| Literature DB >> 35495465 |
Xiayuan Wu1, Chunrui Li1, Zuopeng Lv2, Xiaowei Zhou3, Zixuan Chen1, Honghua Jia1, Jun Zhou1, Xiaoyu Yong1, Ping Wei1, Yan Li1.
Abstract
Cr(vi) laden wastewaters generally comprise a range of multiple heavy metals such as Au(iii) and Cu(ii) with great toxicity. In the present study, cooperative cathode modification by biogenic Au nanoparticles (BioAu) reduced from aqueous Au(iii) and in situ Cu(ii) co-reduction were investigated for the first time to enhance Cr(vi) removal in microbial fuel cells (MFCs). With the co-existence of Cu(ii) in the catholyte, the MFC with carbon cloth modified with nanocomposites of multi-walled carbon nanotubes blended with BioAu (BioAu/MWCNT) obtained the highest Cr(vi) removal rate (4.07 ± 0.01 mg L-1 h-1) and power density (309.34 ± 17.65 mW m-2), which were 2.73 and 3.30 times as high as those for the control, respectively. The enhancements were caused by BioAu/MWCNT composites and deposited reduzates of Cu(ii) on the cathode surface, which increased the adsorption capacity, electronic conductivity and electrocatalytic activity of the cathode. This study provides an alternative approach for efficiently remediating co-contamination of multiple heavy metals and simultaneous bioenergy recovery. This journal is © The Royal Society of Chemistry.Entities:
Year: 2020 PMID: 35495465 PMCID: PMC9052389 DOI: 10.1039/d0ra01471k
Source DB: PubMed Journal: RSC Adv ISSN: 2046-2069 Impact factor: 3.361
Fig. 1CV and EIS analysis of electrodes with different BioAu/MWCNT ratios (A and B) and different BioAu loading amounts (C and D) before operation.
Fig. 2SEM images of the bare (A–D) and BioAu/MWCNT ((E–H) BioAu/MWCNT ratio: 1 : 2, BioAu loading amount: 1.84 ± 0.01 mg cm−2) electrode before and after operation.
Surface characteristics of the bare and BioAu/MWCNT (BioAu/MWCNT ratio: 1 : 2, BioAu loading amount: 1.84 ± 0.01 mg cm−2) electrode
| Electrode | BET SSA (m2 g−1) | Contact angle (°) | Resistance (Ω) |
|---|---|---|---|
| Bare | 3.78 ± 0.34 | 110.4 ± 0.6 | 7.5 ± 0.7 |
| BioAu/MWCNT | 66.97 ± 0.23 | 48.2 ± 0.7 | 6.31 ± 0.9 |
Fig. 3Voltage outputs (A), power densities (B), polarization curves (C), and dissolved Cr(vi) concentration changes (D) of Cr(vi)-reducing MFCs with different cathode electrodes.
Comparison of studies on abiotic Cr(vi) reduction in two-chamber MFCsa
| No. | Anode (A)/Cathode (C) material | Initial Cr( | Other metals (mg L−1) in catholyte | Power density (mW m−2) | Cr( | Reference |
|---|---|---|---|---|---|---|
| 1 | Graphite plate (A/C) | 200, 2.0 | None | 150 | 1.06 |
|
| 2 | Graphite plate (A)/rutile-coated graphite plate (C) | 26, 2.0 | None | NA | 0.97 |
|
| 3 | Graphite felt (A)/PPy/AQS-modified graphite felt (C) | 20, 7.0 | None | 299.6 | 0.43 |
|
| 4 | LCPGE (A/C) | 100, 2.0 | None | 10 | 2.08 |
|
| 5 | AA:Ni-ACF/CNF (A/C) | 200, 2.0 | None | 1540 | 2.13 |
|
| 6 | Carbon fiber felt (A/C) | 250, 2.0 | V( | 970.2 | 0.79 |
|
| 7 | Graphite felt (A)/carbon rod (C) | 50, 1.5 | Fe( | 225 | 9.4 |
|
| 8 | Graphite felt (A)/BioAu/MWCNT modified carbon cloth (C) | 100, 2.5 | Cu( | 309.34 | 4.07 | This study |
NA: not applicable; PPy: polypyrrole; AQS: 9,10-anthraquinone-2-sulfonic acid sodium salt; LCPGE: liquid crystal polarized glass electrode; AA:Ni-ACF/CNF: alumina/nickel nanoparticles-dispersed carbon nanofiber; BioAu/MWCNT: biogenic Au nanoparticles/multi-walled carbon nanotubes.
Fig. 4Voltage outputs (A), dissolved Cr(vi) concentration changes (B), and dissolved Cu(ii) concentration changes (C) of MFCs with different cathode electrodes for different heavy metals removal.
Maximum power densities (Pmax), internal resistances, and anodic COD removal of different MFCs
| Group |
| Internal resistance (Ω) | COD removal (%) |
|---|---|---|---|
| Bare-Cr | 93.82 ± 4.79 | 259.52 ± 21.65 | 44.58 ± 2.57 |
| Bare-Cu | 80.03 ± 5.01 | 239.17 ± 26.745 | 53.21 ± 1.67 |
| Bare-CrCu | 143.60 ± 12.46 | 202.09 ± 18.64 | 57.64 ± 3.58 |
| BioAu/MWCNT-Cr | 215.39 ± 21.21 | 197.64 ± 17.55 | 68.65 ± 2.93 |
| BioAu/MWCNT-Cu | 231.38 ± 13.53 | 162.32 ± 13.86 | 70.91 ± 1.76 |
| BioAu/MWCNT-CrCu | 309.34 ± 17.65 | 124.42 ± 9.54 | 79.66 ± 4.87 |
Fig. 5XPS analysis for the deposits on the BioAu/MWCNT electrode after Cr(vi) and Cu(ii) removal ((A) full survey, (B) Cr2p, (C) Cu2p, (D) Au4f).