Socio-economic demands and challenges for non-invasive disease diagnosis through a portable breathalyzer by the incorporation of 2D nanosheets and SMO nanocomposites.

Ramji Kalidoss1, Radhakrishnan Kothalam2, A Manikandan3,4, Saravana Kumar Jaganathan5,6,7, Anish Khan8,9, Abdullah M Asiri8,9.   

Abstract

Breath analysis for non-invasive clinical diagnostics and treatment progression has penetrated the research community owing to the technological developments in novel sensing nanomaterials. The trace level selective detection of volatile organic compounds (VOCs) in breath facilitates the study of physiological disorder and real-time health monitoring. This review focuses on advancements in chemiresistive gas sensor technology for biomarker detection associated with different diseases. Emphasis is placed on selective biomarker detection by semiconducting metal oxide (SMO) nanostructures, 2-dimensional nanomaterials (2DMs) and nanocomposites through various optimization strategies and sensing mechanisms. Their synergistic properties for incorporation in a portable breathalyzer have been elucidated. Furthermore, the socio-economic demands of a breathalyzer in terms of recent establishment of startups globally and challenges of a breathalyzer are critically reviewed. This initiative is aimed at highlighting the challenges and scope for improvement to realize a high performance chemiresistive gas sensor for non-invasive disease diagnosis. This journal is © The Royal Society of Chemistry.

Entities:  

Year:  2021        PMID: 35478818      PMCID: PMC9034087          DOI: 10.1039/d1ra02554f

Source DB:  PubMed          Journal:  RSC Adv        ISSN: 2046-2069            Impact factor:   4.036


Introduction

Disease diagnosis through exhaled breath analysis has gained momentum during the past decade as the technology offers insights about the subject's internal body metabolism without the need for sample preparation. Among other non-invasive sources (tears, sweat, urine and feces) for disease diagnosis, exhaled breath analysis seems feasible as the ancient Greek physicians had predicted that the aroma of breath provides a certain clue about diagnosis.[1,2] For instance, the smell of exhaled breath of patients with uncontrolled diabetes is often described as “rotten apple” due to the existence of acetone along with the mixture of inorganic vapors (e.g., NO, CO2etc.), volatile organic compounds (e.g., acetone, methyl nitrate, isoprene etc.) and other non-volatile vapors (e.g., nitrogen, cytokines etc.).[3] The advent of modern breath analysis came into existence when Pauling and his team in 1971 discovered more than 200 VOCs in human breath due to the biochemical pathways resulting through the physiological process.[4] Usually, this mixture of vapors along with approximately 3500 chemical species existing in human exhaled breath have been identified by various analytical techniques including gas chromatography-mass spectrometry (GC-MS), flame ionization spectrometry (FIS) and photo ionization detection (PID).[5-11] However, these methods are inadequate for routine breath biomarker monitoring as they rely on sophisticated laboratory equipment, trained technicians, and time consuming and complex sample preparation procedures leading to the lack of real time quantitative data. Thereby limiting the portability and so eliminates the possibility of point of care real time diagnosis. Hence the global scientific community had focused their efforts on developing a portable instrumentation for the real-time quantification of biomarkers for the disease diagnosis through exhaled breath. The composition of VOCs range between parts per million (ppm) to parts per billion (ppb) that varies quantitatively and qualitatively for every individual similar to unique fingerprints.[12] These VOCs may originate from cellular levels due to their fundamental body processes[13] and metabolisms in blood[14] that plays a vital role in altering the concentration of VOCs. Other sources include inhaled atmospheric air, airway surfaces and tissues throughout the body. As the blood collects all the compounds during bodily metabolism and interacts with lung, they appear in breath.[15] 54 VOCs at elevated concentration indicates several health risks related to gastrointestinal, respiratory systems and metabolic disorders such as halitosis, renal failure, diabetes, chronic liver and kidney diseases few of them listed in Table 1.[31,32] An increased concentration of ammonia is closely associated with renal disease, acetone with diabetes mellitus (DM) and nitric oxide with chronic obstructive pulmonary disease (COPD).[33] Since all this VOC appear in the breath because of certain body metabolisms, these endogenous gases resolve practical information on the possible disease and hence it is the perfect indication of any disease. Accurate quantification of these biomarkers provides the feasibility of non-invasive disease detection through exhaled breath.

