Literature DB >> 3546627

Chemical breakdown of technetium-99m DTPA during nebulization.

D L Waldman, D A Weber, G Oberdörster, S R Drago, M J Utell, R W Hyde, P E Morrow.   

Abstract

Aerosols of 99mTc diethylenetriaminepentaacetic acid ([99mTc]DTPA) used for measuring lung permeability and lung ventilation require a radioaerosol delivery system to produce an aerosol with reproducible size and radiochemical purity. To test how well nebulizers meet this requirement, radiochemical purity of aerosols produced with a jet and an ultrasonic nebulizer was evaluated. The activity median aerodynamic diameter (AMAD) and geometric standard deviation (sigma g) of radioaerosols were 0.46 micron (sigma g = 1.6) for the jet nebulizer and 0.70 micron (sigma g = 1.7) for the ultrasonic nebulizer. Paper and liquid chromatographic assays were obtained on the [99mTc]DTPA aerosol solute produced with each nebulizer. The results of these tests showed major differences in radiochemical purity. Aerosols produced in the jet nebulizer consistently showed greater than 90% of the radioactivity bound to the DTPA ligand whereas aerosols produced in the ultrasonic nebulizer showed less than 10% of the radioactivity bound to DTPA. The results support the need to test radiochemical purity of aerosols before using an aerosol nebulizer for pulmonary imaging and clearance studies.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3546627

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  4 in total

Review 1.  The use of radionuclide techniques in the assessment of alveolar-capillary membrane permeability on the intensive care unit.

Authors:  D N Hunter; C J Morgan; T W Evans
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

Review 2.  The science of nebulised drug delivery.

Authors:  C O'Callaghan; P W Barry
Journal:  Thorax       Date:  1997-04       Impact factor: 9.139

3.  The stability of 99mTc-DTPA and 99mTc-HIDA following ultrasonic nebulisation.

Authors:  N Durovic; M Pillay; P H Cox
Journal:  Eur J Nucl Med       Date:  1988

4.  Influence of hilar deposition in the evaluation of the alveolar epithelial permeability on 99mTc-DTPA aerosol inhaled scintigraphy.

Authors:  Shigeyuki Ogi; Eisuke Gotoh; Mayuki Uchiyama; Kunihiko Fukuda; Mitsuyoshi Urashima; Nobuyoshi Fukumitsu
Journal:  Jpn J Radiol       Date:  2009-02-08       Impact factor: 2.374

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.