| Literature DB >> 35430091 |
Saeko Shinozawa1, Yuki Moriyama2.
Abstract
Coronavirus disease (COVID-19) is a viral disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). SARS-CoV-2 can be detected by polymerase chain reaction (PCR) and isothermal nucleic acid amplification tests, including loop-mediated isothermal amplification (LAMP) and nicking endonuclease amplification reaction (NEAR) tests. Although PCR is the most sensitive and specific method and is generally considered to be the gold standard, it is time-consuming and costly. Isothermal nucleic acid amplification tests have lower sensitivity and specificity than PCR, but are less time-consuming and costly. We encountered three cases of SARS-CoV-2 infection in which the isothermal amplification test was positive but the PCR test was negative on the day of admission; however, the PCR test was positive the next day. These cases showed that some COVID-19 patients can test negative by PCR but positive using isothermal nucleic acid amplification methods. As PCR tests have the possibility of false-negative results, tests that use isothermal amplification methods which can be performed in a shorter time and at a lower cost than PCR tests, may be able to diagnose patients who have false negative PCR results.Entities:
Keywords: COVID-19; Case report; Isothermal amplification; Polymerase chain reaction; SARS-CoV-2
Mesh:
Substances:
Year: 2022 PMID: 35430091 PMCID: PMC8986487 DOI: 10.1016/j.jiac.2022.04.002
Source DB: PubMed Journal: J Infect Chemother ISSN: 1341-321X Impact factor: 2.065
Characteristics of the case patients and their SARS-CoV-2 test results.
| Case 1 | Case 2 | Case 3 | |
|---|---|---|---|
| Age (years) | 53 | 79 | 39 |
| Sex | Male | Female | Male |
| COVID-19 vaccination | No | Fully vaccinated | Fully vaccinated |
| Comorbidities | Cerebral hemorrhage | COPD | Cerebellar hemangioblastoma |
| Fever | 37.0 °C | 36.4 °C | 37.0 °C |
| Dyspnea | No | No | No |
| Cough | No | Yes | No |
| Other | Disturbance of consciousness | None | Vertigo |
| Pneumonia on CT scan | Yes | Yes | No |
| LAMP | ··· | Positive (Tt 17.24; Positive control Tt 11.54) | ··· |
| NEAR | Positive | ··· | Positive |
| PCR | Negative | Negative | Indeterminate (E, 41.5; N2, 0) |
| PCR test on the day after admission | Positive (Ct: E, 22.0; N2, 24.2) | Positive (Ct: E, 40.4; N2, 38.7) | Indeterminate (Ct: E, 0; N2, 44.2) |
COPD, chronic obstructive pulmonary disease; COVID-19, coronavirus disease; Ct, cycle threshold; CT, computed tomography; E, envelope; LAMP, loop-mediated isothermal amplification; N, nucleocapsid; NEAR, nicking endonuclease amplification reaction; PCR, polymerase chain reaction; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2, Tt, threshold time.
The LAMP test was performed using Loopamp 2019-nCoV detection kit (Eiken Chemical Co., Ltd, Tokyo, Japan).
The NEAR test was performed using ID-NOW (Abbott Diagnostics, Lake Forest, IL, USA).
The PCR test was performed using GeneXpert (Cepheid, Sunnyvale, CA, USA).