
Figure 1

Study flow diagram. BP: blood pressure; DBP: diastolic blood pressure; PGHD: patient-generated health data; SBP: systolic blood pressure.

Study flow diagram. BP: blood pressure; DBP: diastolic blood pressure; PGHD: patient-generated health data; SBP: systolic blood pressure.

Study Characteristics

Key characteristics of the studies using BP monitors for hypertension are shown in Table 1 (18 isolated-effect studies) and Multimedia Appendix 1 (Table S1; 31 multicomponent studies). Of the 49 studies, 47 (96%) were randomized trials, and 2 (4%) were nonrandomized; 21 (43%) studies were conducted in the United States, and other notable countries included the United Kingdom (n=6 studies, 12%), Canada (n=3 studies, 6%), Denmark (n=2 studies. 4%), Finland (n=2 studies, 4%), and South Korea (n=2 studies, 4%). The median number of patients per study at baseline was 222 (IQR 80-433). Patient enrollment dates were reported in 29 (59%) studies and ranged from May 1999 to June 2017. The median length of follow-up was 6 months (IQR 4-12).
Table 1

General characteristics of studies isolating the effect of blood pressure monitors.

StudyDesignCountryN at baselineStudy durationStudy groups (BPa monitor manufacturer and model)Outcomes
Aekplakorn et al (2016) [13]RCTbThailand22412 months

PGHDc (Omron HEM 7117)

Usual care

Surrogate (SBPd, DBPe, or BP control)

Process

Consumer experience

Bosworth et al (2009) [14]RCTUnited States6362 years

PGHD (Omron 773AC or 637)

Behavioral intervention

Combination (PGHD+behavioral)

Usual care

Health (hospitalizations)

Surrogate (SBP, DBP, or BP control)

Process

Adverse events

Consumer experience

Bosworth et al (2011) [15-17]RCTUnited States63624 months

PGHD (Omron 773AC or 637)

Behavioral intervention

Combination (PGHD+behavioral)

Usual care

Surrogate (SBP or DBP)

Broege 2001 [18]RCTUnited States403 months

PGHD (Omron HEM-702)

Usual care

Health (QoLf)

Surrogate (SBP or DBP)

Consumer experience

Fuchs et al (2012) [19]RCTBrazil12160 days

PGHD (Omron HEM-705 CP)

Usual care

Surrogate (SBP or DBP)

Consumer experience

Green et al (2008) [20,21]RCTUnited States7781 year

PGHD (Omron HEM-705 CP)

Combination (PGHD+pharmacist care)

Usual care

Health (QoL)

Surrogate (SBP, DBP, or BP control)

Adverse events

Hebert et al (2012) [22]RCTUnited States41618 months

PGHD (Omron HEM-712C)

Combination (PGHD+nurse management)

Usual care

Health (mortality)

Surrogate (SBP, DBP, or BP control)

Process

Hoffmann-Petersen et al (2017) [23]RCTDenmark3563 months

PGHD (A&D 767PlusBT or Omron 705IT)

Usual care

Surrogate (SBP, DBP, or BP control)

Process

Hosseininasab et al (2014) [24]RCTIran19424 weeks

PGHD (Samsung SHB-200w)

Usual care

Surrogate (SBP or DBP)

Kaihara et al (2014) [25]RCTJapan572 weeks

PGHD (Omron HEM-7251G)

Conventional BP monitor

Surrogate (SBP or DBP)

Consumer experience

Kauric-Klein et al (2007) [26]RCTUnited States3412 weeks

PGHD (Omron IC)

Usual care

Surrogate (SBP or DBP)

Kim et al (2016) [27,28]RCTUnited States1606 months

PGHD (Withings)

Usual care

Surrogate (SBP, DBP, or BP control)

Consumer experience

Lakshminarayan et al (2018) [29]RCTUnited States5013 weeks

PGHD (upper arm Withings [Nikia] wireless BP monitor)

Conventional BP monitor

Surrogate (SBP)

Consumer experience

Márquez-Contreras et al (2006) [30]RCTSpain2506 months

PGHD (Omron M4 automatic monitor)

Usual care

Surrogate (SBP, DBP, or BP control)

McManus et al (2018) [4,31-33]RCTUnited Kingdom117312 months

PGHD (Omron M10-IT)

Combination (PGHD+telemonitoring)

Usual care

Health (QoL)

Surrogate (SBP or DBP); process

Adverse events

Qi et al (2017) [34]RCTChina10325 years

PGHD (Omron HEM-7121)

Control group

Surrogate (SBP, DBP, or BP control)

Zaleski et al (2019) [35]RCTUnited States244 months

PGHD (BP Omron 705 CPN)

Usual care

Surrogate (SBP or DBP)

Adverse events

Consumer experience

Zha et al (2019) [36]RCTUnited States256 months

PGHD (iHealth BP 7 wireless BP wrist monitor)

Usual care

Health (QoL)

Surrogate (SBP, DBP, or BP control)

Consumer experience

aBP: blood pressure.

bRCT: randomized controlled trial.

cPGHD: patient-generated health data.

dSBP: systolic blood pressure.

eDBP: diastolic blood pressure.

fQoL: quality of life.

