| Literature DB >> 35454340 |
Diego González-Gil1, Javier Flores-Fraile1, Joaquín López-Marcos1.
Abstract
Background andEntities:
Keywords: interocclusal perception; interocclusal thickness; osseoperception; tactile sensibility
Mesh:
Year: 2022 PMID: 35454340 PMCID: PMC9027843 DOI: 10.3390/medicina58040501
Source DB: PubMed Journal: Medicina (Kaunas) ISSN: 1010-660X Impact factor: 2.948
Figure 1Pubmed Flowchart summarizing the review process.
Showing which kind of sensibility and prosthesis was involved in each investigation.
| Author and Year | Tactile Sensibility Studied | Natural Dentition Thresholds | Implant Prosthesis Thresholds | Complete Dentures Thresholds |
|---|---|---|---|---|
| Negahdari, 2019 | Active | Yes | Yes | No |
| Shala, 2017 | Active | Yes | Yes | Yes |
| Kazemi, 2013 | Active | Yes | Yes | No |
| Reveredo, 2013 | Active | Yes | Yes | No |
| Enkling, 2012 | Active | Yes | Yes | No |
| Grieznis, 2010 | Passive | Yes | Yes | No |
| Enkling, 2010 | Active | Yes | No | No |
| Batista, 2008 | Active | Yes | Yes | Yes |
| Enkling, 2007 | Active | Yes | Yes | No |
| El Sheik, 2004 | Passive | No | Yes | No |
Passive tactile sensibility (PTS) thresholds in natural dentition and implant prosthesis.
| Author and Year | Mean Value of PTS Threshold in Implants | Mean Value of PTS Threshold in Natural Dentition | Difference between Values |
|---|---|---|---|
| El Sheikh, 2004 | 10.9 N | - | - |
| Grieznis, 2010 | 2.5 N | 0.8 N | 1.7 N |
ATS in implant prosthesis and natural dentition.
| Author and Year | Mean Value of ATS Threshold in Implants | Mean Value of ATS Threshold in Natural Dentition |
|---|---|---|
| Negahdari, 2019 | 33.1 µ | 24.9 µ |
| Shala, 2017 | 30.5 µ | 13.5 µ |
| Kazemi, 2013 | 30 µ | 21.4 µ |
| Reveredo, 2013 | 24 µ | 12 µ |
| Enkling, 2012 | 20 µ | 16.9 µ |
| Enkling, 2010 | 20.2 µ | - |
| Batista, 2008 | 12 µ | 10 µ |
| Enkling, 2007 | 16.7 µ | 14.3 µ |
|
|
|
|
| 23.3 µ | 16.1 µ | 7.2 µ |
ATS thresholds in complete dentures.
| Author and Year | Mean Value of ATS Threshold in Complete Dentures |
|---|---|
| Shala, 2017 | 36 µ |
| Batista, 2008 | 92 µ |
| Total mean value of ATS threshold in complete dentures | 64 µ |
Total means values of active tactile sensibility (ATS).
| Prosthetic Situation | Total Mean Value of ATS Threshold | Standard Deviation |
|---|---|---|
| Complete dentures | 64 µ | 39.59 µ |
| Implant prosthesis | 23.3 µ | 7.42 µ |
| Natural dentition | 16.1 µ | 5.33 µ |