List of breath biomarkers and their corresponding diseases

BiomarkerDiseaseRef.
Ethyl butanoateCOVID-19 16
AmmoniaChronic kidney disease, liver dysfunction 17 and 18
H2SHalitosis 19 and 20
NOAsthma 21 and 22
HCHO, toluene, benzeneLung cancer 23 and 24
AcetoneType 1 diabetes 25 and 26
Type 2 diabetes
CH4Intestinal anaerobes 27 and 28
EthanolAlcohol consumption 29 and 30
The availability of unlimited sample quantity even during unconsciousness may become vital in emergency situations, for continuous monitoring of disease progression and the effect of medication in short time period.[34,35] Whereas, other non-invasive sources such as saliva, sweat, urine and feces need human intervention limiting the diagnostic capabilities at the situation of emergencies. While the biomarkers from each source originate from the fundamental body metabolism, exhaled breath is reliable as it eliminates the social awkwardness or an embarrassment to the patients during sample collection. Apart from social consideration, other non-invasive sources possess certain issues in terms of stability of the sample.[36] Moreover with the capability of repeated and self sampling, breath analysis are considered to be truly non-invasive and can be performed easily without any embarrassment or discomfort.[37] Also, it does not present burden to the subject being tested and the ease of sampling offers the advantage of delivering result on spot instead of the traditional laboratory sample preparation and analysis.[38] Hence, the significance of breath analysis lies on eliminating the pre-analytical and post-analytical procedure along with the mailing of test reports to the concerned subject. Furthermore, as the biomarkers in breath appear due to the fundamental body metabolism at cellular level, diseases may be identified at early stage which is the need of the decade for different cancers that could be cured, if identified at preliminary stage.[39,40] Breath analysis may permit bedside and personalized home care monitoring, thus could be inexpensive and allows frequent testing for proper control of the disease progression and the effect of medications.[41] Thus offers an inexpensive replacement for the traditional laboratory analytical tests. However, there are numerous challenges to be addressed to bring a portable breathalyzer to the commercial market. The high complexity of breath samples leads to misinterpretation of results.[42] The exhaled biomarkers not only emanate from fundamental body processes but also from the exogenous production by different sources. Breath sampling procedure is not yet standardized leading to the unawareness of sample collection from either nasal or oral cavity. Even though, after the collection of idealized sample, extrinsic factors such as temperature and humidity may influence the outcome of the diagnosis. Furthermore, the level of data interpretation needs standardization to develop a cloud of breathprint database from laboratories across the globe representing a reference standard for clinical practices.[43] Although, limited number of breathalyzer were recognized by international guidelines and used in patients. Among them ethanol breath test, nitric oxide breath test to diagnose asthma, urea breath test for the diagnosis of Helicobacter pylori and hydrogen breathalyzer for small intestine bacterial overgrowth are currently in research practices.[44-48] Nevertheless, there is no single breath test act as stand-alone diagnostic test and only act as a pre-screening tool. Incorporation of nanomaterials in gas sensors has attracted research interests owing to their unique physic-chemical properties. Gas sensor technologies are classified based on their differences in working principle and device structures. Broadly it is categorized into technologies that rely on the change in electrical and other properties including optical, calorimetric and acoustic properties. The reliability of technologies based on variations in electrical properties such as field effect transistors (FET), surface work function transistors (SWF) and chemiresistors are suitable for exact quantification of breath biomarkers in the range of parts per billion to parts per million. Among them, chemiresistors are widely explored due to their ease in fabrication and miniaturization, simplicity in operation and demands low power.[49] Hence, the international breath research community is focusing on nanostructured chemi-resistive gas sensors for sensitive and selective detection of breath biomarkers. Herein, we will review SMO and 2DM nanocomposites in chemi-resistive gas sensing device configuration for the development of breathalyzers. Their corresponding sensing mechanisms and performance to various biomarkers was highlighted along with the social demands, challenges and regulatory aspects in the hope of directing future research towards non-invasive disease diagnosis through portable breathalyzers.

Chemi-resistors

Chemiresistors consists of a sensing film supported on an inert substrate where interdigitated or two metallic electrodes on their either side are deposited and a heater printed at the backside.[50] This gas sensor device configuration was explored in sensing various biomarkers including acetone, nitrous oxide, ammonia etc. and put to use for clinical trials.[51-53]Fig. 1 depicts a schematic of chemiresistor, fabricated by spin coating the graphene nanocomposite sensing film on alumina substrate with electrodes and heater printed on the either side. The sensor was explored for acetone sensing properties in presence of other interfering biomarkers along with humidity in exhaled breath and used in clinical trials.[54] The change in electrical properties of the sensors depends on the concentration of target biomarker. Various SMOs of different nanostructures have received a steady growth for their low cost fabrication process, reliable measuring electronics that demand very low power consumption.[55,56] Indeed, the non-invasive sensing devices for clinical applications must possess satisfactory portability and affordable cost in addition to their demonstrated sensor performances. Hence it has spurred the interest of the international breath research community to develop an economical hand-held chemi-sensor that is capable of monitoring biomarkers in exhaled breath. The nanomaterials based chemi-resistive sensors' parameters such as sensitivity, selectivity, repeatability, response and recovery time can be optimized by altering the characteristics of the sensing material and their definition were given as follows:
Fig. 1

Schematic illustration of chemiresistor gas sensing device configuration reproduced from ref. 54 with permission from Elsevier, Copyright 2021.

Relative response: ratio of resistance of the sensor in the ambient atmosphere to the resistance to the exposure of acetone of varying concentration.[57] Sensitivity: change in relative response with respect to the change in gas concentration.[57] Selectivity: measure of the relative response of other interfering biomarkers with respect to acetone. Repeatability: measure of variation in relative response for the same gas concentration under the same experimental conditions. Stability: measure of depreciation in sensor performance over a period of 1 month. Response and recovery time: time taken by the sensor to reach 90% resistance change of the final equilibrium value.[58] The basic sensing mechanism of these SMOs depends on the change in carrier concentration of the sensing material during gas interaction. This interaction may result in an increase or decrease in electrical resistance or conductivity.[59] n-type SMOs resistance decreases for reducing gas and increase for oxidizing gas from the baseline resistance. Meanwhile, a vice versa phenomenon occurs for p-type SMOs, where resistance decrease for oxidizing gases and increase for reducing gases.[59] Commonly, chemiresistors exhibit a change in its electrical resistance in the presence of specific target analyte it is engineered to, based on the following mechanisms.

Surface adsorbed oxygen ion mechanism

Conventional SMO gas sensors exhibit a change in its electrical resistance by the redox reaction between the atmospheric oxygen ions and target analyte adsorbed on the surface of the sensing film. In an operating temperature between 200–500 °C, the atmospheric oxygen are ionized to O−, O2− and O2− by gaining electrons from the conduction band of the sensing film leading to oxidation, causing changes in its electrical resistance termed as baseline (Fig. 2a). The vicinity of oxidizing/reducing target vapor near the sensing film reacts with the ionized oxygen causing increase/decrease in its electrical resistance.[60] For example, reducing carbon monoxide biomarker decreases the resistance from baseline (Fig. 2b) by contributing electrons as depicted in the equation,
Fig. 2

(a) Ionized oxygen ions adsorbed on the surface of the sensing film and (b) CO vapor interacts with ionized oxygen ions giving back electrons to SMOs.