Study group comparisons are shown in Table 2 and Multimedia Appendix 1 (Table S1). Of the 49 studies, 42 (86%) had 2 study groups, 4 (8%) studies had 3 groups, and 3 (6%) studies had 4 groups. A usual care control group was used in 43 (88%) studies, whereas 3 (6%) studies used a consumer device in the control group, and 4 (8%) other studies used active comparators without a consumer device (eg, counseling alone). Statistical power analyses were conducted a priori in 39 of the 49 (80%) studies, and 29 of these 39 (74%) studies were based on SBP, DBP, or BP control. Note that 31 of the 49 (62%) studies used only multicomponent interventions, making it impossible to discern the impact specific to the BP monitor. Among these 31 studies, 25 (81%) used a BP monitor along with nondevice interventions, 3 (10%) studies used a BP monitor along with another device, and the other 4 (12%) studies used a BP monitor along with ≥2 other devices.
Table 2

Patient characteristics in studies isolating the effect of blood pressure monitors.

StudyAge (years), meanSample (female), nFemale, n (%)Baseline disease severity
Aekplakorn et al (2016) [13]59224148 (66)

Mean SBPa PGHDb: 149.4 mm Hg

Mean DBPc PGHD: 83.4 mm Hg

Mean SBP UCd: 147.2 mm Hg

Mean DBP UC: 82.2 mm Hg

Bosworth et al (2009) [14]61636420 (66)

BP controlled at baseline 73%

Mean SBP: 125 mm Hg

Mean DBP: 71 mm Hg

Bosworth et al (2011) [15]; Bosworth et al (2007) [16]; Bosworth et al (2008) [17]61636407 (64)

Mean SBP: 125 mm Hg

Mean DBP: 71 mm Hg

Broege et al (2001) [18]734028 (70)

Mean ambulatory awake SBP: 147 mm Hg

Mean ambulatory awake DBP: 82 mm Hg

Fuchs et al (2012) [19]59.012173 (60)

Mean office SBP: 158.6 mm Hg

Mean office DBP: 89.5 mm Hg

Mean 24-hour systolic ABPMe: 148.8 mm Hg

Mean 24-hour diastolic ABPM: 87.5 mm Hg

Green et al (2008) [20,21]59.1778405 (52)

Mean SBP: 151.9 mm Hg

Mean DBP: 89.1 mm Hg

Hebert et al (2012) [22]60.8416295 (71)

Mean SBP: 153 mm Hg

Mean DBP: 86.0 mm Hg

Hoffmann-Petersen et al (2017) [23]60.5356164 (46)

Mean office SBP: 154.6 mm Hg

Mean office DBP: 93.2 mm Hg

Hosseininasab et al (2014) [24]58.7194118 (61)

Mean SBP: 145.2 mm Hg

Mean DBP: 85.3 mm Hg

Kaihara et al (2014) [25]64.45737 (65)

Mean SBP: 144 mm Hg

Mean DBP: 83 mm Hg

Kauric-Kleinet et al (2007) [26]48.73423 (68)

Mean SBP PGHD: 161 mm Hg and 162 mm Hg in the UC group

Mean DBP PGHD: 94 mm Hg

Mean DBP UC: 100 mm Hg

Patients were chronic hemodialysis patients

Kim et al (2016) [27]; Bloss (2016) [28]57.6160104 (65)

Mean SBP: 140.6 mm Hg

Mean DBP: 89.4 mm Hg

Mean number of antihypertensive medications: 2

Lakshminarayan et al (2018) [29]665014 (28)

Mean SBP: 140 mm Hg

Mean DBP: not reported

Márquez-Contreras et al (2006) [30]59.1250123 (49)

Mean SBP: 157.4 mm Hg

Mean DBP: 91.7 mm Hg

McManus et al (2018) [4,31-33]66.91173540 (46)

Mean SBP: 153.1 mm Hg

Mean DBP: 85.5 mm Hg

Qi et al (2017) [34]64.01032464 (45)

Mean SBP: 140.0 mm Hg

Mean DBP: 92.5 mm Hg

Zaleski et al (2019) [35]52.32413 (54)

Mean SBP: 136.2 mm Hg

Mean DBP: 85.2 mm Hg

Mean duration of hypertension: 6.2 years

Zha et al (2019) [36]52.22522 (88)

Mean SBP: 145.72 mm Hg

Mean DBP: 90.57 mm Hg

aSBP: systolic blood pressure.

bPGHD: patient-generated health data.

cDBP: diastolic blood pressure.

dUC: usual care.

eABPM: ambulatory blood pressure monitoring.

