Literature DB >> 35495557

Transcatheter Treatment of Ascending Aorta Pseudoaneurysm Guided by 3D-Model Technology.

Giuseppe Santoro1, Antonio Rizza2, Alessandra Pizzuto1, Sergio Berti2, Magdalena Cuman1, Emanuele Gasparotti3, Katia Capellini3, Massimiliano Cantinotti1, Alberto Clemente4, Simona Celi3.   

Abstract

Ascending aorta pseudoaneurysm is a rare but potentially life-threatening complication of atherosclerosis, infections, chest trauma, transcatheter or surgical interventions. Due to high surgical risk, percutaneous closure is considered a valuable cost-effective therapeutic alternative. In this setting, 3D printing technology is emerging as a powerful tool to plan transcatheter repair. (Level of Difficulty: Advanced.).
© 2022 The Authors.

Entities:  

Keywords:  3D printing; 3D, 3-dimensional; AAP, ascending aorta pseudoaneurysm; CT, computed tomography; aorta; device; pseudoaneurysm

Year:  2022        PMID: 35495557      PMCID: PMC9040102          DOI: 10.1016/j.jaccas.2022.01.005

Source DB:  PubMed          Journal:  JACC Case Rep        ISSN: 2666-0849


Ascending aorta pseudoaneurysm (AAP) is a rare but potentially life-threatening complication of atherosclerosis, infections, blunt chest trauma, transcatheter procedures, or, more frequently, surgical interventions., It may remain clinically silent for a long time until compression of the surrounding structures, infection, distal embolization, mass fistulation, or life-threatening rupture ensue. Thus, symptoms or the potential for complications mandate emergent repair at the diagnosis. Because surgical treatment is still burdened by high morbidity and mortality, the transcatheter option has emerged as a safer and cost-effective therapeutic alternative. However, this approach is still technically demanding and has not been standardized because of the unpredictability and complexity of local anatomy and the lack of dedicated devices. In this setting, 3D printing technology has recently emerged as an invaluable tool in planning complex transcatheter interventions.,

Learning Objectives

To understand the incidence, pathogenesis, and potential transcatheter treatment of ascending aorta pseudoaneurysm. To show the usefulness of 3D technology in planning interventional (surgical or transcatheter) repair in patients in critical condition with challenging, life-threatening cardiac anomalies. To highlight the potentiality of 3D printing technology in guiding transcatheter repair of ascending aorta pseudoaneurysm in preprocedure planning and device selection. This article reports on 3 cases of postsurgical AAP successfully treated by transcatheter closure based on 3D printed models.

Case Reports

Case 1

A 70-year-old asymptomatic man was admitted in critical conditions 3 months after surgical coronary artery revascularization for severe anemia and refractory heart failure. Diagnostic workouts for hidden bleeding or abscesses showed a huge AAP (58 × 69 × 83 mm) at the site of surgical cannulation. The angio-CT scan measured an aneurysmal neck of about 9 × 7 mm (Figures 1A and 1B, Video 1) and showed compression of the main pulmonary artery and complete occlusion of the venous graft. Owing to the patient’s high surgical risk (EuroSCORE 17.3%), the percutaneous approach was deemed the therapeutic option with the highest risk–benefit profile. The patient gave informed consent for the procedure. A CT scan–based 3D model of the aortic arch was printed (Figures 1C and 1D), the careful evaluation of which made us conscious that the left subclavian artery provided the straightest vascular course to the lesion. Using this 3D model, we could fully mimic ex vivo the entire procedure (Video 2). The procedure was performed via the left brachial artery. The pseudoaneurysm was easily probed with an Amplatzer left coronary catheter and completely occluded with a 14-mm Amplatzer septal occluder device (Abbott) (Figures 2A and 2B), with sudden improvement of the patient’s hemodynamic stability. Thereafter, we were able to treat the heart failure, and the patient was discharged in good clinical condition after 18 days. The predischarge CT scan showed complete occlusion of the pseudoaneurysmal mass (Figure 2C).
Figure 1