In the presence of oxidizing NO2 biomarker, the resistance increases from the baseline as it gains electrons from the sensing film as depicted in the equation, The basic challenge in such mechanism involves operating at higher temperature for physisorption and chemisorption of atmospheric oxygen. Also, the ionized oxygen species depends on the operating temperature, an important criteria for stabilizing the baseline. The molecular species of oxygen are high compared to atomic species at temperatures less than 150 °C.[61] However, gas interaction occurs throughout the surface of the sensing material favorable for the transduction of whole concentration of target analyte at the vicinity of sensing material.[62,63]

Charge transfer mechanism

The gas sensing mechanism of 2D layered nanomaterial such as graphene, MoS2etc. differs from conventional SMO sensors by charge transfer process. The electrical resistance changes due to the adsorption, charge transfer and desorption of target analyte on the sensing film. The material acts as either donor or acceptor, depending on the nature of the target analyte, leading to a different transfer direction and quantities of charges. Once re-exposed to air, desorption of target analyte leads the resistance to its baseline.[64]Fig. 3 shows the charge transfer and density difference between n-type monolayer MoS2 with a donor (NH3) and acceptor (CO), where green region represents charge accumulation and red region shows charge depletion regions. The free electrons in the donor vapor (NH3) donates electron onto the MoS2 monolayer leading to an increase in charge carrier thus decrease in resistance. On the contrary, charge transfer from the conduction band of the n-type MoS2 to the acceptor vapor (CO) causes the charge density to decrease and increase in electrical resistance of n-type MoS2.[65] Unlike, the oxygen ion mechanism, physisorption dominates the adsorption of target analyte in two dimensional nanomaterials.[66] Physisorption being a weak force and un-directional, strong and selective binding of analyte is hindered and lead to sluggish recovery, respectively.
Fig. 3

Difference in charge density and transfer process of (a) NH3 and (b) CO on monolayer MoS2 reproduced from ref. 65 with permission from Springer, Copyright 2021. The blue and yellow balls represent Mo and S atoms. The red and green charge distribution corresponds to charge accumulation and depletion.

Band bending mechanism

Hybridization of SMOs with 2DMs creates heterojunction at the interface due the difference in their work function. Hence an obvious difference in Fermi energy levels causes an energy barrier height (ΔE) leading to accumulation and depletion region at the interface. The vicinity of target analyte near the heterojunction leads to the equalization of Fermi level due to band bending. Fig. 4 shows the energy band structure diagram of RGO/SnO2 before and after vapor infusion. Hybridization of SnO2 and RGO with a work function of 4.5 eV and 5.32 eV respectively causes a difference in Fermi energy levels (Fig. 6a). Further, infusion of donor vapor (acetone) leads to transfer of charge from lower work function (SnO2) to higher work function (RGO) tending to equalize the Fermi energy levels (Fig. 6b). This change in interfacial barrier causes a change in current flow characteristics across the rectifying heterojunction.[67] The hybridization elucidates peculiar properties due to the synergistic effect between SMO and 2DMs. The band bending favors electron accumulation and chemisorption of donor species. The variation in band bending generates a more pronounced resistance variation which improves the gas sensing performance.[68]
Fig. 4

Energy band diagram of RGO/SnO2 (a) before and (b) after gas infusion reproduced from ref. 67 with permission from American Chemical Society, Copyright 2021.

Fig. 6

(a) TEM images of SnO2 hollow nanotube and (b) its gas sensitivities to NO with concentration ranging between 9.7 ppm to 97 ppm at room temperature reproduced from ref. 97 with permission from Royal Society of Chemistry, Copyright 2021. (c) SEM images of different dimensions of SnO2 nanorod array, their electrical characteristics in the presence of air and 25 ppm various disease biomarkers of (d) 340 nm and (e) 40 nm SnO2 nanorod array adapted from ref. 91 with permission from American Chemical Society, Copyrights 2021. (f) Selectivity plot of SnO2 nanosheets towards alkenes reproduced from ref. 92 with permission from American Chemical Society, Copyrights 2021.

Important milestones had been achieved in the way of non-invasive diseases diagnosis through portable breath analyzers by the discussed sensing mechanisms. Peng et al.[69] had developed a device based on an array of chemiresistive nine functionalized gold nanoparticles to distinguish between healthy and lung cancer patients' breath. Recently, Blaikie et al.[70] had demonstrated a compact device for the estimation of acetone concentrations under fasting, exercise and normal conditions based on cavity enhanced spectroscopic technique. Sun et al.[71] had developed a transportable device to distinguish type-2 diabetic subjects from healthy subjects and validated with GC-MS with 600 breath samples. Gouma and team had demonstrated portable breath analyzers based on chemiresistive principle for various diseases (diabetes, renal diseases, lung diseases).[72-78] With the advancements of data acquisition instruments, the response to breath input from gas sensors can be digitized and transmitted to a computer for further signal preprocessing and feature extraction. Furthermore recent development of machine learning techniques provides better classification accuracy between healthy and diseased subjects. Hence, there is scope for improvement in each block represented in Fig. 5.
Fig. 5

Block diagrammatic representation of chemi-resistive nanosensors in breath analysis application.

Nanomaterials as chemi-resistive gas sensors for breath analysis

VOCs exhaled from human breath provide information about the fundamental cellular mechanism which when detected quantitatively and qualitatively favors early detection of disease limiting further complications. This way of disease diagnosis had its footprint from the ancient times associating fruity like breath odor with diabetes mellitus, fishy with liver complications and urine like breath odor with renal failure. After the advent of modern equipment, approximately 30 VOCs with elevated concentrations in breath have been associated with halitosis, diabetes mellitus, kidney malfunction, asthma and different cancers. Over the past decades considerable efforts have been focused on nanostructured materials for the detection of various VOCs with better sensing performances. Materials at nanoscale possess peculiar property compared to their bulk counterpart. Exploiting these properties by controlling their size and shape in the form of nanorods, nanowires, nanosphere improved the gas sensing performance. Moreover, their working conditions including the operating temperature were found to significantly improve the detection capabilities selective to breath biomarkers.[79] The motivation in the following section is to discuss these optimization strategies of promising nanomaterials as potential gas sensors incorporated in a breathalyzer for the detection of various disease biomarkers in exhaled breath.