General characteristics of studies isolating the effect of blood pressure monitors. PGHDc (Omron HEM 7117) Usual care Surrogate (SBPd, DBPe, or BP control) Process Consumer experience PGHD (Omron 773AC or 637) Behavioral intervention Combination (PGHD+behavioral) Usual care Health (hospitalizations) Surrogate (SBP, DBP, or BP control) Process Adverse events Consumer experience PGHD (Omron 773AC or 637) Behavioral intervention Combination (PGHD+behavioral) Usual care Surrogate (SBP or DBP) PGHD (Omron HEM-702) Usual care Health (QoLf) Surrogate (SBP or DBP) Consumer experience PGHD (Omron HEM-705 CP) Usual care Surrogate (SBP or DBP) Consumer experience PGHD (Omron HEM-705 CP) Combination (PGHD+pharmacist care) Usual care Health (QoL) Surrogate (SBP, DBP, or BP control) Adverse events PGHD (Omron HEM-712C) Combination (PGHD+nurse management) Usual care Health (mortality) Surrogate (SBP, DBP, or BP control) Process PGHD (A&D 767PlusBT or Omron 705IT) Usual care Surrogate (SBP, DBP, or BP control) Process PGHD (Samsung SHB-200w) Usual care Surrogate (SBP or DBP) PGHD (Omron HEM-7251G) Conventional BP monitor Surrogate (SBP or DBP) Consumer experience PGHD (Omron IC) Usual care Surrogate (SBP or DBP) PGHD (Withings) Usual care Surrogate (SBP, DBP, or BP control) Consumer experience PGHD (upper arm Withings [Nikia] wireless BP monitor) Conventional BP monitor Surrogate (SBP) Consumer experience PGHD (Omron M4 automatic monitor) Usual care Surrogate (SBP, DBP, or BP control) PGHD (Omron M10-IT) Combination (PGHD+telemonitoring) Usual care Health (QoL) Surrogate (SBP or DBP); process Adverse events PGHD (Omron HEM-7121) Control group Surrogate (SBP, DBP, or BP control) PGHD (BP Omron 705 CPN) Usual care Surrogate (SBP or DBP) Adverse events Consumer experience PGHD (iHealth BP 7 wireless BP wrist monitor) Usual care Health (QoL) Surrogate (SBP, DBP, or BP control) Consumer experience aBP: blood pressure. bRCT: randomized controlled trial. cPGHD: patient-generated health data. dSBP: systolic blood pressure. eDBP: diastolic blood pressure. fQoL: quality of life. Patient characteristics in studies isolating the effect of blood pressure monitors. Mean SBPa PGHDb: 149.4 mm Hg Mean DBPc PGHD: 83.4 mm Hg Mean SBP UCd: 147.2 mm Hg Mean DBP UC: 82.2 mm Hg BP controlled at baseline 73% Mean SBP: 125 mm Hg Mean DBP: 71 mm Hg Mean SBP: 125 mm Hg Mean DBP: 71 mm Hg Mean ambulatory awake SBP: 147 mm Hg Mean ambulatory awake DBP: 82 mm Hg Mean office SBP: 158.6 mm Hg Mean office DBP: 89.5 mm Hg Mean 24-hour systolic ABPMe: 148.8 mm Hg Mean 24-hour diastolic ABPM: 87.5 mm Hg Mean SBP: 151.9 mm Hg Mean DBP: 89.1 mm Hg Mean SBP: 153 mm Hg Mean DBP: 86.0 mm Hg Mean office SBP: 154.6 mm Hg Mean office DBP: 93.2 mm Hg Mean SBP: 145.2 mm Hg Mean DBP: 85.3 mm Hg Mean SBP: 144 mm Hg Mean DBP: 83 mm Hg Mean SBP PGHD: 161 mm Hg and 162 mm Hg in the UC group Mean DBP PGHD: 94 mm Hg Mean DBP UC: 100 mm Hg Patients were chronic hemodialysis patients Mean SBP: 140.6 mm Hg Mean DBP: 89.4 mm Hg Mean number of antihypertensive medications: 2 Mean SBP: 140 mm Hg Mean DBP: not reported Mean SBP: 157.4 mm Hg Mean DBP: 91.7 mm Hg Mean SBP: 153.1 mm Hg Mean DBP: 85.5 mm Hg Mean SBP: 140.0 mm Hg Mean DBP: 92.5 mm Hg Mean SBP: 136.2 mm Hg Mean DBP: 85.2 mm Hg Mean duration of hypertension: 6.2 years Mean SBP: 145.72 mm Hg Mean DBP: 90.57 mm Hg aSBP: systolic blood pressure. bPGHD: patient-generated health data. cDBP: diastolic blood pressure. dUC: usual care. eABPM: ambulatory blood pressure monitoring. Table 2 (isolated-effect studies) and Multimedia Appendix 1 (Table S2; multicomponent studies) show the patient characteristics from the 49 studies. The mean age ranged from 49 to 73 years, and the percentage of females ranged from 5% to 88%. The mean baseline SBP was reported in 44 (90%) studies and ranged from 125 to 161 mm Hg. The mean baseline DBP was reported in 42 (86%) studies and ranged from 71 to 97 mm Hg. Only 3 (6%) studies were conducted in rural populations [25,37,38], whereas 24 (49%) were not of rural populations [22,23,26,29,30,35,36,39-62] and the other 22 (44%) did not specify. Only 21 of the 49 (43%) studies reported health outcomes, which included mortality (n=3 studies, 6%), hospitalizations or emergency room visits (n=2 studies, 4%), QoL (n=13 studies, 26%), and AEs (n=13 studies, 26%). No studies reported other health outcomes related to hypertension, such as major adverse cardiovascular events. All studies reported SBP, DBP, or BP control.