3D Computed Tomography Scan and Printed Model of the Huge Pseudoaneurysm Compressing the Anterior Surface of the Ascending Aorta

Ascending aorta pseudoaneurysm as imaged at computed tomography scan 3D reconstruction from outside (A) and by cut-plain internal views (B). Using the cut-plain internal view, it is possible to precisely size the feeding breach of the pseudoaneurysm (asterisk). Printed 3D model of the ascending aorta and pseudoaneurysm as viewed en face (C) and from behind (D). AAo =ascending aorta; Dao = descending aorta; LPA = left pulmonary artery; LV = left ventricle; PA = main pulmonary artery; PsA = pseudoaneurysm; RV = right ventricle.

Figure 2

Angiographic and 3D Computed Tomography Scan Imaging of the Pseudoaneurysm Submitted to Device Closure

Angiographic appearance of the pseudoaneurysmal sac at the “in-situ” angiography (A). Angiographic (B) and computed tomography scan 3D reconstruction (C) of the ascending aorta after occlusion with the ASO device (asterisk). AAo = ascending aorta; PsA = pseudoaneurysm.

3D Computed Tomography Scan and Printed Model of the Huge Pseudoaneurysm Compressing the Anterior Surface of the Ascending Aorta Ascending aorta pseudoaneurysm as imaged at computed tomography scan 3D reconstruction from outside (A) and by cut-plain internal views (B). Using the cut-plain internal view, it is possible to precisely size the feeding breach of the pseudoaneurysm (asterisk). Printed 3D model of the ascending aorta and pseudoaneurysm as viewed en face (C) and from behind (D). AAo =ascending aorta; Dao = descending aorta; LPA = left pulmonary artery; LV = left ventricle; PA = main pulmonary artery; PsA = pseudoaneurysm; RV = right ventricle. Angiographic and 3D Computed Tomography Scan Imaging of the Pseudoaneurysm Submitted to Device Closure Angiographic appearance of the pseudoaneurysmal sac at the “in-situ” angiography (A). Angiographic (B) and computed tomography scan 3D reconstruction (C) of the ascending aorta after occlusion with the ASO device (asterisk). AAo = ascending aorta; PsA = pseudoaneurysm.

Case 2

A 67-year-old asymptomatic woman was referred for expanding AAP and severe aortic valve regurgitation several years after repair of a Stanford type A acute aortic dissection. During follow-up, progressive worsening of the aortic valve regurgitation and enlargement of the pseudoaneurysm of the anterior portion of the ascending aorta had been shown (Figures 3A and 3B). Owing to her high surgical risk (EuroSCORE 35.9%), a 2-step percutaneous approach of pseudoaneurysm closure and transcatheter aortic valve implantation was deemed the best cost-effective therapeutic option. The patient gave informed consent for the procedure. Thus, as is routinely done in complex cases, a CT scan–based 3D model of the aortic arch was printed (Figures 3C and 3D) to mimic ex vivo the entire procedure. The procedure was performed with the patient under general anesthesia, via the right femoral artery (Video 3). The pseudoaneurysm was probed with a steerable sheath (Agilis NXT steerable introducer) (Figure 4A) and completely occluded with a 12-mm Amplatzer vascular plug type II (Abbott) (Figures 4B and 4C). The patient was discharged 2 days after the procedure in good clinical condition and underwent successful transcatheter aortic valve implantation (Edwards Sapien3 #29) a few months later.
Figure 3

3D Computed Tomography Scan and Printed Model of the Pseudoaneurysmal Pouch Located at the Anterior Surface of the Transverse Aortic Arch

Angio-computed tomography scan 3D reconstruction of the ascending aorta showing a small pseudo-aneurysm (asterisk) as viewed from outside (A). Using the cut-plain internal view (B), it is possible to image shape and size of its feeding mouth (arrow). Printed 3D model of the ascending aorta pseudoaneurysm as viewed en face (C) and from behind (D). AAo = ascending aorta; Dao = descending aorta; TAoA = transverse aortic arch.