Semiconducting metal oxide (SMO) nanostructures

Several different categories of material exhibit chemiresistive property. Among them, SMOs dominate as a superior gas sensing materials due to their capability to sense a wide variety of gases (oxidizing and reducing gases) and availability of numerous material choices.[80] Moreover, as they are simple in operation and demands low power, SMOs were largely applied in gas and solvent leak detectors in semiconductor industries, environmental monitoring, food processing, agricultural industry and medical diagnosis.[81] The first commercial SMO sensor at the beginning of 1970s used amorphous SnO2. Sensors made of SnO2 nanoparticles possess numerous advantages that include higher sensitivity, ability to operate at lower working temperature and thermally stable structure. This gas sensor was fabricated and patented by Taguchi which was later commercialized by Figaro Inc. The sensor was used for gas leak alarms in factories and residences to prevent fire accidents.[82] The demand for high performance gas sensors for various applications with low power consumption had diverted the research efforts towards SMOs as gas sensors. Moreover, these SMOs can be altered to deliver high sensing performance by varying the concentration of dopant incorporated, controllable morphology, methodology of sensing material preparation and tailoring physical/chemical properties.[83-86] However, sensitivity and selectivity being a primary sensing performance, various above mentioned optimization trials have been best possibly utilized. The intriguing property of SMOs that it appears in diverse shapes (nano spear, nanowires, nanobelts and nanotubes) favors more interaction sites for target biomarkers. Thus, leading to better sensing performances by optimizing their morphology and tailoring its physico-chemical properties. The permeable and porous structures of metal oxide are explored beneficial for the efficient gas diffusion and entire electron depletion accordingly. The high sensing performances of metal oxides are defined by low detection limits and short recovery times.[87,88] Numerous SMO nanostructures such as SnO2, WO3, In2O3, NiO, ZnO, CuO, Co3O4 has been utilized as standalone materials for the detection of various biomarkers.[89] Jiang et al., optimized 3 variations of the preparation procedure to synthesize SnO2 hollow nanotube observed from the TEM image shown in Fig. 6a. The detection capabilities of the prepared 1-dimensional hollow nanotube SnO2 were explored towards asthma biomarker (NO). The sensors were capable of sensing NO at room temperature in the concentration ranging between 9.7 ppb to 97 ppm well below breath NO concentration with a faster response time of 20 s for 9.7 ppb and 6 s for 9.7 ppm (Fig. 6b). These sensing performances of the SnO2 nanostructured chemi-resistive sensors were attributed to its novel morphology favorable for gas interaction sites and the exposure of dominant crystal facets (101).[90] The dependence of sensing performance on the morphology was further established by Xu et al., where they studied the acetone, isopropanol and ethanol sensing properties of SnO2 nanorods at room temperature. They found the difference in sensing pattern with respect to the length of the synthesized nanorods shown in Fig. 6c–e.[91] However, SnO2 nanosheets were found to be selective to ethane, propane and 1-butene compared to all other alkenes (Fig. 6f).[92] Similarly, WO3 nanofiber exhibited a response of 4, whereas nanowire showed a response of 2 to 1 ppm acetone.[93] These distinct sensing performances of the same nanomaterial with different morphology were ascribed to the modifications in grain boundaries, porous nature and surface area for interaction sites. Concurrently, the peculiar strategy of modulating the operating temperature for selectivity tuning towards a specific VOCs were studied. A SMO sensor operating at different temperature may behave like a distinct sensor with different performance to specific VOC.[94-96] SENSOR Lab at Bresica (Italy) has addressed the issue of selectivity tuning by modulating the operating temperature of ZnO nanoparticles. They found the sensor was selective to NO2 at 300 °C, H2 at 400 °C and CH4 at 500 °C and attributed to the thermodynamics of gas adsorption on the sensor surface including decomposition of gases on the surface.[97] This strategy was also exhibited on the commercial sensors from Figaro Inc.[98,99] Similarly, many other metal oxide nanostructure were utilized for sensing different biomarkers as listed in Table 2 by optimizing their morphology and operating temperature. The synergism between the optimization of morphology and operating temperature was explored in order to engineer the nanomaterial to selectively detect the biomarkers. Acetone was detected by ZnO nanomaterial with different morphologies such as flower shaped, brittle glass shaped and dandelion like spheres operated at 300 °C, 215 °C and 230 °C.[100,101,103] Yet, ZnO nanosheets showed high sensitivity to formaldehyde and acetaldehyde with a lower detection limit of 50 ppb working at 220 °C.[102] Likewise, In2O3 nanowires detected acetone at 400 °C, whereas thick wires detected low concentration (500 ppb) of NO2 at temperature less than 300 °C.[110] Yet, In2O3 nanobricks detected 500 ppb of NO2 at a significantly lower operating temperature of 50 °C.[112] These discussions illustrated the capability of tuning the selectivity by various optimization strategies. However, the response to exhaled concentration range tend to be poor due to lack in enhanced surface area for analyte interaction. In addition, meager conductivity of SMOs hinders the reproduction of the electrical change before and after analyte interaction to the outer world.

The gas sensing performances of various SMOs with morphological optimization towards different diseases biomarkers in exhaled breath

MaterialsNanostructureGasDisease biomarkerConcentrationSensor responseRef.
ZnO3D hierarchical flowerC3H6ODiabetes100 ppm18.6 100
ZnOBrittle grassC3H6ODiabetes100 ppm107 101
ZnONanosheetsFormaldehydeLung cancer1 ppm75% 102
Acetaldehyde77%
ZnODandelion like spheresC3H6ODiabetes100 ppm33 103
SnO2NanotubesNOxAsthma9.7 ppb16.1 90
SnO2Thin filmsNH3Renal failure50 ppm6.94 104
SnO2MicrocubesTolueneLung cancer1 ppm2.4 105
Benzene1.5
SnO2Flower-like nanostructuresTolueneLung cancer100 ppm9.7 106
Formaldehyde9.5
WO3NanocolumnsC3H8O100 ppm3 107
WO3NanoplateNO2Asthma5 ppm10 108
WO3NanowireNH3Renal failure300 ppm2.39 109
In2O3NanowiresC3H6ODiabetes25 ppm 110
In2O3NanocrystalsNOxAsthma970 ppb1.9 111
In2O3NanobricksNO2Asthma500 ppb402 112
Co3O4NanocubeC3H6ODiabetes500 ppm4.88 113
Nanosphere1.62
Co3O4NanosheetC3H6ODiabetes100 ppm6.1 114
Nanofiber4.0
Nanorod2.7