Device Characteristics

The included studies used 41 different BP monitoring devices (see specifics in Table 1). Of these, 34 (83%) were arm devices and 2 (5%) were wrist devices, and the wrist or arm was unclear in the other 5 (12%) studies. A total of 38 (93%) BP monitors were judged as similar to devices currently on the market from the corresponding manufacturer, 1 (2%) was judged as somewhat different, and 2 (5%) were of unknown similarity. Regarding the transmission of data (eg, to a website, to study staff, or to health care providers), 19 of 49 (39%) studies used automatic transmission, 6 (12%) used manual data entry for transmission, 20 (41%) had no electronic data transmission, and the other 4 (8%) did not report whether or how data were transmitted.

Isolated Effects on Health Outcomes

The isolated effects of a consumer BP monitor device on health outcomes were evaluated in 6 of the 49 (12%) studies. The consumer BP monitors examined included the iHealth BP 7 Wireless Wrist Monitor, Omron 637, Omron 773AC, Omron HEM-705 CP, Omron HEM-712C, and Omron M10-IT. Only 1 of the 6 (17%) studies reported mortality [22], 1 (17%) reported hospitalization [14], and the other 4 (67%) reported QoL [4,18,20,21,31-33,36]. For mortality, Hebert et al [22] followed patients for 18 months and found that 8 deaths occurred in the 3 study groups (Omron HEM-712C BP monitor, Omron HEM-712C BP monitor plus nurse management, and usual care). Mortality rates did not differ significantly across the groups (group-specific rates were not reported). For hospitalizations, Bosworth et al [14] reported no statistically significant differences in hospitalization rates among the 4 study groups. The rates ranged from 19% to 23% (group-specific rates were not reported). The groups received Omron 773AC or 637 (depending on patient arm circumference) compared with usual care, behavioral management alone, or a combination of BP monitoring and behavioral management. For QoL, 3 of the 4 (75%) studies found no statistically significant differences between groups at follow-ups ranging from 3 to 12 months. To measure QoL, the studies used the Short Form Health Survey 36 (SF-36) [18], the Short Form Health Survey-12 [20,21], or the EQ-5D [4,31-33]. The fourth study [36] found that at both baseline and the 6-month follow-up, there was a statistically significant difference in SF-36 scores favoring the usual care group over the BP monitor group (suggesting a problem with randomization rather than an effect of the BP monitor).

