| Literature DB >> 35425973 |
Stoyan Kondov1, Aleksandar Dimov1, Friedhelm Beyersdorf1, Lars Maruschke2, Jan-Steffen Pooth1, Maximilian Kreibich1, Klaus Kaier3, Matthias Siepe1, Martin Czerny1, Bartosz Rylski1.
Abstract
OBJECTIVES: Our goal was to identify the inferior mesenteric artery diameter and number of patent lumbar arteries causing a significant type 2 endoleak to develop after infrarenal endovascular aneurysm repair.Entities:
Keywords: Coiling; EVAR; Inferior mesenteric artery; Lumbar arteries; Type 2 endoleak
Mesh:
Year: 2022 PMID: 35425973 PMCID: PMC9252125 DOI: 10.1093/icvts/ivac016
Source DB: PubMed Journal: Interact Cardiovasc Thorac Surg ISSN: 1569-9285
Figure 1:Inferior mesenteric artery diameter and number of patent lumbar arteries in patients undergoing EVAR. IMA: inferior mesenteric artery.
Figure 2:Number of patients presenting significant endoleak type II according to the inferior mesenteric artery diameter. Numbers at the bottom of the columns represent the number of patients with significant endoleak type II/number of all patients in the subgroup defined by inferior mesenteric artery diameter.
Results of univariable logistic regression analysis of factors associated with clinically significant type 2 endoleak
| Variables | 95% Confidence interval |
|
|---|---|---|
| Age | −0.005-0.002 | 0.469 |
| Sex | −0.103-0.167 | 0.642 |
| Diabetes | −0.099-0.074 | 0.782 |
| Hypertension | −0.133-0.150 | 0.901 |
| Smoking | −0.136-0.021 | 0.151 |
| AnaConDa ® stent graft system | −0.229-0.026 | 0.120 |
| Endurant ® stent graft system | −0.275-0.058 | 0.201 |
| Endurant IIs ® stent graft system | −0.247-0.033 | 0.195 |
| Zenith ® stent graft system | −0.379-0.061 | 0.133 |
| Aneurysm sack diameter | −0.002-0.005 | 0.509 |
| IMA diameter | 0.014-0.058 | 0.002 |
| Patent lumbar arteries | 0.016-0.069 | 0.002 |
IMA: inferior mesenteric artery.
Results of multiple logistic regression analysis of factors associated with developing clinically significant type 2 endoleak detected at the 6-month computer tomography angiography follow-up
| Variables | Odds ratio | 95% Confidence interval |
|
|---|---|---|---|
| Smoking | 0.672 | 0.270-1.587 | 0.203 |
| AnaConDa ® stent graft system | 0.680 | 0.221-2.353 | 0.602 |
| Endurant IIs ® stent graft system | 0.610 | 0.141-2.602 | 0.602 |
| Zenith ® stent graft system | 0.289 | 0.001-3.227 | 0.394 |
| IMA diameter | 1.755 | 1.320-2.463 | 0.001 |
| Patent lumbar arteries | 1.717 | 1.264-2.387 | 0.001 |
IMA: inferior mesenteric artery.
Figure 3:Number of patients with significant endoleak type II according to the number of patent lumbar arteries. Numbers at the bottom of the columns illustrate the number of patients with significant endoleak type II/the number of all patients in the subgroup defined by number of patent lumbar arteries. IMA: inferior mesenteric artery.
Figure 4:Receiver operating characteristics (ROC) curve analysis for the diameter of the inferior mesenteric artery relevant to endoleak type II, with an area under the ROC curve of 0.73 and nearest value to the upper left corner 3 mm with a sensitivity of 93.3% and a specificity of 65%. The closer the ROC curve is to the left upper corner, the higher is the test’s accuracy.