Literature DB >> 3543225

Accuracy of stereotaxic localisation using MRI and CT.

D J Wyper, J W Turner, J Patterson, B R Condon, K W Grossart, A Jenkins, D M Hadley, J O Rowan.   

Abstract

The accuracy of stereotaxic coordinates determined using the Leksell apparatus with CT and MRI was investigated using an Agar filled head phantom. Both imaging techniques were found to produce an accuracy of better than 2 mm with the exception of the Z coordinate as measured by CT (2.3 mm). This latter error is greater because of the 3 mm slice width used. Direct coronal views were used to determine Z more accurately using MRI. The measurement procedures are described and it is shown that the Leksell system of using orthogonal coordinates enables the scaling of images, which is particularly necessary with MRI, to be done easily.

Entities:  

Mesh:

Year:  1986        PMID: 3543225      PMCID: PMC1029134          DOI: 10.1136/jnnp.49.12.1445

Source DB:  PubMed          Journal:  J Neurol Neurosurg Psychiatry        ISSN: 0022-3050            Impact factor:   10.154


  7 in total

1.  Visualisation of stereotactic radiolesions by nuclear magnetic resonance.

Authors:  L Leksell; T Herner; D Leksell; B Persson; C Lindquist
Journal:  J Neurol Neurosurg Psychiatry       Date:  1985-01       Impact factor: 10.154

2.  Stereotaxis and nuclear magnetic resonance.

Authors:  L Leksell; D Leksell; J Schwebel
Journal:  J Neurol Neurosurg Psychiatry       Date:  1985-01       Impact factor: 10.154

3.  CT-guided stereotactic neurosurgery: experience in 24 cases with a new stereotactic system.

Authors:  D G Thomas; R E Anderson; G H du Boulay
Journal:  J Neurol Neurosurg Psychiatry       Date:  1984-01       Impact factor: 10.154

4.  The use of agar gel as a basic reference material for calibrating relaxation times and imaging parameters.

Authors:  R Mathur-De Vre; R Grimee; F Parmentier; J Binet
Journal:  Magn Reson Med       Date:  1985-04       Impact factor: 4.668

5.  Stereotaxic frame and computer software for CT-directed neurosurgical localization.

Authors:  R A Brown; T S Roberts; A G Osborn
Journal:  Invest Radiol       Date:  1980 Jul-Aug       Impact factor: 6.016

6.  Stereotaxis and tomography. A technical note.

Authors:  L Leksell; B Jernberg
Journal:  Acta Neurochir (Wien)       Date:  1980       Impact factor: 2.216

7.  Calculation of stereotactic coordinates from the computed tomographic scan.

Authors:  P L Gildenberg; H H Kaufman; K S Murthy
Journal:  Neurosurgery       Date:  1982-05       Impact factor: 4.654

  7 in total
  2 in total

1.  Stereotactic anatomy of the posterior cranial fossa. A study of the transcerebellar approach to the brainstem.

Authors:  A Gonçalves-Ferreira
Journal:  Acta Neurochir (Wien)       Date:  1991       Impact factor: 2.216

2.  An image fusion study of the geometric accuracy of magnetic resonance imaging with the Leksell stereotactic localization system.

Authors:  C Yu; Z Petrovich; M L Apuzzo; G Luxton
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.