Isolated Effects on Surrogate Outcomes

Of the 49 studies, 18 (37%) [4,13-26,28-36] examined the isolated effects of consumer BP monitors on blood pressure. All evaluated the effects compared with usual care (ie, no BP monitor), except for 2 (11%) studies [25,29], each of which compared BP monitors with automatic data transmission with BP monitors without automatic transmission. All 16 studies on comparisons with usual care reported the effects of PGHD interventions on SBP (Figure 2). The top 4 points were from studies using automatic transmission of BP data, and the remaining 28 points were from studies that did not use automatic transmission. Six studies [4,15-17,19-21,26,31-34] found a statistically significant reduction in SBP favoring the BP monitoring group compared with the control group. However, the results were somewhat inconsistent. For example, Bosworth et al [15-17] found significant improvement only in non-White patients at 12 months; differences were not statistically significant for White patients at any time point or 24 months for any subgroup. The point estimates for SBP are shown in Figure 2, corresponding to 32 reported outcomes from 16 studies. Moreover, 4 of 32 (13%) SBP outcomes identified a reduction of 6 mm Hg or more favoring the consumer BP monitor group compared with usual care; 12 (38%) identified an SBP reduction between 2 mm Hg and 6 mm Hg favoring the consumer BP monitor, 10 (31%) identified SBP differences from −2 mm Hg to +2 mm Hg, and the remaining 3 (9%) found an SBP reduction ≥2 mm Hg favoring the usual care groups. Whether the BP monitor automatically transmitted data (comparing the top 4 points with the other points) did not appear to modify the effect on SBP.
Figure 2

Systolic blood pressure (SBP) differences in studies of isolated effects of blood pressure (BP) monitors. PGHD: patient-generated health data.

The overall findings for DBP were similar to those for SBP; 5 (31%) [4,15,19,30-34] studies found that consumer BP monitors significantly reduced DBP compared with controls. However, similar to SBP, the results were inconsistent, and statistical significance was found only for particular subgroups or time points in a study. The 32 point estimates for DBP are shown in Figure 3 (restricted to studies with usual care comparison groups). Of these, 1 (3%) identified a DBP reduction of 6 mm Hg or more favoring the consumer BP monitor, 9 (28%) identified a DBP reduction between 2 mm Hg and 6 mm Hg, favoring the consumer BP monitor, and the remaining 19 (59%) identified DBP differences from −2 mm Hg to +2 mm Hg. Whether the BP monitor automatically transmitted data did not appear to modify its effect on DBP.
Figure 3

Diastolic blood pressure (DBP) differences in studies of isolated effects of blood pressure (BP) monitors. PGHD: patient-generated health data.

Regarding the 2 studies examining the effect of data transmission (eg, BP monitor with vs without data transmission), Kaihara et al [25] found that data transmission resulted in an estimated 6 mm Hg lower SBP but no statistically significant effect on DBP. Lakshminarayan et al [29] found a statistically nonsignificant difference of 3.7 mm Hg in favor of data transmission and did not report data on DBP. BP control was examined in 9 (15%) studies of the isolated effects of consumer BP monitors [13,14,19-23,27,28,30,34]. Most defined BP control as SBP <140 mm Hg and DBP <90 mm Hg, but 1 study [23] used <135/<85 mm Hg; 2 [14,23] studies included a separate definition of <130/80 mm Hg for patients with diabetes. Only 2 of the 9 (22%) studies [19,34] reported statistically significantly higher rates of BP control with BP monitors than with controls. Fuchs et al [19] found that at 60 days, the BP control rates measured in the office were similar for BP-monitored patients and usual care patients (43% and 41%, respectively), but for 24-hour BP, 32% of BP-monitored patients had BP control compared with only 16% of usual care patients; Qi et al [34] found that at 5 years, 85% of BP-monitored patients had BP control compared with 80% of usual care patients. The remaining 7 (78%) studies found nonsignificant differences in BP control rates between BP-monitored and control patients. Systolic blood pressure (SBP) differences in studies of isolated effects of blood pressure (BP) monitors. PGHD: patient-generated health data. Diastolic blood pressure (DBP) differences in studies of isolated effects of blood pressure (BP) monitors. PGHD: patient-generated health data.

