Eleanor Milnes-Smith1, Corinne A Stone2, Colin R Willis2, Susan Perkin1. 1. Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, Oxford OX1 3QZ, United Kingdom. 2. Defence Science and Technology Laboratory, Porton Down, Salisbury, Wiltshire SP4 0JQ, United Kingdom.
Abstract
Surface reconstruction is the rearrangement of atoms or molecules at an interface in response to a stimulus, driven by lowering the overall free energy of the system. Perfluoroalkyl acrylate polymers with short side chains undergo reconstruction at room temperature when exposed to water. Here, we use contact angle aging to examine the liquid- and temperature- dependency of surface reconstruction of plasma polymerized perfluoroalkyl acrylates. We use a first order kinetic model to examine the dynamics of reconstructive processes. Our results show that, above the bulk melting point of the polymers, the contact angles of both polar and nonpolar (hydrocarbon) liquids show a time dependency well fit by the model. We conclude that surface reconstruction can be driven by the preferential segregation of hydrocarbon and fluorocarbon moieties as well as by polar interactions. This has implications in terms of using fluorocarbons to design oleophobic surfaces (and vice versa) and in terms of designing fluorocarbon and/or hydrocarbon surfaces with switchable wettability.
Surface reconstruction is the rearrangement of atoms or molecules at an interface in response to a stimulus, driven by lowering the overall free energy of the system. Perfluoroalkyl acrylate polymers with short side chains undergo reconstruction at room temperature when exposed to water. Here, we use contact angle aging to examine the liquid- and temperature- dependency of surface reconstruction of plasma polymerized perfluoroalkyl acrylates. We use a first order kinetic model to examine the dynamics of reconstructive processes. Our results show that, above the bulk melting point of the polymers, the contact angles of both polar and nonpolar (hydrocarbon) liquids show a time dependency well fit by the model. We conclude that surface reconstruction can be driven by the preferential segregation of hydrocarbon and fluorocarbon moieties as well as by polar interactions. This has implications in terms of using fluorocarbons to design oleophobic surfaces (and vice versa) and in terms of designing fluorocarbon and/or hydrocarbon surfaces with switchable wettability.
Reconstruction of polymer
surfaces is a well-known phenomenon which
has been of great interest for some time in developing so-called “smart”
surfaces, which undergo changes in response to an applied stimulus,
such as temperature, electric potential, humidity, or certain liquids.[1−9] These are useful in a wide variety of contexts, including oil/water
separation,[10−12] anti-biofouling,[13,14] and biomedical
applications including drug delivery and implants.[15−18] There are, however, also circumstances
in which surface reconstruction results in a loss of desirable functionality.This paper focuses on perfluoroalkyl acrylate (PFAC-n, where n is the length of the perfluoroalkyl chain)
polymers, which are used in industry to manufacture low surface energy
materials. The generic PFAC-n monomer structure is
shown in Figure .
Coulson et al. developed a method using pulsed plasma polymerization
to graft the PFAC-8 polymer to a variety of substrates.[19] Plasma polymerization is favored by industry
as it is a solvent-free process which can synthesize a polymer and
graft it to a substrate in a single step.[20] Because it is a gas phase process, it is independent of substrate
geometry and produces uniform coatings with tunable thickness.[21] Using the pulsed technique, rather than a more
conventional, continuous wave plasma process has the additional advantage
that fragmentation of the monomer species is kept to a minimum and
the chemical structure of the polymer closely resembles those synthesized
in the solution-phase.[22,23] The coating developed by Coulson
et al. is super-omniphobic and has been used successfully at the industrial
scale to produce liquid repellent coatings for clothing, electronics,
and filtration devices.[24,25] However, compounds
with fluoroalkyl chains of eight or more carbons are now known to
bioaccumulate, meaning that shorter chain alternatives must be sought.[26,27] The liquid-repellency of the PFAC-8 polymer hinges on the fact that
the low surface CF3 groups preferentially segregate at
the surface and the fluoroalkyl side chains crystallize, effectively
locking the structure in place.[28,29] Compounds with fewer
than eight perfluorinated carbons are amorphous under ambient conditions.