2D nanomaterials

On the other hand, 2DMs has intriguing properties such as high surface area, high conductivity and high carrier mobility at room temperature with low noise that facilitates better response for target analytes. Exploiting these merits, graphene and its derivatives were the most explored carbon materials for gas sensor application in the past decade. The transparent and flexible characteristics of graphene were utilized for different configuration gas sensing devices.[115-118] The defects induced by surface functionalization may influence the gas adsorption and desorption by the increase in number of reactive sites causing high sensitivity. Numerous review articles on graphene based gas sensors with a special focuses on its application in different fields, transduction principles, functionalization with metals and polymers were presented.[119-126] Inspired by the physic-chemical and electrical properties of graphene derivatives favorable for gas sensing applications, researchers are exploring over the periodic table for the search of ultrathin 2DMs. Among them, 2DMs represented by MX2, where M denotes the transition metals like Mo, W, Hf, Ti, Zr, V, Nb, Ta, Re, etc. and X denotes the chalcogens (Te, S or Se).[127] However, only certain transition metal disulfides (TMDs) such as MoS2, WS2 and SnS2 have been utilized as a sensing film for the detection of various disease biomarkers in exhaled breath as listed in Table 3. In comparison with graphene (zero band gap), TMDs possess tunable bandgap (1–2 eV) with a shift from indirect to direct bandgap as a function of layer thickness due to exfoliation.[136] Among other chalcogens, TMDs are widely explored due to its abundant presence in nature, less toxic and stable in atmosphere compared to metal selenides and metal tellurides. Their gas sensing performances were illustrated in Fig. 7. The NO2 sensing performance of atomic layered MoS2 nanosheet at low concentration of 120 ppb have not shown a complete recovery to the baseline and same occurrence was observed for subsequent concentrations (Fig. 7a).[128] Identically, monolayer graphene exhibited no recovery to the baseline at 12 ppm triethylamine (TEA) as shown in Fig. 7b.[129] Similar performance was witnessed by SnS2 nanosheets with a high response (∼170 s) and recovery time (∼140 s) to 10 ppm NO2 (Fig. 7c).[66] This is attributed to their layered structure possessing weak van der Waals interlayer force favorable for exfoliation down to single and multilayers. However, their strong molecular interlayer force causes restacking of the layer.[137] It is therefore desirable to composite them with a nanomaterial that acts as spacers which avoids restacking issues and facilitates porous structure for gas adsorption driven by high surface area, absorption coefficient and fast electron transfer.[138]

The gas sensing performances of TMDs towards different diseases biomarkers in exhaled breath

MaterialsLayer thicknessGasDisease biomarkerConcentrationSensor responseRef.
MoS2AtomicNO2Asthma120 ppb35% 128
1TEA1 ppm3% 129
AtomicNH3Renal failure5 ppm1% 130
2NOAsthma2 ppm80% 131
WS25 nmNO2Asthma5 ppm68.4% 132
110 nmNH3Renal failure5 ppm1.6% 133
Thin filmNH3Renal failure5 ppm0.2% 134
SnS21–3NH3Renal failure100 ppm2.13 135
NO2Asthma10 ppm36.33% 66
Fig. 7

(a) Transient response of atomic-layered MoS2 to NO2 with concentration ranging from 120 ppb to 1000 ppb operated at room temperature reproduced from ref. 128 with permission from American Chemical Society, Copyrights 2021 (b) conductivity change of monolayer graphene upon exposure to 12 ppm TEA at room temperature reproduced from 129 with permission from American Chemical Society, Copyrights 2021 and (c) response/recovery of SnS2 to 10 ppm NO2 operated at 120 °C adopted from ref. 66 with permission from American Chemical Society, Copyrights 2021.

SMOs/2DM nanocomposites

The alternate approach of SMO/2DM binary nanocomposite may solve several challenges faced by standalone SMO or 2DM in enhancing the sensor performances in all the aspects. Their complementing features suitable for gas sensing applications are listed in Table 4. The synergism favors electronic, chemical and geometrical effects of the sensing material. The combination of SMOs and 2DMs may rectify the restacking problems of the multilayer 2D sheets and facilitates porous structure for enhanced gas diffusion. Further, the depletion layer formed at the interface of n–n, p–n or p–p heterojunction modulates due to gas diffusion and may enhance charge transport along with the favorable chemical bonds formed between SMO and 2DM.[139]

Complementing features of SMOs and TMDs

AdvantagesDisadvantages
SMOsScalable fabricationSlow carrier transfer
Low costHigh operating temperature
Long-term stabilityLower gas response
TMDsFast carrier transferSluggish recovery
Low operating temperatureLow selectivity
High gas responseLack of stability
As discussed in the previous section, SnO2 was widely used as a standalone material for gas sensors owing to its wide bandgap (3.6 eV). Moreover, its enhanced optical, electrical and electrochemical properties were suitable in various gas sensing device configurations. However, its capability of selectively detecting gas concentration as low as in parts per billion among diverse environment was hindered for real time breath analysis application. Hence, numerous efforts have been made to composite it with 2DMs for the detection of variety of breath biomarkers under varying structural morphology of the nanocomposite and working conditions of the sensor.[140] Graphene–SnO2 nanocomposite showed selective sensing to NO2 at 150 °C achieving a lower detection limit of 1 ppm with a response of 24.7 (Fig. 8a).[141] Meanwhile, Zhang et al. has showed that graphene–SnO2 nanocomposite was also selective for H2S operated at 260 °C with a detection limit of 1 ppm (Fig. 8b).[142] Further, SnO2 with various graphene derivatives was found to exhibit superior sensing performances detailed in our previous review.[143] Besides, composition of SnO2 with TMDs may elucidate peculiar properties due to synergism between them. The most widely used MoS2/SnO2 p–n heterojunction among other TMDs, demonstrated better sensing performances to TEA at an operating temperature of 230 °C (Fig. 8c). The performance of Mo/Sn ratio of 0.53 dominated other mole ratios of the composite. The sensor showed a response of 24.9 for 100 ppm of TEA with a detection limit of 5 ppm.[144] Meanwhile Han et al., investigated the detection of NO2 at room temperature by varying the Mo/Sn molar ratio. The study revealed that 1.25 mL of stannic chloride with 20 mL MoS2 nanosheet dispersion (MS-1.25) showed highest response of 18.7 to 5 ppm NO2. Moreover the response time, complete recovery, long term stability and selectivity of the composite was significantly improved. The authors speculated the enlargement of surface area by the incorporation of SnO2 on MoS2 nanosheets and the p–n heterojunction changed the electronic properties locally.[145] The humidity sensing property of WS2/SnO2 revealed the importance of 2DM/SMO composites, where a significant improvement in sensing performances (862.8 times) were observed compared to standalone SMO or 2DM.[146] Moreover, with much electronegative in nature, SnS2 was made composite with SnO2 to improve the selectivity towards ammonia and NO2.[147] The study by Li et al. showed significant selectivity to ammonia with a response of 2.48 for 100 ppm at room temperature among other breath biomarkers (Fig. 8d). The sensor exhibited linear response at exhaled breath concentration range.[147] However, Ou et al., has established a strong detection of NO2 by SnS2 at lower operating temperature of 160 °C compared to other VOCs (Fig. 8e) and capable of detecting as low concentration as 0.6 ppm. They found the high selectivity of NO2 at 160 °C due to the lower adsorption energy of NO2 to SnS2 as shown in Fig. 8f.[66]
Fig. 8