Isolated Effects on Process Outcomes

Of the 18 studies on isolated effects of BP monitors, 5 (28%) reported process outcomes, and the results were mixed. For medication prescribing, McManus et al [4,31-33] found that those in the BP monitor group were prescribed statistically significantly more antihypertensive drugs than those in the usual care group (difference 0.11; 95% CI 0.02-0.19), and 3 other studies found no statistically significant impact of BP monitoring on prescriptions. Hebert et al [22] reported that the percentage of patients who had no change in medications at 9 months was not statistically significantly different among those who had BP monitoring (44%) compared with the control group (38%). Hoffmann-Petersen et al [23] found that at baseline, 59% of the BP-monitored group and 61% of the control group did not receive any antihypertensive medication. At follow-up, these percentages were reduced to 23% in the BP-monitored group and 22% in the control group (not a significant difference). Aekplakorn et al [13] found that prescription of antihypertensive medications increased in both groups, but there were no significant between-group differences in drug items or drug classes (the authors did not report the number of prescriptions at follow-up). However, these studies were not statistically powered to detect such effects, so they did not rule out the possibility of an impact on prescriptions. In addition, Bosworth et al (2009) [14] found no between-group differences in the number of outpatient encounters (medians ranged from 13 to 15). With regard to data transmission, 5 of the 18 (28%) studies used automatic data transmission, 2 (11%) used manual entry, 10 (31%) had no electronic data transmission, and 1 (3%) did not report whether or how data were transmitted. Of those using automatic data transmission, in Hoffmann-Petersen et al [23], data were transmitted using a Tunstall RTX3371 or Numera telehealth monitor to a study database or an electronic health record after BP measurements. In Kaihara et al [25], the BP monitor wirelessly transmitted data to a study database over the internet. In Kim et al [27], the BP monitor readings were wirelessly transmitted via the HealthCircles app on a smartphone to a website. In Lakshminarayan et al [29], a smartphone transmitted daily BP measurements to a study database. Participants in the PGHD group transmitted data on an average of 89% of the study days and rated the ease of use of the system favorably. In Zha et al [36], the wireless BP wrist monitor would transmit data to a website using the iHealth MyVitals app on a smartphone. Of the 18 studies, 2 (18%) studies used manual data transmission [4,35]. In these 2 studies, participants sent BP readings via an SMS text message service or web-based form to a website [4] or entered their BP measurements on a BP-tracking website [35].

Adverse Events

Of the 49 studies, 12 (24%) reported on AEs and generally found them to occur infrequently, and 4 [4,14,20,21,31-33,35] of the 18 (22%) studies on isolated effects of BP monitoring reported on AEs; 2 (17%) studies reported that no AEs occurred during the course of the study. A study [20,21] found that serious AEs, including nonfatal cardiovascular events, were rare and not substantially different between the BP monitoring and control groups. Another study [4,31-33] reported on various other AEs, including pain, fatigue, and dry mouth. Only dry mouth occurred significantly more frequently in the BP monitor group than in the usual care group. Of the 49 studies, 11 (22%) [4,14,20,21,31-33,38,44-46,50-56,60,63-74] reported on AEs in studies with multicomponent device groups. Only one of those studies [69-73] reported a significant increase of an AE, swelling of legs, in a multicomponent intervention group that included a BP monitor compared with usual care.

Consumer Experience

Of the 49 studies, 26 (53%) reported the outcomes of consumer experience. Adherence to the use of BP monitors ranged from 38% to 89%, but device adherence had variable definitions. For example, Logan et al [47] defined adherence as a minimum of 8 readings per week. Zaleski et al [35] only determined whether patients said they were still monitoring their BP. Zha et al [36] measured adherence by dividing the number of received readings by expected readings. Some studies reported that adherence declined throughout the study. For example, Bosworth et al [14] reported that during the first 2 months, 91% of those using a BP monitor were adherent, whereas 64% were adherent during the last 2 months. The studies also measured BP monitor use in various ways, including the total number of transmissions during the study and the average number of transmissions per week. Studies measuring the ease of use or satisfaction with consumer BP monitors found favorable ratings. For example, Magid et al [49] reported that 68% of patients using the monitor found it very or extremely easy to use. Rifkin et al [75] reported that 96% of patients would continue to use the BP monitor. Only 2 studies reported problems with BP monitors. Bosworth et al [63-65] found that 35 alerts were triggered by the monitoring system due to BP monitor problems, which represented 5% of the total alerts that occurred during the study. Lakshminarayan et al [29] found that some patients experienced issues with the BP monitor and the smartphone provided to transmit BP data, including an inability to hold a charge and difficulty using the phone app to see BP data.

Multicomponent Effects

Of the 31 multicomponent studies [38-87], 11 (35%) examined the multicomponent effect of BP monitors on health outcomes, and all 31 evaluated multicomponent PGHD for surrogate outcomes including SBP, DBP, and BP control. These study designs did not permit any determination of the effectiveness specific to BP monitors.

