Anil Kumar Pandey1, Akshima Sharma2, Sunil Kumar1, Ashish Negi1, Satnam Singh1, Sanjay Kumar2, Rakesh Kumar1.
Abstract
Objective: The aim of the present study was to design and evaluate two MeVisLab networks, one for co-registration of positron emission tomography/computed tomography (PET/CT) images and second for cropping the co-registered PET/CT images. Materials andEntities:
Keywords: Image co-registration; MeVisLab; positron emission tomography/computed tomography
Year: 2022 PMID: 35478680 PMCID: PMC9037870 DOI: 10.4103/ijnm.ijnm_107_21
Source DB: PubMed Journal: Indian J Nucl Med ISSN: 0974-0244
Figure 1Network designed for co-registration of positron emission tomography and computed tomography images (a) Showing the highlighted DirectDicomImport module, which provides option to browse and load computed tomography and positron emission tomography DICOM files, (b) Window opens up after selecting DirectDicomImport module in which one can select computed tomography DICOM study and positron emission tomography DICOM study to import one by one, (c) After importing computed tomography and positron emission tomography studies the co-registered images can be viewed using ViewRegistrationResults module, (d) Window opens up after selecting ViewRegistrationResults module to review the co-registered images. Selecting SaveImage module will save co-registered computed tomography and positron emission tomography studies in DICOM format
Figure 2Network designed for cropping of co-registered positron emission tomography and computed tomography images (a) LocalImage and LocalImage1 provides option to browse and load saved co-registered positron emission tomography and computed tomography studies, (b) Selecting Subimage modules opens up the window in which user will have to click on Full Size option and then can specify the range of X-, Y-and Z-axis, (c) Showing the co-registered computed tomography and positron emission tomography images opened up on selecting SynchroView2D on which user can decide range of X-, Y-and Z-axis
MERIT parameters for positron emission tomography and computed tomography image registration
| Parameters | Value |
|---|---|
| Component settings | |
| Transformation* | |
| Type | Affine |
| Dimensions | 2-D |
| Similarity | |
| Type | Normalized mutual information |
| NMI bins | 32 |
| Interpolation* | |
| Internal | Nearest neighbor |
| Output | Nearest neighbor |
| Plugin* | |
| Registration type | Linear |
| Settings* | |
| Multi resolution | |
| Number of levels | 1 |
| Stop level | 0 |
| Scale factor | 0.63 |
| Accelerations | |
| Open MP threads | 2 |
| Initialization | |
| Mode | Image center equalization |
| Optimizer settings* | |
| Affine-linear optimizer | |
| Optimizer | Newton |
| Finite difference* | |
| Translation | 1 |
| Rotation | 0.01 |
| Scale | 0.01 |
| Shear | 0.01 |
| Stop criteria* | |
| Termination tau | 1×10−05 |
| Maximum runtime (s) | −1 |
| Iterations* | |
| Minimum per level | 2 |
| Maximum overall | 200 |
| Last level minimum | 1 |
| Last level maximum | 5 |
| Stepsize control* | |
| Step size control mode | Armijo |
| Start step size | 1 |
| Minimal step size | 1×10−07 |
| Reduction factor | 0.5 |
| Decrease | 0.001 |
*Default parameters incorporated in MERIT. NMI: Normalised Mutual Information, MP: Multiple Processor
Figure 3Co-registered positron emission tomography/computed tomography images (a and b) are images co-registered with our network, (c and d) are images co-registered using Seimens workstation, (e and f) are images co-registered using GE workstation
Figure 4(a) Is showing the result of MeVisLab network developed for cropping in positron emission tomography/computed tomography DICOM images of prostate cancer. With this MeVisLab network cropped images can be saved in DICOM format; (b and c) Are showing the cropped images of Seimens workstation and GE workstation, respectively. The facility of copping of images in DICOM format is not available on Seimens and GE workstations. Co-registered images were saved in JPEG format from Siemens and GE workstation and have been cropped and displayed so that effective visual comparison can be made