Selectivity of (a) graphene–SnO2 binary nanocomposite to 3 ppm NO2 at 150 °C reproduced from ref. 141 with permission from American Chemical Society, Copyrights 2021 and (b) graphene–SnO2 binary nanocomposite to 50 ppm H2S at 260 °C adapted from ref. 142 with permission from Royal Society of Chemistry, Copyrights 2021. (c) Response of different Mo/Sn molar concentration of MoS2/SnO2 sensor to varying concentration (5–100 ppm) of TEA at an operating temperature of 280 °C used from ref. 144 with permission from American Chemical Society, Copyrights 2021. (d) Selectivity characteristics of SnO2/SnS2 nanocomposite sensor to 500 ppm of ammonia and various gases at room temperature adapted from ref. 147 with permission from Royal Society of Chemistry, Copyrights 2021. (e) Response of SnS2 sensor to various biomarkers at 160 °C, (f) surface adsorption energy of SnS2 with studied biomarkers adapted from ref. 66 with permission from American Chemical Society, Copyrights 2021.

Similarly, many other combinations of SMO/2DM were exploited for the detection of various exhaled biomarkers listed in Table 5 by various optimization strategies. Yan et al., has investigated the sensing performance of ZnO coated MoS2 to ethanol concentration ranging between 50–1000 ppm at an operating temperature of 260 °C. Their results suggested the remarkable sensing behavior of ZnO@MoS2 binary metal oxide nanocomposite compared to pure ZnO in terms of sensitivity and selectivity to ethanol (Fig. 9a and b). These results are attributed to the development of interface at the heterojunction leading to rapid electron transfer by the direct conduction paths provided by MoS2.[157] Following this finding, Zhao et al., optimized the layer thickness of MoS2 on ZnO nanowires by varying the sputtering time to investigate NO2 sensing behavior at 200 °C. The sensor exhibited excellent sensitivity with a detection limit of 200 ppb favorable for breath analysis (Fig. 9c). Furthermore the sensor showed good selectivity to 50 ppm of NO2 in comparison with the same concentration of NH3, CO2 and CO along with stable recovery and repeatability (Fig. 9d).[156] Meanwhile, Qin et al. has hybridized TiO2 with WS2 with different molar ratio (0.44 to 1.65) to improve the selectivity of WS2 2DM towards ammonia at room temperature. The composite with a molar ratio of 0.44 TiO2 QD/WS2 exhibited fast response and high selectivity to 500 ppm ammonia.[163] Furthermore, tungsten was also used in combination with WS2 to detect ammonia, H2 and NO2. They optimized the working temperature at 150 °C and achieved a lower detection limit of 1 ppm to ammonia.[168] These discussions provide a notion that different combination of SMO/2DMs with varying optimization strategies such as morphology, nanosheet's layer thickness and operating temperature would tune the sensing system towards specific biomarker with enhanced sensitivity. Similarly many other binary and ternary nanocomposites with 2DMs can be explored for elucidating the peculiar properties and explore them for the detection of various breath biomarkers. Incorporation of these sensors in handheld portable breath analyzer may possibly favor the underprivileged community in the poor healthcare resource setting. The biomarker concentration displayed on the system or rather transmitted wirelessly could pave way for universal use, for its effortless sample collection procedures. In the future, SMO/2DM based nanosensors could be miniaturized on a single lab-on-chip and could be used as a pocket device or an add-on to the mobile phones.

The gas sensing performances of various SMO/TMD nanocomposites towards different diseases biomarkers in exhaled breath

SMO2DMGasDiseaseConcentrationResponseRef.
SnO2GrapheneNO2Asthma5 ppm72.6 (Rg/Ra) 141
H2SHalitosis50 ppm130 (Ra/Rg) 142
Reduced graphene oxideNH3Renal failure1000 ppm 148
HCHOLung cancer10 ppm435 149
MoS2TEA100 ppm24.9 (Ra/Rg) 144
NO2Asthma5 ppm18.7 (Gg/Ga) 145
CH4100 ppm2.014 150
NH3Renal failure50 ppm10% 151
WS2Humidity95% RH8.5 (Ra/Rg) 152
SnS2NH3Renal failure100 ppm2.48 (Ig/Ia) 147
NO2Asthma10 ppm36.33 66
ZnOReduced graphene oxideNO2Asthma0.5 ppm12 (Rg/Ra) 153
MoS2C3H6ODiabetes5 ppm14.40 (Ra/Rg) 154
NH3Renal failure100 ppm61.92% 155
NO2Asthma50 ppm31.2% 156
C2H5OHAlcohol consumption50 ppm42.8 (Ra/Rg) 157
WO3GrapheneH2SHalitosis5 ppm65.5 (Ra/Rg) 158
C3H6ODiabetes5 ppm13.7 (Ra/Rg)
NO2Asthma5 ppm133 (Rg/Ra) 159
MoS2H2SHalitosis25 ppm20% 160
TiO2Reduced graphene oxideMethanol800 ppm96.3% 161
MoS2C2H5OHAlcohol consumption100 ppm14.2 162
WS2NH3Renal failure500 ppm56.69 163
Fe2O3Reduced graphene oxideH2SHalitosis1 ppm9.2 164
Co3O4Graphene oxideC3H6ODiabetes52.29 (Rg/Ra) 165
MoS2NH3Renal failure0.110.3% 166
Cu2OGrapheneH2SHalitosis100 ppb36% 167
Fig. 9

(a) Typical response of ZnO@MoS2 to ethanol at concentration ranging between 50 ppm to 1000 ppm operated at 260 °C, (b) selectivity characteristics of ZnO@MoS2 to 100 ppm ethanol at an operating temperature of 260 °C adopted from ref. 157 with permission from Elsevier, Copyrights 2021, (c) response of different sputtering time MoS2 on ZnO nanowires to varying concentrations of NO2 at 200 °C and (d) selectivity characteristics of MoS2/ZnO to 50 ppm NO2 at an operating temperature of 260 °C reproduced from ref. 156 with permission from Elsevier, Copyrights 2021.