Risk of Bias

Of the 18 studies of isolated effects, we rated 6 (33%) as low risk of bias, 9 (50%) as moderate risk of bias, and 3 (17%) as high risk of bias. In contrast, of the 31 studies of multicomponent effects, we rated 6 (19%) as low risk of bias, 13 (42%) as moderate risk of bias, and 12 (39%) as high risk of bias. The full AHRQ report (in its Appendix Table C-26) contains the item-level and overall risk-of-bias ratings for each study [7].

Discussion

Principal Findings

This systematic review summarizes 49 comparative studies that used consumer BP monitors for hypertension management. However, the effects of these devices on health outcomes remain unclear. Only 18 studies were designed to isolate the BP monitor effect, and only 6 of these 18 (33%) studies reported any health outcome, such as mortality, hospitalization, and QoL. One study [36] found a statistically significant difference in QoL at follow-up favoring usual care over BP monitoring, but QoL also favored usual care at baseline (suggesting a problem in the randomization process). None of the 5 remaining studies found statistically significant effects on health outcomes, possibly because they were powered to detect differences in BP measurements and not necessarily differences in health outcomes. Many studies had only 6 months of follow-up, which may also explain the uncertain effect of BP monitors on health outcomes. We found consistent benefits of BP monitoring on both surrogate outcomes, SBP and DBP. SBP reductions typical of included studies ranged between 2 and 4 mm Hg, and DBP reductions ranged from 1 to 3 mm Hg. It is unclear whether these modest changes in BP related to consumer BP monitors lead to lower risks of hypertension-related complications or mortality. Many factors may have potentially modified BP reduction in these studies. BP self-monitoring may support behavioral changes or reminder strategies to assist with lifestyle changes or medication adherence [2-4]. In addition, select BP monitors transmit data to health care providers and can improve BP control by facilitating timely recommendations from providers to patients to better manage their BP [87,88]. However, only 5 [23,25,27-29,36] of the 18 (27%) studies on isolated effects of BP monitors used automatic data transmission, and the effects on provider behavior change were rarely described among the included studies. This indicates that many studies did not use the advanced capabilities of modern BP monitors and may explain the unclear impact on health outcomes. Most studies reported adherence to BP monitor use that ranged from 38% to 89%, but adherence was inconsistently measured. There was also a large gap between self-reported and measured adherence, such as a set number of recordings per week, as self-reported information is not always reliable. In addition, adherence can be affected by a variety of factors, such as daily access to the device, consumer comfort with the device, or self-motivation factors [89]. Spillover to other adherence factors, such as medication adherence or compliance with lifestyle behavior changes to manage hypertension, were not reported but may ultimately be a mechanism by which consumers of BP monitors improve their hypertension. Another consumer experience outcome, overall satisfaction, was reported as highly favorable among the included studies, thus validating the current rising consumer market for these devices. Many studies evaluated multicomponent interventions, with BP monitors representing only 1 component, and did not separately evaluate the impact of the BP monitor. In our evidence base, only 18 of the 49 (37%) studies permitted such a direct assessment of BP monitor impact. Many PGHD technologies are intended to be used in combination with other interventions for chronic disease management, such as additional devices, exercise sessions, or health education sessions with medical personnel. These interventions may also influence outcomes; therefore, studies should be designed to measure the impact of isolated PGHD technology when added to other components.

Strengths and Limitations

This systematic review has several strengths. To our knowledge, this is the first systematic review to synthesize the patient-centered health effects of consumer BP monitors for hypertension management, in addition to their effects on BP. We closely followed the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) reporting standards and used robust AHRQ Evidence-based Practice Center systematic review methodology, including duplicate literature screening and data extraction. The findings of our review mirror those from 2 recent meta-analyses of systematic reviews of individual patient data [90,91] and contribute summary-level data on health effects as well as key data on medication management and consumer experience. Furthermore, in this review, we used device engineers to verify the consumer availability of BP monitors used in studies and their similarity to currently available models. This systematic review has limitations related to both the review methodology and the generalizability of the available literature. We judged the overall risk of bias using an adapted tool designed for mobile apps in managing diabetes [8] and therefore may not have detected some biases. We did not assess the possibility of publication bias, which may be a key problem in studies funded by manufacturers of devices that collect PGHD. The included studies rarely provided sufficient detail to delineate the contributions of cointerventions to outcomes, particularly those related to changes in BP. This limits the generalizability of our findings to patients with limited access to care or underserved patient populations. This may also further limit the confidence in the validity of our findings not otherwise captured in our risk-of-bias assessment. Studies with usual care groups often provided few details about what happened with these patients, which may potentially explain the wide variation in BP results among studies. The inclusion criteria of multiple studies were specific to consumers who had access to and familiarity with technology, which could include using the internet, smartphones or computers, arm or wrist devices, or access to electricity. Less technically adept consumers may not experience the same benefits as those enrolled in these studies. In addition, only 3 [25,37,38] of the 49 (6%) studies focused on rural populations, suggesting that these populations are underrepresented. Only 19 of the 49 (39%) studies used automatic data transmission from PGHD devices to health care providers. Future studies are needed to examine the effectiveness of BP monitors that transmit data to health care providers (which are then used to inform medical decisions). Additional data from implementation studies may help determine which components are critical for sustained BP improvement, which in turn may improve prescription decisions by clinicians and coverage decisions by policy makers. In addition, challenges related to data accuracy, interoperability, privacy, and security should be explored as this field continues to grow.
  85 in total

