Nathan D Stuempfig1, Sara Toulouie2, Edward J Durant1, Nur-Ain Nadir1.
Abstract
BACKGROUND: With the advent of variant strains such as Delta and Omicron, there have been renewed concerns regarding transmission of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV2) (coronavirus disease 2019 (COVID-19)) disease to healthcare professionals, particularly during intubation procedures. Several forms of barrier protection aimed at decreasing the spread of aerosolized droplets were developed during the early onset of the pandemic.Entities:
Keywords: barrier; covid-19; intubation; protection; simulation
Year: 2022 PMID: 35399408 PMCID: PMC8980240 DOI: 10.7759/cureus.22817
Source DB: PubMed Journal: Cureus ISSN: 2168-8184
Figure 1Clear plexiglass box
Figure 2PVC frame with drape
PVC: polyvinyl chloride
Figure 3Plastic drape
Figure 4Ease of setup for direct laryngoscopy
PVC: polyvinyl chloride
Figure 7Ease of mastery using video laryngoscopy
PVC: polyvinyl chloride
Figure 8Preference of barrier device for any method of intubation
PVC: polyvinyl chloride
Average times to barrier device set up, 1st pass intubation, and BVM with direct and indirect laryngoscopy for each intubation barrier device.
BVM: bag valve mask; PVC: polyvinyl chloride
| Barrier device type | Plastic drape | PVC cube with plastic drape | Fiberglass box | |||
| Direct | Indirect | Direct | Indirect | Direct | Indirect | |
| Average time (s) | ||||||
| Device setup | 32.4 + 4.12 | 34 + 4.12 | 40 + 8.1 | 38.7 + 6.1 | 11.3 + 1.59 | 9.5 + 2.07 |
| 1st pass intubation | 46 + 4.4 | 38.6 + 3.96 | 45.5+ 4.5 | 41 + 4.3 | 56.5 + 7.4 | 52 + 3.9 |
| BVM | 48.6 + 5.57 | 41.5 + 6.8 | 48.8 + 5.1 | 42.8 + 5.9 | 63 + 5.6 | 65 + 8.6 |
Direct comparison of barrier devices for average complete intubation and ventilation
*denotes statistical significance PVC: polyvinyl chloride
| Laryngoscopy approach | Barrier device comparison | Setup to intubation/ventilation times (P-value) |
| Direct | Plastic drape vs PVC cube and drape | 0.963 |
| Direct | Plastic drape vs fiberglass box | <0.001* |
| Direct | PVC cube and drape vs fiberglass box | <0.001* |
| Video | Plastic drape vs PVC cube and drape | 0.974 |
| Video | Plastic drape vs fiberglass box | <0.001* |
| Video | PVC cube and drape vs fiberglass box | <0.001* |
Figure 9Direct comparison of barrier devices for average completed intubation and ventilation times using direct laryngoscopy
*demonstrates statistical significance PVC: polyvinyl chloride
Figure 10Direct comparison of barrier devices for average complete intubation and ventilation times using video laryngoscopy
*demonstrates statistical significance PVC: polyvinyl chloride