Work by Honda and co-workers on PFAC-n polymers and
similar compounds has shown that these shorter chain (n < 8) analogues are prone to surface reconstruction when exposed
to water.[30−32] Strong polar interactions induce the migration of
the acrylic groups to the surface and the liquid spreads. A schematic
of this process is shown in the bottom half of Figure .
Figure 1
Chemical structure of the perfluoroalkyl acrylate
(PFAC-n) monomer and Schematic showing reconstruction
of a PFAC-n surface upon exposure to water. The blue
cylinders represent
the perfluoroalkyl chain, and the red sections represent the acrylate
linkage to the backbone.
Chemical structure of the perfluoroalkyl acrylate
(PFAC-n) monomer and Schematic showing reconstruction
of a PFAC-n surface upon exposure to water. The blue
cylinders represent
the perfluoroalkyl chain, and the red sections represent the acrylate
linkage to the backbone.A number of other authors
have used changes in contact angle and
contact angle hystereses to examine the reconstruction of polymer
surfaces,[30−35] and a recent paper by Butt et al. proposed a simple first order
kinetic model to relate changes in contact angle (θ) to spontaneous
adaptation of a surface in contact with a liquid or vapor.[36] Adaptation in this context could mean polymer
reconstruction but may also refer to swelling of the polymer,[37−40] adsorption of vapor/liquid on the surface (or replacement of adsorbed
species),[32,41,42] surfactants
binding at both the solid–liquid and liquid–vapor interfaces,[43,44] and ordering of the liquid molecules at the solid–liquid/liquid–vapor
interfaces.[45,46] These effects may be concurrent,
and it may not be possible to separate out these effects. The time
scale of adaptive processes is characteristic of the system, and measurements
of surface properties such as wetting will necessarily mirror this
time scale. The model proposed by Butt et al.[36] assumes that the solid–liquid surface energy, γSL, relaxes from its initial state, γSL(0),
to its final state, γSL(∞), following first
order kinetics such thatwhere t is time, τSL is the characteristic
relaxation time of the system, andThe corresponding
change in θ therefore
varies with t such thatwhereIn addition to Butt’s first order model, the solid surface
energies will also be evaluated using a more commonly used approach:
the Owens–Wendt–Rabel–Kaelble (OWRK) method.[47,48] This allows γSV to be calculated (subject to several
assumptions) in the absence of liquid- and/or time-dependent effects.
Here, it is assumed that surface energy can be split into two distinct
contributions from polar and dispersive forces such thatIt is further assumed that the solid–liquid
surface energy, γSL, is the geometric mean of the
solid–vapor surface energy, γSV, and the liquid–vapor
surface energy, γLV, such thatThis equation may be combined with the Young equation and
rearranged
to give the linear equationallowing the values
of γSVp and γSVp to be extracted
by measuring the values of θ for two or more liquids with known
values of γLVp and γLVd.[49] This is useful in the context
of examining surface reconstruction as it is expected that the migration
of the acrylate groups to the surface would result in an increase
in γSVp.While the work by Honda et al. focused on the role of polar
liquids
at room temperature, the work in this investigation also encompasses
the role of temperature in governing molecular mobility (and hence
surface reconstruction), and the role of nonpolar liquids. Furthermore,
whereas previous studies have focused on polymers synthesized in the
solution phase, the work here focuses on polymers synthesized via
pulsed plasma polymerization–which can be rather different
in terms of morphology. Although this investigation is focused on
a specific set of substrates, the findings can be generalized and
applied to a wide range of systems.In summary, this paper investigates
the time-, temperature-, and
liquid-dependency of contact angles on plasma polymerized perfluoroalkyl
acrylates with variable side chain lengths. The paper is laid out
in three parts: First, since wetting behavior is dependent on the
chemical composition, topography, and phase behavior of a surface,
a detailed characterization of the PFAC-n polymers
has been performed using angle-resolved X-ray photoelectron spectroscopy
(ARXPS), atomic force microscopy (AFM), and differential scanning
calorimetry (DSC), as well as some basic contact angle measurements.