1.  Using mHealth for the management of hypertension in UK primary care: an embedded qualitative study of the TASMINH4 randomised controlled trial.

Authors:  Sabrina Grant; James Hodgkinson; Claire Schwartz; Peter Bradburn; Marloes Franssen; Fd Richard Hobbs; Sue Jowett; Richard J McManus; Sheila Greenfield
Journal:  Br J Gen Pract       Date:  2019-08-29       Impact factor: 5.386

2.  Performance and persistence of a blood pressure self-management intervention: telemonitoring and self-management in hypertension (TASMINH2) trial.

Authors:  E P Bray; M I Jones; M Banting; S Greenfield; F D R Hobbs; P Little; B Williams; R J Mcmanus
Journal:  J Hum Hypertens       Date:  2015-01-08       Impact factor: 3.012

3.  DASH to wellness: emphasizing self-regulation through e-health in adults with prehypertension.

Authors:  Ashley E Dorough; Richard A Winett; Eileen S Anderson; Brenda M Davy; Emily C Martin; Valisa Hedrick
Journal:  Health Psychol       Date:  2012-11-26       Impact factor: 4.267

4.  Effect of pharmacist intervention and initiation of home blood pressure monitoring in patients with uncontrolled hypertension.

Authors:  B M Mehos; J J Saseen; E J MacLaughlin
Journal:  Pharmacotherapy       Date:  2000-11       Impact factor: 4.705

5.  Home blood pressure monitoring with nurse-led telephone support among patients with hypertension and a history of stroke: a community-based randomized controlled trial.

Authors:  Sally M Kerry; Hugh S Markus; Teck K Khong; Geoffrey C Cloud; Jenny Tulloch; Denise Coster; Judith Ibison; Pippa Oakeshott
Journal:  CMAJ       Date:  2012-11-05       Impact factor: 8.262

6.  Evaluation of a mobile phone telemonitoring system for glycaemic control in patients with diabetes.

Authors:  Robert S H Istepanian; Karima Zitouni; Diane Harry; Niva Moutosammy; Ala Sungoor; Bee Tang; Kenneth A Earle
Journal:  J Telemed Telecare       Date:  2009       Impact factor: 6.184

7.  A multifaceted pharmacist intervention to improve antihypertensive adherence: a cluster-randomized, controlled trial (HAPPy trial).

Authors:  K Stewart; J George; K P Mc Namara; S L Jackson; G M Peterson; L R Bereznicki; P R Gee; J D Hughes; M J Bailey; Ys A Hsueh; J M McDowell; D A Bortoletto; R Lau
Journal:  J Clin Pharm Ther       Date:  2014-06-19       Impact factor: 2.512

8.  Feasibility of blood pressure telemonitoring in patients with poor blood pressure control.

Authors:  Felicia McCant; Gwendolyn McKoy; Janet Grubber; Maren K Olsen; Eugene Oddone; Benjamin Powers; Hayden B Bosworth
Journal:  J Telemed Telecare       Date:  2009       Impact factor: 6.184

9.  A Web-Based Self-Titration Program to Control Blood Pressure in Patients With Primary Hypertension: Randomized Controlled Trial.

Authors:  Chi-Wen Kao; Ting-Yu Chen; Shu-Meng Cheng; Wei-Shiang Lin; Yue-Cune Chang
Journal:  J Med Internet Res       Date:  2019-12-05       Impact factor: 5.428

10.  Two self-management interventions to improve hypertension control: a randomized trial.

Authors:  Hayden B Bosworth; Maren K Olsen; Janet M Grubber; Alice M Neary; Melinda M Orr; Benjamin J Powers; Martha B Adams; Laura P Svetkey; Shelby D Reed; Yanhong Li; Rowena J Dolor; Eugene Z Oddone
Journal:  Ann Intern Med       Date:  2009-11-17       Impact factor: 25.391

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.