Literature DB >> 3541029

Breast masses: US-guided fine-needle aspiration biopsy.

B D Fornage, M J Faroux, A Simatos.   

Abstract

Real-time ultrasonography (US) was used to guide fine-needle aspiration biopsy of 111 breast masses and three axillary lymph nodes. The masses included 51 (45%) nonpalpable lesions. Two different guidance techniques were used, with satisfactory results. Lesions less than 1 cm in diameter could be accurately aspirated, and the method allowed quick and accurate cytologic characterization of solid breast masses. The sensitivity of the cytologic diagnosis of malignancy was 92%, and the specificity was 93%. US-guided fine-needle aspiration biopsy of breast masses should be routinely performed, since it can lead to earlier and cost-effective diagnosis of breast carcinoma at virtually no risk. Because of the accuracy of real-time US guidance, negative cytologic findings (i.e., satisfactory smears with benign cells) should be considered highly reliable in ruling out malignancy.

Entities:  

Mesh:

Year:  1987        PMID: 3541029     DOI: 10.1148/radiology.162.2.3541029

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

Review 1.  Percutaneous biopsies of the breast: state of the art.

Authors:  B D Fornage
Journal:  Cardiovasc Intervent Radiol       Date:  1991 Jan-Feb       Impact factor: 2.740

Review 2.  Vacuum-assisted breast biopsy for breast cancer.

Authors:  Hai-Lin Park; Jisun Hong
Journal:  Gland Surg       Date:  2014-05

3.  Ultrasound-guided biopsy of nonpalpable breast masses by surgeons.

Authors:  E D Staren
Journal:  Ann Surg Oncol       Date:  1996-09       Impact factor: 5.344

4.  Linear array-based real-time photoacoustic imaging system with a compact coaxial excitation handheld probe for noninvasive sentinel lymph node mapping.

Authors:  Mucong Li; Chengbo Liu; Xiaojing Gong; Rongqin Zheng; Yuanyuan Bai; Muyue Xing; Xuemin Du; Xiaoyang Liu; Jing Zeng; Riqiang Lin; Huichao Zhou; Shouju Wang; Guangming Lu; Wen Zhu; Chihua Fang; Liang Song
Journal:  Biomed Opt Express       Date:  2018-03-02       Impact factor: 3.732

5.  Handheld array-based photoacoustic probe for guiding needle biopsy of sentinel lymph nodes.

Authors:  Chulhong Kim; Todd N Erpelding; Konstantin Maslov; Ladislav Jankovic; Walter J Akers; Liang Song; Samuel Achilefu; Julie A Margenthaler; Michael D Pashley; Lihong V Wang
Journal:  J Biomed Opt       Date:  2010 Jul-Aug       Impact factor: 3.170

6.  Clinically occult breast carcinoma: diagnostic approaches and role of axillary node dissection.

Authors:  S Meterissian; B D Fornage; S E Singletary
Journal:  Ann Surg Oncol       Date:  1995-07       Impact factor: 5.344

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.