| Literature DB >> 35399552 |
Beshada Rago Jima1, Hamid Yimem Hassen2, Paluku Bahwere3, Seifu Hagos Gebreyesus1.
Abstract
Mid-upper arm circumference (MUAC) is an age-sensitive anthropometric measurement in infants. However, exact age is difficult to know, particularly in low-income countries. We evaluated the diagnostic accuracy of an age-independent mid-upper arm circumference-to-length (MUAC/L) ratio measurement in detecting wasting among infants aged 1-6 months in Ethiopia. A facility-based diagnostic accuracy study was conducted on 467 in-patient infants aged 1-6 months from March to May 2019. The receiver operating characteristic (ROC) curve was used to evaluate the ability of MUAC/L to detect wasting. Sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and positive and negative predictive values were calculated. The magnitude of severe wasting was 21⋅6 % and moderate wasting was 13⋅0 %. The area under the ROC curve (AUC) of MUAC/L was 0⋅77 (95 % CI 0⋅73, 0⋅81) for detecting moderate wasting and 0⋅92 (95 % CI 0⋅89, 0⋅94) for detecting severe wasting. MUAC/L had a sensitivity of 91⋅1 % (95 % CI 81⋅3, 94⋅4), a specificity of 84⋅7 % (95 % CI 80⋅6, 88⋅2), a positive likelihood ratio of 5⋅82 (95 % CI 4⋅53, 7⋅48) and a negative likelihood ratio of 0⋅13 (95 % CI 0⋅07, 0⋅22) in total infants. The optimal MUAC/L cut-off was <0⋅190 for boys and <0⋅185 for girls. MUAC/L had an AUC of 0⋅77 and 0⋅92 in predicting moderate and severe wasting in infants aged 1-6 months, respectively. Using MUAC/L to treat Ethiopian infants with severe wasting and infants with similar characteristics in other countries could improve treatment coverage.Entities:
Keywords: AUC, area under ROC curve; Diagnosis; IQR, interquartile range; Infant; MUAC, mid-upper arm circumference; MUAC-to-length; MUAC/L, mid-upper arm circumference-to-length; ROC and wasting; ROC, receiver operating characteristic; WHO, World Health Organization; WLZ, weight-for-length Z-score
Mesh:
Year: 2022 PMID: 35399552 PMCID: PMC8943582 DOI: 10.1017/jns.2022.21
Source DB: PubMed Journal: J Nutr Sci ISSN: 2048-6790
Median comparison of age, weight, length, MUAC, WLZ and MUAC/L between boys and girls and their nutritional status
| Characteristics | Male ( | Female ( | Total ( | |
|---|---|---|---|---|
| Median (IQR) | Median (IQR) | Median (IQR) | ||
| Age (months) | 3⋅2 (2⋅2–4⋅7) | 3⋅3 (2⋅3–4⋅8) | 0⋅515 | 3⋅3 (2⋅3–4⋅8) |
| Weight (kg) | 5⋅4 (4⋅5–6⋅0) | 5⋅0 (4⋅0–5⋅9) | 0⋅059 | 5⋅2 (4⋅2–6⋅0) |
| Length (cm) | 58⋅5 (55⋅0–63⋅0) | 58⋅2 (54⋅5–62⋅0) | 0⋅399 | 58⋅4 (55–62⋅5) |
| MUAC (mm) | 120 (107–130) | 116 (100–130) | 0⋅115 | 119 (103–130) |
| WLZ | −1⋅08 (−2⋅57–0.39) | −1⋅30 (−2⋅8–0⋅19) | 0⋅325 | −1⋅27 (−2⋅6–0⋅34) |
| MUAC/L | 0⋅203 (0⋅181–0⋅216) | 0⋅199 (0⋅214–0⋅174) | 0⋅233 | 0⋅200 (0⋅216–0⋅159) |
| Nutritional status, | ||||
| Wasting | 79 (32⋅7) | 83 (36⋅6) | 0⋅371 | 162 (34⋅6) |
| Severe | 48 (19⋅9) | 53 (23⋅4) | 0⋅424 | 101 (21⋅6) |
| Moderate | 31 (12⋅8) | 30 (13⋅2) | 0⋅898 | 61 (13⋅0) |
| Normal | 162 (67⋅2) | 143 (63⋅2) | 0⋅278 | 305 (65⋅4) |
IQR, interquartile range; MUAC, mid-upper arm circumference; MUAC/L, mid-upper arm circumference-to-length ratio; WLZ, weight-for-length Z-score.
P-values are based on Mann–Whitney U-test.
Fig. 1.Receiver's operating characteristic curve of mid-upper arm circumference-to-length (MUAC/L) ratio for detecting moderate wasting against weight-for-length in boys and girls.
Fig. 2.Receiver's operating characteristic curves of mid-upper arm circumference-to-length (MUAC/L) ratio for detecting severe wasting against weight-for-length in boys and girls.