Socio-economic demands and companies

Nanosensors based on chemi-resistive principle for breath analysis has seen progress in recent years in terms of sensitive and selective detection of specific breath biomarkers amidst various interference including exogenous gases and humidity in breath.[169-171] Meanwhile with low power demand resulting in the reduction of device dimension on a single lab-on-chip, nanosensors are the choice of technology for incorporation in portable breathalyzers for disease diagnosis. Also, an array of cross-reactive nanosensors incorporated in the breathalyzer would mimic the mammalian olfactory and detect various gases emanating from breath probing the metabolic processes at the fundamental cellular levels favoring early detection of diseases. Accurate detection of these trace level gases would pave way for non-invasive, user friendly, personalized home care diagnostic equipment which lead to better control of diseases and monitor the effect of medication. Moreover, the instant display of results may avoid pre-analytical and post-analytical processes such as sample collection, preparation and test report dispatch. Also it enables mass screening during pandemic leading to reduced transmission rate of the disease.[172] These processes eliminate consumables thus considerably reduce the global health expenditure. The merits of nanosensors create a demand for breathalyzers in global market demanding a socio-economic balance. Hence researchers across the globe are having high hopes and making strides on startups for disease diagnosis through breath analysis by various technologies. For instance, SpiroNose® developed by Breathomix utilizes 7 different SMO sensors that capture real-time breath profiles. The between-days repeatability of asthmatic and healthy subjects was precise and was even better when compared to the routine standard test (spirometry).[173] Moreover, it satisfactorily discriminated healthy subjects and patients with COPD, asthma and lung cancer.[174] Similarly, Aeonose® developed by The Enose Company, Netherlands have been found suitable for the prescreening of prostate, lung and collateral cancer proving it suitability for personalized home care.[175-179] Also, AmBeR® was designed and developed by BreathDX consists of an array of sensors fabricated by inkjet printing functional nanomaterials capable of ammonia measurement in ppb concentration range.[180,181] Each of the startup listed in Table 6 is focused on identifying various disease by fabricating a sensor selective to specific biomarkers and using other analytical technologies.

List of startups across the globe focusing on various disease diagnoses through breath analysis involving different technologies

Sl. no.CompanyCountryInceptionFocusProduct & technology
1BreathomixNetherlandsJune 2018Cancer, inflammatory and infectious diseasesSpiroNose® – 7 different MOS sensors
2The Enose CompanyNetherlands2013Oncology, infectious-, and neurological diseases, colon cancer, lung cancer and tuberculosisAeonose® – metal oxide semiconductors
3Owlstone MedicalUK2005Liver disease, colon cancer and lung cancerField Asymmetric Ion Mobility Spectrometry (FAIMS)®
4Breath Diagnostics Inc.US2014Lung cancerOneBreath® – mass spectrometry
5BreathDXUKAmmonia quantificationAmBeR® – nanosensors
6CAIRE Diagnostics formerly Spirosure Inc.US2012Allergic airway inflammation, asthma and other pulmonary conditionsFenom Pro® – electrochemical
7Breath Analyzers Pte. Ltd.Singapore2016Gastrointestinal diseases, helicobacteriosisHepyScreen®
8Algernon Pharmaceuticals formerly Breathtec Biomedical Inc.Canada2015Liver disease – Non-Alcoholic Steato Hepatitis (NASH), chronic kidney disease and inflammatory bowel disease
9New England Breath TechnologiesUK2018Type 2 diabeticsGlucair®
10Deep Breath InitiativesSwitzerland2018Therapeutic drug monitoringMass spectrometry

Challenges and regulatory aspects

Even though with the high socio-economic demand, inception of startups, research and development across the globe with the state-of-the-art technologies, there are numerous challenges needs to be addressed. For the commercial deployment of breathalyzer for non-invasive disease diagnosis in clinical setup and for personalized homecare utilization, much care must be provided in designing a nanomaterial based chemi-resistive sensor. Sensors should possess accurate detection capabilities as the breath sample is highly complex and informative due to the changes in breath volatolomics that occurs on the fundamental cellular processes. Moreover, the biomarker is in parts per million which demands the sensor to possess high sensitivity and selective to detect the trace level amount among other interfering biomarkers along with the strong influence of relative humidity in exhaled breath. Thus the sensor incorporated in breathalyzer should possess superior gas sensing performances such as sensitivity and selectivity towards specific disease biomarkers, humidity-resistive property, faster response and recovery time etc. However, desiccants and pre-concentrators are crucially important, if the sensors do not satisfy the humidity-resistive property and selectivity, respectively.[182] Moreover, as only the alveolar breath contains information about the cellular processes, the sensor chamber should be designed in such a way to accommodate the whole of alveolar breath and avoid sharp edges to eliminate recirculation zones. There is still no standardization on the collection of sample from either oral or nasal cavity. Hence, influence of exogenous production and presence of the biomarker as a pollutant in the atmosphere may hinder the exact quantification of endogenous production of biomarker. More importantly, the biomarkers associated with specific diseases by the analytical techniques such as GC-MS is questionable as the pathophysiology of a single disease may diffuse numerous VOCs. Therefore, a global library of VOCs with corresponding diseases needs establishment to develop a cloud of breath database which may act as a reference standard. Further, the measuring electronics requires proper optimization to avoid instrumentation errors after proper breath sample collection and sensor design. The lack of standardization of library of VOCs, breath sample collection procedure, chamber design, sensor positioning and measuring electronics causes an insignificant criterion for reproducibility of the diagnostic outcomes.[183,184] The mentioned issues in standardization lead to huge variations in results between different studies and are hard to replicate.[185] Further, the sensors work in harsh environment (humidity and temperature) leading to eventual degradation in sensor performance. Hence, as there are opportunities and demand for a breathalyzer, corresponding challenges and improvements are necessary. The use of nanomaterials for medical devices and implant materials has been successfully explored. Particularly in USA and Taiwan, nanomaterial incorporated products were widely seen that exhibits better performance compared to their bulk counterpart. However, safety and security being a primary concern, the considerable change in properties of the nanomaterial used in a medical device requires detailed study on their adverse effects on human body including toxicity. The dimensions of the nanoparticle decide its hazardous nature. Smaller particles may enter the human body through respiratory tract during inhalation, skin or oral ingestion due to the poor immune system of human body towards nanoparticle. For instance, nanoparticles less than 30 nm in size may damage the central nervous system, the defective mechanism of lung cells is not capable of handling nanoparticle with the size lesser than 70 nm and nanoparticle size less than 50 nm may enter the nucleus of human cells.[186,187] Hence, nanomaterial based medical devices have raised the concern for health authorities to develop certain regulatory aspects for safety assessment that does not develop any temporary or permanent discomfort to the users. The risks associated with the absorption or distribution of nanomaterial in human body must be established. Along with these safety assessments, no compromise in the quality must be ensured by the manufacturer by focusing on repeated validation on the manufactured nano medical device.[188] Hence, regulatory requirements are good manufacturing procedures, labeling and warning, approval procedures and post market follow up.

