| Literature DB >> 35400085 |
Anita Singh1, Tanmay Majmudar2,3, Rachel Magee2, Bernard Gonik4, Sriram Balasubramanian2.
Abstract
Background Characterizing the biomechanical failure responses of neonatal peripheral nerves is critical in understanding stretch-related peripheral nerve injury mechanisms in neonates. Objective This in vitro study investigated the effects of prestretch magnitude and duration on the biomechanical failure behavior of neonatal piglet brachial plexus (BP) and tibial nerves. Methods BP and tibial nerves from 32 neonatal piglets were harvested and prestretched to 0, 10, or 20% strain for 90 or 300 seconds. These prestretched samples were then subjected to tensile loading until failure. Failure stress and strain were calculated from the obtained load-displacement data. Results Prestretch magnitude significantly affected failure stress but not the failure strain. BP nerves prestretched to 10 or 20% strain, exhibiting significantly lower failure stress than those prestretched to 0% strain for both prestretch durations (90 and 300 seconds). Likewise, tibial nerves prestretched to 10 or 20% strain for 300 seconds, exhibiting significantly lower failure stress than the 0% prestretch group. An effect of prestretch duration on failure stress was also observed in the BP nerves when subjected to 20% prestretch strain such that the failure stress was significantly lower for 300 seconds group than 90 seconds group. No significant differences in the failure strains were observed. When comparing BP and tibial nerve failure responses, significantly higher failure stress was reported in tibial nerve prestretched to 20% strain for 300 seconds than BP nerve. Conclusion These data suggest that neonatal peripheral nerves exhibit lower injury thresholds with increasing prestretch magnitude and duration while exhibiting regional differences. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. ( https://creativecommons.org/licenses/by/4.0/ ).Entities:
Keywords: brachial plexus; injury; neonates; prestretch; stretch; tibial nerve
Year: 2022 PMID: 35400085 PMCID: PMC8993512 DOI: 10.1055/s-0042-1743132
Source DB: PubMed Journal: J Brachial Plex Peripher Nerve Inj ISSN: 1749-7221
Fig. 1( A ) Schematic of the experimental setup including the uniaxial tensile testing machine and ( B ) diagram detailing the sample size for the various experimental groups.
Details of the number of brachial plexus (BP) and tibial nerve samples per experimental groups that underwent failure testing without slippage
| Nerve tissue | Group A: failure only | Group B: 10% (90 seconds) | Group C: 10% (300 seconds) | Group D: 20% (90 seconds) | Group E: 20% (300 seconds) |
|---|---|---|---|---|---|
| BP | 41 | 15 | 11 | 15 | 17 |
| Tibial | 17 | 5 | 6 | 5 | 12 |
Note: For groups B to E, the magnitude and duration of prestretch are also shown. For example, 10% refers to the prestretch strain level and 90 seconds refers to the duration of prestretch.
Fig. 2Exemplar stress–strain responses obtained during failure tensile testing of neonatal brachial plexus (BP) and tibial nerves that were subjected to no prestretch (failure only) or prestretch to 10% or 20% strain for 90 (top) or 300 seconds (bottom). Label A for each curve indicates failure stress and the corresponding failure strain.
Fig. 3Mean ± standard error of mean (SEM) values of ( A ) failure stress and ( B ) failure strain observed for brachial plexus (BP) nerve in various experimental groups when subjected to failure tensile testing. SEM values are shown as error bars. Significant differences ( p < 0.05) are indicated using a horizontal solid line above the bars.
Fig. 4Mean ± standard error of mean (SEM) values of ( A ) failure stress and ( B ) failure strain observed for tibial nerve in various experimental groups when subjected to failure tensile testing. SEM values are shown as error bars. Significant differences ( p < 0.05) are indicated using a horizontal solid line above the bars.
Fig. 5Comparison of biomechanical failure responses of neonatal brachial plexus (BP) and tibial nerve for the various experimental groups. Mean ± standard error of mean (SEM) values of ( A ) failure stress and ( B ) failure strain observed during failure tensile testing. SEM values are shown as error bars. Significant differences ( p < 0.05) between nerve tissues are indicated using a horizontal solid line above the bars.