| Literature DB >> 35465250 |
Fang Wang1, Qing Zhan1, Shi-Ping Yu2, Hai-Ting Feng1, Ping Hu2, Zi-Feng Zhong1, Ting-Ting Qu1,3.
Abstract
Purpose: Parvovirus B19 (B19V) infection is a viral threat after kidney transplantation. It is mainly transmitted by close-contact inhalation of aerosolized viral particles. The risk of nosocomial spread of B19V in the transplantation ward is quite high. This study aimed to evaluate the quality of routine disinfection and the effectiveness of isolation measures in the wards of B19V-infected kidney transplant recipients. Patients andEntities:
Keywords: B19V; disinfection; isolation; kidney transplantation ward; parvovirus B19
Year: 2022 PMID: 35465250 PMCID: PMC9030386 DOI: 10.2147/IDR.S356174
Source DB: PubMed Journal: Infect Drug Resist ISSN: 1178-6973 Impact factor: 4.177
Figure 1The floor plan of the kidney transplantation ward.
B19V RT-PCRa Results of Respiratory Tract Samples from Patients and Healthcare Workers
| Source of Respiratory Tract Samples | B19V +b/Totalc | Resultsd |
|---|---|---|
| B19V-confirmed patients in isolation wards | 2/4 | 7.4*104, 1.4*105 |
| Patients in general wards | 0/15 | / |
| Doctors in charge | 0/2 | / |
| Primary nurse | 0/1 | / |
Abbreviations: aRT-PCR, reverse transcription polymerase chain reaction; bB19V+, number of positive samples; cTotal, total number of samples; dRT-PCR, results (copy number/mL).
B19V RT-PCRa Results of Environmental Surface Samples Before Disinfection
| Areas | Sampling Sites | B19V +b/Totalc | Resultsd |
|---|---|---|---|
| B19V isolation wards | Bedside tables | 2/2 | 4.5*103, 1.0*104 |
| Bed rails | 2/2 | 1.0*104, 1.8*103 | |
| Toilet washbasins | 1/1 | 1.4*103 | |
| Flush button of the toilet bowl | 0/1 | ||
| Return air outlet surface of the air purification device | 3/3 | 3.2*103, 3.5*103, 2.7*103 | |
| General wards | Bedside tables | 0/1 | / |
| Bed rails | 0/1 | / | |
| Toilet washbasins | 0/1 | / | |
| Flush button of the toilet bowl | 0/1 | / | |
| Return air outlet surface of the air purification device | 0/3 | / |
Abbreviations: aRT-PCR, reverse transcription polymerase chain reaction; bB19V+, number of positive samples; cTotal, total number of samples; dRT-PCR, results (copy number/mL).
B19V RT-PCRa Results of Environmental Surface Samples After Disinfection
| Areas | Sampling Sites | 3 h Later | 5 h Later | 14 h Later | Resultsd |
|---|---|---|---|---|---|
| B19V +b/Totalc | |||||
| B19V isolation wards | Bedside tables | 0/1 | 0/2 | 0/1 | / |
| Bed rails | 0/1 | 0/2 | 0/1 | / | |
| Toilet washbasins | 1/1 | 0/1 | 0/1 | 1.7*103 | |
| Flush button of the toilet bowl | 0/1 | 0/1 | 0/1 | / | |
| Return air outlet surface of the air purification device | 0/3 | 0/3 | 0/3 | / | |
| General wards | Bedside tables | 0/2 | 0/1 | 0/2 | / |
| Bed rails | 0/2 | 0/1 | 0/2 | / | |
| Toilet washbasins | 0/1 | 0/1 | 0/1 | / | |
| Flush button of the toilet bowl | 0/1 | 0/1 | 0/1 | / | |
| Return air outlet surface of the air purification device | 0/3 | 0/3 | 0/3 | / | |
Abbreviations: aRT-PCR, reverse transcription polymerase chain reaction; bB19V+, number of positive samples; cTotal, total number of samples; dRT-PCR, results (copy number/mL).
B19V RT-PCRa Results of Ambient Air Samples Before and After Disinfection
| Sampling Sites | Before Disinfection | 3 h Later | 5 h Later | 14 h Later | Resultsd |
|---|---|---|---|---|---|
| B19V +b/Totalc | |||||
| B19V isolation wards | 0/3 | 0/3 | 0/3 | 0/3 | / |
| General wards | 0/3 | 0/3 | 0/3 | 0/3 | / |
Abbreviations: aRT-PCR, reverse transcription polymerase chain reaction; bB19V+, number of positive samples; cTotal, total number of samples; dRT-PCR, results (copy number/mL).