Conclusion and future outlooks

Non-invasive disease diagnosis through breath analysis is one of the foreseen healthcare services. Their tendency to replicate the fundamental cellular process makes it more attractive for early diagnosis leading to the increases in survival by adopting effective treatment methodologies. To this direction, chemi-resistive VOC sensors with a well understood sensing mechanisms for simple, fast and accurate detection of breath biomarkers were presented in this current review. These chemi-resistive gas sensors possess miniaturization capabilities with no trade-off on the performance, which pose as a primary requirement for point-of-care medical devices. As mentioned in this review, numerous SMO nanostructures, 2D nanosheets and their composites have been utilized for the detection of various disease biomarkers. Their demonstrated performances were favorable for diagnosis of disease from exhaled breath with an easy sampling procedure and instant display of the outcome. Besides, their mass-screening competency during COVID-19 pandemic has found a new market for portable breathalyzers. Whilst, the strength of the technology remains weak and inconclusive. This reflects the lack of standardization of breath sampling, sensor technologies and sample sizes across the spectrum of studies. Under-powering alongside difficulties including inference by numerous other external sources of VOCs and complexity of breath have both contributed to the setback of the technology for regular clinical trial. It seems that the implementation of gas sensors for breath analysis application has not reached the maturity for the widespread acceptance and usage. Nonetheless, SMO/2DM nanocomposites are amongst the few materials that enhance geometrical, chemical and electronic properties for gas sensing applications to tune its selective binding with a single biomarker at lower concentration. Further, placement of cross reactive sensors and coupling of breath sample to sensors through pre-concentrator devices on a single lab-on-chip may realize the dream of non-invasive disease diagnosis through breath analysis. However, with the rapid advancements in the field of nanotechnology, regulatory aspect of these medical devices essentially takes care of all the relevant issues. The quality and safety of these devices must be enforced by the regulatory authorities in order to protect the manufacturing staffs and the end-users. Meanwhile, frequent updates are necessary with respect to the emerging applicability of nanomaterials and devices.

Conflicts of interest

The authors declare no conflict of interest, financial or otherwise.
  87 in total

1.  Highly sensitive nitric oxide gas sensor based on ZnO-nanorods vertical resistor operated at room temperature.

Authors:  Pragya Singh; Li-Lun Hu; Hsiao-Wen Zan; Tseung-Yuen Tseng
Journal:  Nanotechnology       Date:  2018-12-11       Impact factor: 3.874

2.  A roadmap for graphene.

Authors:  K S Novoselov; V I Fal'ko; L Colombo; P R Gellert; M G Schwab; K Kim
Journal:  Nature       Date:  2012-10-11       Impact factor: 49.962

Review 3.  Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements.

Authors:  Zhennan Wang; Chuji Wang
Journal:  J Breath Res       Date:  2013-08-20       Impact factor: 3.262

Review 4.  The clinical potential of exhaled breath analysis for diabetes mellitus.

Authors:  Timothy Do Chau Minh; Donald Ray Blake; Pietro Renato Galassetti
Journal:  Diabetes Res Clin Pract       Date:  2012-03-10       Impact factor: 5.602

5.  Bifunctional sensing characteristics of chemical vapor deposition synthesized atomic-layered MoS2.

Authors:  Byungjin Cho; Ah Ra Kim; Youngjin Park; Jongwon Yoon; Young-Joo Lee; Sangchul Lee; Tae Jin Yoo; Chang Goo Kang; Byoung Hun Lee; Heung Cho Ko; Dong-Ho Kim; Myung Gwan Hahm
Journal:  ACS Appl Mater Interfaces       Date:  2015-01-21       Impact factor: 9.229

Review 6.  Breath analysis of cancer in the present and the future.

Authors:  Reef Einoch Amor; Morad K Nakhleh; Orna Barash; Hossam Haick
Journal:  Eur Respir Rev       Date:  2019-06-26

Review 7.  Nanostructured Chemiresistive Gas Sensors for Medical Applications.

Authors:  Noushin Nasiri; Christian Clarke
Journal:  Sensors (Basel)       Date:  2019-01-23       Impact factor: 3.576

8.  Piezoresistive Response of Quasi-One-Dimensional ZnO Nanowires Using an in Situ Electromechanical Device.

Authors:  Sören Kaps; Sanjit Bhowmick; Jorit Gröttrup; Viktor Hrkac; Douglas Stauffer; Hua Guo; Oden L Warren; Jost Adam; Lorenz Kienle; Andrew M Minor; Rainer Adelung; Yogendra Kumar Mishra
Journal:  ACS Omega       Date:  2017-06-28

9.  Exhaled human breath analysis in active pulmonary tuberculosis diagnostics by comprehensive gas chromatography-mass spectrometry and chemometric techniques.

Authors:  Marco Beccaria; Carly Bobak; Boitumelo Maitshotlo; Theodore R Mellors; Giorgia Purcaro; Flavio A Franchina; Christiaan A Rees; Mavra Nasir; Wendy S Stevens; Lesley E Scott; Andrew Black; Jane E Hill
Journal:  J Breath Res       Date:  2018-11-05       Impact factor: 3.262

View more