Figure 4

Angiographic and 3D Computed Tomography Scan Imaging of the Pseudoaneurysm Submitted to Device Closure

Pseudoaneurysmal sac (asterisk) as imaged by in situ angiography (A). Complete occlusion of the pseudoaneurysm after device implantation (arrow) as imaged at aortic angiography (B) and pre-discharge computed tomography scan 3D reconstruction (C). AAo = ascending aorta; DAo = descending aorta.

3D Computed Tomography Scan and Printed Model of the Pseudoaneurysmal Pouch Located at the Anterior Surface of the Transverse Aortic Arch Angio-computed tomography scan 3D reconstruction of the ascending aorta showing a small pseudo-aneurysm (asterisk) as viewed from outside (A). Using the cut-plain internal view (B), it is possible to image shape and size of its feeding mouth (arrow). Printed 3D model of the ascending aorta pseudoaneurysm as viewed en face (C) and from behind (D). AAo = ascending aorta; Dao = descending aorta; TAoA = transverse aortic arch. Angiographic and 3D Computed Tomography Scan Imaging of the Pseudoaneurysm Submitted to Device Closure Pseudoaneurysmal sac (asterisk) as imaged by in situ angiography (A). Complete occlusion of the pseudoaneurysm after device implantation (arrow) as imaged at aortic angiography (B) and pre-discharge computed tomography scan 3D reconstruction (C). AAo = ascending aorta; DAo = descending aorta.

Case 3

A 76-year-old man with a history of coronary artery disease, ascending aortic aneurysm, and severe aortic regurgitation was referred for progressive anemia about 2 weeks after surgical aortic valve replacement with a biologic prosthesis, ascending aorta replacement with vascular graft, and aortocoronary bypass graft. The CT scan showed severe aortic arch dilation (53 × 55 mm) and a dissecting pseudoaneurysm (1.8 × 1 × 0.7 cm, with a feeding mouth of 0.6 cm2) located at the posterolateral side of the conduit anastomosis (Figures 5A and 5B). Based on the patient’s hemodynamic instability and the high risk of surgical re-intervention (EuroSCORE 8.8%), the percutaneous approach was considered the best therapeutic option. The patient gave informed consent for the procedure. A CT scan–based 3D model of the aortic arch was printed (Figures 5C and 5D). The procedure was performed with the patient under general anesthesia, via the right femoral artery and left axillary artery. The pseudoaneurysm was probed with an Amplatzer left coronary guiding catheter and completely occluded with simultaneous implantation of 2 controlled-release coils (Cook Medical) and a 6-6 mm Amplatzer duct occluder type II device (Abbott) (Figures 6A to 6C, Video 4). The patient’s clinical condition suddenly improved, and he was discharged 4 days after the procedure with complete closure of the pseudoaneurysmal sac as shown by a control CT scan (Figure 6D).
Figure 5

3D Computed Tomography Scan and Printed Model of the Pseudoaneurysmal Sac Located at the Posterolateral Surface of the Ascending Aorta

Pseudoaneurysm (asterisk) of the posterior side of the ascending aorta as imaged at computed tomography scan 3D reconstruction from outside (A) and by cut-plain internal view (B). Printed 3D model of the ascending aorta pseudoaneurysm as viewed from behind (C) and above (D). AAo = ascending aorta; DAo = descending aorta; LV = left ventricle; RA = right atrium; RV = right ventricle; TAoA = transverse aortic arch.

Figure 6

Angiographic and 3D Computed Tomography Scan Imaging of the Pseudoaneurysm Submitted to Device Closure

Aortic angiography in right oblique view before (A, B) and after (C) closure of the pseudoaneurysmal sac with multiple devices. Complete occlusion of the pseudoaneurysm after device implantation as imaged at the predischarge computed tomography scan 3D reconstruction (D). AAo = ascending aorta; D = devices; LV = left ventricle.