Second, the time dependent contact angles, θ(t), at variable temperatures, T, are presented, and
the questions of whether surface reconstruction has taken place and
what drives surface reconstruction are addressed. Third and finally,
the contact angle data is then examined using Butt’s first
order model and is related to the kinetics of surface reconstruction.
Materials and Methods
Materials
The
general structure for perfluoroalkyl-n-acrylate (PFAC-n) monomers and polymers
is shown in Figure . Monomers with n = 6, 8, and 10 were obtained from
Sigma-Aldrich Ltd. (≥97%), while the PFAC-4 monomer was obtained
from Fluorochem Ltd. (≥97%). All monomers were purified prior
to use by multiple freeze–thaw cycles.
Surface Synthesis
Polymer films were prepared via pulsed
plasma polymerization. An inductively coupled glass glow discharge
reactor (10 cm diameter, base pressure < 1 × 10–2 mbar) was connected to an Edwards two-stage rotary vacuum pump via
a thermocouple pressure gauge and a liquid nitrogen cold trap. Power
was supplied from a 13.56 MHz radio frequency generator which was
connected to a pulse generator, and to and L-C matching unit. The
chamber and monomer inlet were also enclosed in an oven. Prior to
use, the chamber was scrubbed with IPA and a 50 W air (2 × 10–1 mbar) plasma was run for 1 h.The samples to
be coated (glass slides for AFM, XPS, and contact angle measurements,
ground glass for DSC) were placed in the chamber inside the coils
and the whole system was evacuated to base pressure. Monomer vapor
was then introduced at pressure of 2 × 10–1 mbar (room temperature for n = 4 and 6, 30 °C
for n = 8, and 50 °C for n =
10). A brief, 30 s, continuous wave plasma was ignited (40 W) before
the pulse generator (ton = 40 μs, toff = 20 ms) was switched on and the plasma run for a further 10 min
(glass slides) or 2 h (ground glass). After this time, the RF generator
was switched off and the monomer vapor allowed to flow for 5 min before
the system was evacuated back to base pressure.
Solid-State 19F NMR
Experiments were carried
out using a Bruker Avance III spectrometer, operating at ∼376
MHz fF detection and using a 3.2 mm HFX probe. CFCl3 was used as an
external reference. Spectra were acquired with 16 scans, having a
90° pulse width of 2.5 μs and a delay time of less than
10 s. All spectra were acquired using magic angle spinning (MAS) at
a rate of 20 kHz.
X-ray Photoelectron Spectroscopy (XPS)
Survey spectra
were acquired using a Thermo Scientific K-Alpha spectrometer with
a takeoff angle of 90° to the surface normal. Angle-resolved
XPS (ARXPS) carbon 1s spectra were obtained using a Thermo Scientific
Theta Probe; spectra were acquired in parallel at angles from 27.5°
to 77.5° to the normal in 5° steps. To prevent damage to
the surfaces, the X-rays were rastered across the surface in a 16
× 16 grid with 500 μm between points. At each point, the
C 1s spectrum was measured for 60 s, giving a total acquisition
time of 256 min. The spectra at all points were summed to give a single,
angle-resolved spectrum. Data was analyzed using CasaXPS software.
Differential Scanning Calorimetry (DSC)
A PerkinElmer
PYRIS Diamond DSC was used in the thermal analysis of PFAC-n samples. The samples were loaded at −50 °C
and equilibrated for 2 min. The samples were then heated from −50
to 150 °C at a rate of 10 °C min–1, held
at 150 °C for 5 min, and then cooled to −50 °C at
a rate of 10 °C min–1. The samples were held
at −50 °C for 5 min, and the heating and cooling cycle
was then repeated once more. Data was analyzed using the PYRIS software
Atomic Force Microscopy (AFM)
Measurements were carried
out using a Digital Instruments Multimode NanoScope IIIb in tapping
mode. Tapping mode involves rastering an oscillating cantilever across
the surface; the oscillations are then damped by interactions with
the surface. The cantilevers used had a force constant of 40 N m–1 and a resonant frequency of 325 kHz. Data analysis
was carried out in the NanoScope analysis program.
Contact Angle
(CA) Measurements
Initial room temperature
contact angle measurements were performed using a Krüss DSA25
goniometer using water and n-dodecane as probe liquids.
