Literature DB >> 35405027

Combining navigator and optical prospective motion correction for high-quality 500 μm resolution quantitative multi-parameter mapping at 7T.

Lenka Vaculčiaková1, Kornelius Podranski1, Luke J Edwards1, Dilek Ocal2, Thomas Veale2,3, Nick C Fox2,3, Rainer Haak4, Philipp Ehses5, Martina F Callaghan6, Kerrin J Pine1, Nikolaus Weiskopf1,6,7.   

Abstract

PURPOSE: High-resolution quantitative multi-parameter mapping shows promise for non-invasively characterizing human brain microstructure but is limited by physiological artifacts. We implemented corrections for rigid head movement and respiration-related B0-fluctuations and evaluated them in healthy volunteers and dementia patients.
METHODS: Camera-based optical prospective motion correction (PMC) and FID navigator correction were implemented in a gradient and RF-spoiled multi-echo 3D gradient echo sequence for mapping proton density (PD), longitudinal relaxation rate (R1) and effective transverse relaxation rate (R2*). We studied their effectiveness separately and in concert in young volunteers and then evaluated the navigator correction (NAVcor) with PMC in a group of elderly volunteers and dementia patients. We used spatial homogeneity within white matter (WM) and gray matter (GM) and scan-rescan measures as quality metrics.
RESULTS: NAVcor and PMC reduced artifacts and improved the homogeneity and reproducibility of parameter maps. In elderly participants, NAVcor improved scan-rescan reproducibility of parameter maps (coefficient of variation decreased by 14.7% and 11.9% within WM and GM respectively). Spurious inhomogeneities within WM were reduced more in the elderly than in the young cohort (by 9% vs. 2%). PMC increased regional GM/WM contrast and was especially important in the elderly cohort, which moved twice as much as the young cohort. We did not find a significant interaction between the two corrections.
CONCLUSION: Navigator correction and PMC significantly improved the quality of PD, R1, and R2* maps, particularly in less compliant elderly volunteers and dementia patients.
© 2022 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  7T; FID navigator; multi-parameter mapping; physiological artifacts; prospective motion correction; quantitative MRI

Mesh:

Year:  2022        PMID: 35405027     DOI: 10.1002/mrm.29253

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   3.737


  1 in total

1.  Real-time shimming with FID navigators.

Authors:  Tess E Wallace; Tobias Kober; Jason P Stockmann; Jonathan R Polimeni; Simon K Warfield; Onur Afacan
Journal:  Magn Reson Med       Date:  2022-09-12       Impact factor: 3.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.