Literature DB >> 35479193

Ultra-sensitive ppb-level methane detection based on NIR all-optical photoacoustic spectroscopy by using differential fiber-optic microphones with gold-chromium composite nanomembrane.

Hanping Xiao1,2, Jinbiao Zhao1,2, Chaotan Sima1,2, Ping Lu1,2, Yanhong Long1, Yan Ai1, Wanjin Zhang1, Yufeng Pan1, Jiangshan Zhang3, Deming Liu1.   

Abstract

In this paper, we propose and experimentally demonstrate an ultra-sensitive all-optical PAS gas sensor, incorporating with a near-infrared (NIR) diode laser, fiber-optic microphones (FOMs) and a double channel differential T-type photoacoustic cell. The FOM is realized by Fabry-Perot interferometry and novel gold-chromium (Au-Cr) composite nanomembranes. To meet the demand of high sensitivity and flat frequency response for the FOMs, the Au-Cr composite diaphragm is deliberately designed and fabricated by E-beam evaporation deposition with 330 nm in thickness and 6.35 mm in radius. Experimental results show that the FOM has a sensitivity of about 30 V/Pa and a flat frequency response from 300 to 900 Hz with fluctuation below 1 dB. Moreover, a double channel differential T-type photoacoustic cell is designed and employed in the all-optical PAS gas sensor, with the first-order resonant frequency of 610 Hz. The all-optical gas sensor is established and verified for CH4 detection and the normalized noise equivalent absorption (NNEA) is 4.42 × 10-10 W∙cm-1∙Hz-1/2. The minimum detection limit (MDL) of 36.45 ppb is achieved with a 1 s integration time. The MDL could be further enhanced to 4.87 ppb with an integration time of 81 s, allowing ultra-sensitive trace gas detection.
© 2022 The Authors.

Entities:  

Keywords:  Fiber-optic microphone; Gas detection; Infrared; Photoacoustic spectroscopy

Year:  2022        PMID: 35479193      PMCID: PMC9035707          DOI: 10.1016/j.pacs.2022.100353

Source DB:  PubMed          Journal:  Photoacoustics        ISSN: 2213-5979


  14 in total

1.  Allan Deviation Plot as a Tool for Quartz-Enhanced Photoacoustic Sensors Noise Analysis.

Authors:  Marilena Giglio; Pietro Patimisco; Angelo Sampaolo; Gaetano Scamarcio; Frank K Tittel; Vincenzo Spagnolo
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-10-27       Impact factor: 2.725

2.  Compact photoacoustic module for methane detection incorporating interband cascade light emitting device.

Authors:  Huadan Zheng; Minhan Lou; Lei Dong; Hongpeng Wu; Weilin Ye; Xukun Yin; Chul Soo Kim; Mijin Kim; William W Bewley; Charles D Merritt; Chadwick L Canedy; Michael V Warren; Igor Vurgaftman; Jerry R Meyer; Frank K Tittel
Journal:  Opt Express       Date:  2017-07-10       Impact factor: 3.894

3.  Cavity Ring-Down Spectroscopy: Recent Technological Advancements, Techniques, and Applications.

Authors:  Abhijit Maity; Sanchi Maithani; Manik Pradhan
Journal:  Anal Chem       Date:  2020-11-16       Impact factor: 6.986

4.  Integration of T-type half-open photoacoustic cell and fiber-optic acoustic sensor for trace gas detection.

Authors:  Zhenfeng Gong; Ke Chen; Yewei Chen; Liang Mei; Qingxu Yu
Journal:  Opt Express       Date:  2019-06-24       Impact factor: 3.894

5.  Ppb-level detection of methane based on an optimized T-type photoacoustic cell and a NIR diode laser.

Authors:  Zhenfeng Gong; Tianli Gao; Liang Mei; Ke Chen; Yewei Chen; Bo Zhang; Wei Peng; Qingxu Yu
Journal:  Photoacoustics       Date:  2020-12-16

Review 6.  European guideline on indications, performance, and clinical impact of hydrogen and methane breath tests in adult and pediatric patients: European Association for Gastroenterology, Endoscopy and Nutrition, European Society of Neurogastroenterology and Motility, and European Society for Paediatric Gastroenterology Hepatology and Nutrition consensus.

Authors:  Heinz F Hammer; Mark R Fox; Jutta Keller; Silvia Salvatore; Guido Basilisco; Johann Hammer; Loris Lopetuso; Marc Benninga; Osvaldo Borrelli; Dan Dumitrascu; Bruno Hauser; Laszlo Herszenyi; Radislav Nakov; Daniel Pohl; Nikhil Thapar; Marc Sonyi
Journal:  United European Gastroenterol J       Date:  2021-08-25       Impact factor: 4.623

7.  Compact and Highly Sensitive NO2 Photoacoustic Sensor for Environmental Monitoring.

Authors:  Yufeng Pan; Lei Dong; Xukun Yin; Hongpeng Wu
Journal:  Molecules       Date:  2020-03-07       Impact factor: 4.411

View more
  3 in total

1.  Small-volume highly-sensitive all-optical gas sensor using non-resonant photoacoustic spectroscopy with dual silicon cantilever optical microphones.

Authors:  Lujun Fu; Ping Lu; Chaotan Sima; Jinbiao Zhao; Yufeng Pan; Tailin Li; Xiaohang Zhang; Deming Liu
Journal:  Photoacoustics       Date:  2022-06-30

2.  High-sensitivity miniature dual-resonance photoacoustic sensor based on silicon cantilever beam for trace gas sensing.

Authors:  Guojie Wu; Zhenfeng Gong; Junsheng Ma; Haie Li; Min Guo; Ke Chen; Wei Peng; Qingxu Yu; Liang Mei
Journal:  Photoacoustics       Date:  2022-07-16

3.  All-optical light-induced thermoacoustic spectroscopy for remote and non-contact gas sensing.

Authors:  Yufeng Pan; Jinbiao Zhao; Ping Lu; Chaotan Sima; Wanjin Zhang; Lujun Fu; Deming Liu; Jiangshan Zhang; Hongpeng Wu; Lei Dong
Journal:  Photoacoustics       Date:  2022-08-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.