Static contact angles were measured by dispensing a 5 μL drop
on the surface, while advancing and receding contact angles were measured
by dispensing and then retracting a 5 μL drop at a rate of 0.5
μL s–1; the largest angle during dispensation
and the smallest angle during retraction were taken as the advancing
and receding CAs, respectively. Each measurement was repeated five
times on three different samples, each made during a different deposition.Variable temperature static contact angle measurements were carried
out using a Krüss DSA100 goniometer fitted with a TC40 temperature-controlled
chamber and operated under a low flow of dry air. Measurements were
performed at temperatures from 20 to 100 °C at intervals of 10
°C. Prior to each measurement, the surfaces were allowed to reach
thermal equilibrium over a period of 10 min and a thermal camera was
used to ascertain whether this was the case. The probe liquids from
room temperature experiments were exchanged for the less volatile
ethylene glycol (“EG”, Sigma-Aldrich Ltd., 99.8%) and n-hexadecane (“HD”, Sigma-Aldrich, Ltd., ≥99%),
and the drop volume was decreased to 2 μL to promote more rapid
thermal equilibrium with the surface. The initial measurements of
θ demonstrated that the experimental scatter was greater across
different surfaces than across the same surface, so measurements were
performed on a single, representative surface and repeated three times.
Results and Discussion
Characterization of PFAC-n Surfaces
Chemical Composition
Solid-state 19F NMR
spectra were recorded for each of the PFAC-n polymers
(n = 4, 6, 8, 10) in order to interrogate the local
F environments in the different polymers. The spectra for all PFAC-n polymers (Figure S1.2) revealed
contributions from four different fluorine environments: CH2—CF2, CF2—CF2, CF3—CF2, and C 1s CF2—CF3. Notably, there were no contributions in the solid-state 19F NMR spectra from C(CF3)3, CF(CF3)2, or CF moieties, which indicates that no
observable fragmentation or cross-linking of the monomer species had
taken place. Similarly, deconvolution of the XPS spectra acquired
at a takeoff angle normal to the surface, shown in Figure S1.2, reveal contributions from six carbon environments; CF3, CF2, C=O, C—O, C—CF, and C—CH. This is also
consistent with no observable fragmentation of the monomer species
having occurred during the deposition process and indicates that the
pulsed plasma technique has produced polymers which are chemically
similar to those produced via solution-phase synthesis.Angle-resolved
XPS carbon 1s spectra were carried out for each of the PFAC-n polymers (n = 4, 6, 8, 10), in order
to interrogate the local chemical composition of the surface and the
variation of composition with depth. An example spectrum for PFAC-6
is shown in Figure along with a plot of the variation in concentration of the CF3 and C—CH species, which sit at opposite ends of the
monomer unit–the full data can be viewed in Figures S1.3 and S1.4.
Figure 2
(a) Angle-resolved C 1s XPS spectra of
a PFAC-6 polymer surface
acquired in parallel at angles between 22.5° (blue) and 77.5°
(red) to the surface normal at intervals of 5°. To account for
the decrease in signal intensity, a Shirley background subtraction
was performed, and the area under the peaks was normalized. (b) Variation
with penetration depth, d, of the concentration of
the CF3 and C—CH species. Penetration depth
is defined as the depth at which 63% of the signal originates and
is estimated as d ∼ λ sin θ where
θ is the takeoff angle relative to the surface and λ is
the electron inelastic mean free path. In fluoropolymers where the
photoelectrons are excited from the C 1s level by Al Kα
radiation, λ ∼ 3 nm.[50]
(a) Angle-resolved C 1s XPS spectra of
a PFAC-6 polymer surface
acquired in parallel at angles between 22.5° (blue) and 77.5°
(red) to the surface normal at intervals of 5°. To account for
the decrease in signal intensity, a Shirley background subtraction
was performed, and the area under the peaks was normalized. (b) Variation
with penetration depth, d, of the concentration of
the CF3 and C—CH species. Penetration depth
is defined as the depth at which 63% of the signal originates and
is estimated as d ∼ λ sin θ where
θ is the takeoff angle relative to the surface and λ is
the electron inelastic mean free path. In fluoropolymers where the
photoelectrons are excited from the C 1s level by Al Kα
radiation, λ ∼ 3 nm.[50]All the PFAC-n polymers show a
variation in composition
within the 2 nm from the interface toward the bulk. The concentration
of CF3 is approximately anticorrelated to that ofCHn and is found in excess at the surface. The anticorrelation
of the concentration of the functional groups at opposite ends of
the monomer unit suggests the side chains have a general orientation
with the CF3 groups toward the surface, and the other end
of the side chain toward the bulk. However, the concentrations of
the other C 1s environments (shown in the Supporting Information) display a far more complex behavior that would
be expected in the case that the side chains are completely straight
and/or aligned perfectly perpendicular to the surface. Rather, they
likely possess some degree of tilt and flexibility, and variation
in orientation. Unfortunately, accounting for this disorder significantly
complicates any quantitative analysis of these results and for this
reason we have opted for a solely qualitative discussion.PFAC-4
overall displays less depth-dependent behavior than the
other three polymer surfaces. Having fewer carbon units in the side
chain reduces the strength of the intermolecular interactions between
side chains and reduces the enthalpic benefit of side chain crystallization.