Diagnostic accuracy measures for different cut-offs of MUAC/L ratio for detecting moderate and severe wasting among infants aged 1–6 months (n 467)
| MUAC/L | Moderate wasting | Severe wasting | ||||
|---|---|---|---|---|---|---|
| Cut-offs | Sensitivity | Specificity | YI | Sensitivity | Specificity | YI |
| <0⋅220 | 96⋅7 | 24⋅6 | 0⋅213 | 99⋅0 | 21⋅0 | 0⋅200 |
| <0⋅215 | 90⋅2 | 36⋅4 | 0⋅266 | 98⋅0 | 32⋅0 | 0⋅300 |
| <0⋅210 | 85⋅2 | 49⋅5 | 0⋅347 | 97⋅0 | 43⋅7 | 0⋅407 |
| <0⋅205 | 80⋅3 | 60⋅3 | 0⋅406 | 97⋅0 | 53⋅6 | 0⋅506 |
| <0⋅200 | 73⋅8 | 69⋅8 | 0⋅436 | 95⋅0 | 62⋅6 | 0⋅576 |
| <0⋅195 | 54⋅1 | 80⋅7 | 0⋅348 | 94⋅1 | 74⋅9 | 0⋅690 |
| <0⋅190 | 42⋅6 | 85⋅9 | 0⋅285 | 93⋅1 | 80⋅9 | 0⋅740 |
| <0⋅185 | 34⋅4 | 88⋅5 | 0⋅229 | 91⋅1 | 84⋅7 | 0⋅758 |
| <0⋅180 | 31⋅1 | 92⋅5 | 0⋅236 | 83⋅2 | 88⋅8 | 0⋅720 |
| <0⋅175 | 24⋅6 | 93⋅8 | 0⋅189 | 76⋅2 | 90⋅4 | 0⋅666 |
MUAC/L, mid-upper arm circumference; YI, Youden index.
Optimal cut-off values, the area under the ROC curves, sensitivities, specificities, positive and negative likelihood ratio and positive and negative predictive values of MUAC/L associated with severe wasting among infants aged 1–6 months
| Sex | Nutritional status | Cut-off level | AUC (95 % CI) | Sensitivity (95 % CI) | Specificity (95 % CI) | LR+ (95 % CI) | LR− (95 % CI) | PPV (95 % CI) | NPV (95 % CI) | |
|---|---|---|---|---|---|---|---|---|---|---|
| Boys | Moderate wasting | 31 (12⋅8) | <0⋅206 | 0⋅70 (0⋅61, 0⋅78) | 77⋅4 (58⋅9, 90⋅4) | 62⋅3 (54⋅4, 69⋅8) | 2⋅06 (1⋅56, 2⋅71) | 0⋅36 (0⋅19, 0⋅70) | 30⋅1 (24⋅6, 36⋅1) | 93⋅0 (87⋅2, 96⋅2) |
| Severe wasting | 48 (19⋅9) | <0⋅190 | 0⋅88 (0⋅84, 0⋅93) | 93⋅8 (82⋅8, 98⋅7) | 82⋅9 (76⋅8, 87⋅9) | 5⋅48 (3⋅98, 7⋅54 | 0⋅07 (0⋅02, 0⋅23) | 57⋅7 (49⋅7, 65⋅2) | 98⋅2 (94⋅7, 99⋅4) | |
| Girls | Moderate wasting | 30 (13⋅3) | <0⋅198 | 0⋅72 (0⋅63, 0⋅81) | 70⋅0 (50⋅6, 85⋅3) | 74⋅1 (66⋅1, 81⋅1) | 2⋅71 (1⋅88, 3⋅89) | 0⋅40 (0⋅23, 0⋅70) | 34⋅2 (26⋅5, 42⋅7) | 92⋅8 (88⋅1, 95⋅7) |
| Severe wasting | 53 (23⋅4) | <0⋅185 | 0⋅86 (0⋅81, 0⋅91) | 88⋅7 (77⋅0, 95⋅7) | 83⋅2 (76⋅8, 88⋅5) | 5⋅29 (3⋅74, 7⋅47) | 0⋅14 (0⋅06, 0⋅29) | 61⋅8 (53⋅4, 69⋅5) | 96⋅0 (91⋅9, 98⋅1) | |
| Total | Moderate wasting | 61 (13⋅0) | <0⋅201 | 0⋅72 (0⋅66, 0⋅78) | 73⋅8 (60⋅9, 84⋅2) | 69⋅8 (64⋅3, 74⋅9) | 2⋅45 (1⋅95, 3⋅07) | 0⋅38 (0⋅24, 0⋅58) | 32⋅9 (28⋅1, 38⋅1) | 93⋅0 (89⋅7, 95⋅3) |
| Severe wasting | 101 (21⋅6) | <0⋅185 | 0⋅87 (0⋅83, 0⋅90) | 91⋅1 (81⋅3, 94⋅4) | 84⋅7 (80⋅6, 88⋅2) | 5⋅82 (4⋅53, 7⋅48) | 0⋅13 (0⋅07, 0⋅22) | 61⋅6 (55⋅5, 67⋅3 | 96⋅6 (94⋅2, 98⋅0) |
AUC, area under ROC curve; CI, confidence interval; LR+, positive likelihood ratio; LR−, negative likelihood ratio; MUAC/L, mid-upper arm circumference; NPV, negative predictive value; PPV, positive predictive value; ROC, receiver operating characteristic.