3D Computed Tomography Scan and Printed Model of the Pseudoaneurysmal Sac Located at the Posterolateral Surface of the Ascending Aorta Pseudoaneurysm (asterisk) of the posterior side of the ascending aorta as imaged at computed tomography scan 3D reconstruction from outside (A) and by cut-plain internal view (B). Printed 3D model of the ascending aorta pseudoaneurysm as viewed from behind (C) and above (D). AAo = ascending aorta; DAo = descending aorta; LV = left ventricle; RA = right atrium; RV = right ventricle; TAoA = transverse aortic arch. Angiographic and 3D Computed Tomography Scan Imaging of the Pseudoaneurysm Submitted to Device Closure Aortic angiography in right oblique view before (A, B) and after (C) closure of the pseudoaneurysmal sac with multiple devices. Complete occlusion of the pseudoaneurysm after device implantation as imaged at the predischarge computed tomography scan 3D reconstruction (D). AAo = ascending aorta; D = devices; LV = left ventricle.

Comment

The transcatheter option is increasingly emerging as a safer and cost-effective alternative to surgical repair of AAP. However, this approach is still technically demanding because of the unpredictability and complexity of local anatomy and the lack of dedicated devices. Using 3D printing technology to finely detail the site, size, and shape of the feeding breach and its spatial relationship with the neighboring structures may be crucial for the success of the procedure. This approach adds several advantages to simple 3D digital reconstruction. It allows a more tangible understanding of the spatial relationship between the cardiac and extracardiac structures, making it easier to plan vascular access, entry angle to the target lesion, and device manipulation. In addition, the use of 3D printed models allows the surgeon to entirely mimic ex vivo the planned interventional procedure by testing different types of devices, decreasing procedure time, x-ray exposure, and overall risk of the treatment. In conclusion, the advantage of the 3D printing technology mainly lies in preprocedure planning of challenging percutaneous interventions. It allows prediction of any potential difficulty of the interventional procedure by giving a better knowledge of local anatomy and also testing ex vivo the performance of different off-label devices.

Funding Support and Author Disclosures

Dr Santoro has been a proctor for Abbott, WL Gore, and Occlutech. Dr Berti has been a proctor for Abbott, Boston Scientific, and Edwards. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.
  6 in total

1.  Ascending aortic pseudoaneurysm, a ticking bomb after cardiac surgery.

Authors:  Leenhapong Navaravong; Fadi Saab; James R Cook; Mark Peterman; Joseph Flack
Journal:  Cardiovasc Revasc Med       Date:  2010-10-20

Review 2.  Percutaneous closure of ascending aortic pseudoaneurysm using Amplatzer septal occluder device: the first clinical case report and literature review.

Authors:  Faran Bashir; Robert Quaife; John D Carroll
Journal:  Catheter Cardiovasc Interv       Date:  2005-08       Impact factor: 2.692

3.  Atherosclerotic pseudoaneurysm of the ascending aorta.

Authors:  Robert N Belkin; Srirama K Kalapatapu; Rocco J Lafaro; Gita Ramaswamy; John A McClung; Martin B Cohen
Journal:  J Am Soc Echocardiogr       Date:  2003-04       Impact factor: 5.251

Review 4.  Cardiac 3D Printing and its Future Directions.

Authors:  Marija Vukicevic; Bobak Mosadegh; James K Min; Stephen H Little
Journal:  JACC Cardiovasc Imaging       Date:  2017-02

5.  Pseudoaneurysms of the aorta after cardiac surgery or chest trauma.

Authors:  A Razzouk; S Gundry; N Wang; R Heyner; C Sciolaro; G Van Arsdell; R Bansal; E Vyhmeister; L Bailey
Journal:  Am Surg       Date:  1993-12       Impact factor: 0.688

6.  Transcatheter Treatment of "Complex" Aortic Coarctation Guided by Printed 3D Model.

Authors:  Giuseppe Santoro; Alessandra Pizzuto; Antonio Rizza; Magdalena Cuman; Duccio Federici; Massimiliano Cantinotti; Vitali Pak; Alberto Clemente; Simona Celi
Journal:  JACC Case Rep       Date:  2021-06-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.