Literature DB >> 3549670

Hemodynamic, gas exchange, and hormonal consequences of LBPP during PEEP ventilation.

D M Payen, C J Brun-Buisson, P A Carli, Y Huet, F Leviel, L Cinotti, B Chiron.   

Abstract

Hemodynamic, gas exchange, and hormonal response induced by application of a 25- to 40-mmHg lower body positive pressure (LBPP), during positive end-expiratory pressure (PEEP; 14 +/- 2.5 cmH2O) were studied in nine patients with acute respiratory failure. Compared with PEEP alone, LBPP increased cardiac index (CI) from 3.57 to 4.76 l X min-1 X m-2 (P less than 0.001) in relation to changes in right atrial pressure (RAP) (11 to 16 mmHg; P less than 0.01). Cardiopulmonary blood volume (CPBV) measured in five patients increased during LBPP from 546 +/- 126 to 664 +/- 150 ml (P less than 0.01), with a positive linear relationship between changes in RAP and CPBV (r = 0.88; P less than 0.001). Venous admixture (Qva/QT) decreased with PEEP from 24 to 16% (P less than 0.001) but did not change with LBPP despite the large increase in CI, leading to a marked O2 availability increase (P less than 0.001). Although PEEP induced a significant rise in plasma norepinephrine level (NE) (from 838 +/- 97 to 1008 +/- 139 pg/ml; P less than 0.05), NE was significantly decreased by LBPP to control level (from 1,008 +/- 139 to 794 +/- 124 pg/ml; P less than 0.003). Plasma epinephrine levels were not influenced by PEEP or LBPP. Changes of plasma renin activity (PRA) paralleled those of NE. No change in plasma arginine vasopressin (AVP) was recorded. We concluded that LBPP increases venous return and CPBV and counteracts hemodynamic effects of PEEP ventilation, without significant change in Qva/QT. Mechanical ventilation with PEEP stimulates sympathetic activity and PRA apparently by a reflex neuronal mechanism, at least partially inhibited by the loading of cardiopulmonary low-pressure reflex and high-pressure baroreflex. Finally, AVP does not appear to be involved in the acute cardiovascular adaptation to PEEP.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3549670     DOI: 10.1152/jappl.1987.62.1.61

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  7 in total

1.  Heart-lung interactions, a long story with many pioneers.

Authors:  Didier Payen
Journal:  Ann Transl Med       Date:  2018-09

2.  Comparing hemodynamic effects with three different measurement devices, of two methods of external leg compression versus passive leg raising in patients after cardiac surgery.

Authors:  Mochamat Helmi; Rob B P de Wilde; Jos R C Jansen; Bart F Geerts; Michel I M Versteegh; Paul C M van den Berg; Diederik Gommers; A B Johan Groeneveld
Journal:  J Clin Monit Comput       Date:  2012-11-10       Impact factor: 2.502

3.  Lower body positive pressure application with an antigravity suit in acute carotid occlusion.

Authors:  Karine Berthet; Anne Claire Lukaszewicz; Marie-Germaine Bousser; Didier Payen
Journal:  Stroke Res Treat       Date:  2010-04-01

Review 4.  Renal hypoxia and dysoxia after reperfusion of the ischemic kidney.

Authors:  Matthieu Legrand; Egbert G Mik; Tanja Johannes; Didier Payen; Can Ince
Journal:  Mol Med       Date:  2008 Jul-Aug       Impact factor: 6.354

5.  Prediction of fluid challenge effect: filling pressure when left ventricular function is abnormal, diastolic volume when left ventricular function is normal.

Authors:  Didier Payen
Journal:  Crit Care       Date:  2011-03-24       Impact factor: 9.097

Review 6.  Functional hemodynamic monitoring.

Authors:  Michael R Pinsky; Didier Payen
Journal:  Crit Care       Date:  2005-11-22       Impact factor: 9.097

7.  The effect of continuous positive airway pressure (CPAP) on renal vascular resistance: the influence of renal denervation.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.