Thermal Characterization
In order to interrogate the
phase state and phase transitions of the PFAC-n polymers we performed
DSC measurements. Figure shows the first heating (top curve) and first cooling (bottom
curve) cycle of the PFAC-n polymers; background subtracted spectra
are shown inset for PFAC-4, 6, and 8 to allow the lower intensity
peaks to be clearly shown. The first heating cycle corresponds to
the behavior investigated during the variable temperature contact
angle aging experiments, while the cooling curve shows which of these
transitions are reversible, thermodynamic transitions–second
heating curves can be viewed in the Supporting Information.
Figure 3
DSC traces (endothermic up) for the first heating and
cooling cycle
of (a) PFAC-4, (b) PFAC-6, (c) PFAC-8, and (d) PFAC-10 polymers. Background
subtracted spectra are included as an inset. The difference between
the heating and cooling curves gives an indication of which transitions
are reversible. In the case of PFAC-4 and -6, all peaks that appear
in the heating cycle are found in the cooling cycle, while PFAC-8
and −10 show significant differences between the two, indicating
that they are kinetically trapped in nonequilibrium states.
DSC traces (endothermic up) for the first heating and
cooling cycle
of (a) PFAC-4, (b) PFAC-6, (c) PFAC-8, and (d) PFAC-10 polymers. Background
subtracted spectra are included as an inset. The difference between
the heating and cooling curves gives an indication of which transitions
are reversible. In the case of PFAC-4 and -6, all peaks that appear
in the heating cycle are found in the cooling cycle, while PFAC-8
and −10 show significant differences between the two, indicating
that they are kinetically trapped in nonequilibrium states.The first heating cycle of PFAC-10 shows a broad
melting peak across
a wide range of temperatures–from below 0 °C up until
its crystalline melting point which disappeared after the first cycle
and resolved into a double peak at 123 and 126 °C and minor peaks
at −25 and 19 °C (too small to be visible by eye in this
graph but shown in the Supporting Information). PFAC-8 also displays irreversible melting transitions, with multiple,
broad peaks in the first heating cycle which resolve into a single,
major peak at 70 °C and minor peaks at 19 and −25 °C
after the first heating cycle. This indicates that, having been deposited
below their crystalline melting points, PFAC-8 and -10 are initially
kinetically trapped in a disordered solid state at room temperature.
After the first heating cycle, the equilibrium, reversible phase behavior
emerges. In contrast, PFAC-4 and -6 displayed only reversible melting
transitions in their phase behavior with melting peaks at −19
and 20 °C for both PFAC-6 and -4 and an additional melting peak
at 19 °C for PFAC-4. The commonality of the low intensity peaks
at −25 and 20 °C across all four PFAC-n polymers suggests that these transitions are linked to the polymeric
backbone rather than the side chains. The additional peaks shown at
123 and 126 °C for PFAC-10 and 70 °C for PFAC-8 correspond
to literature values for the melting of the crystallized fluoroalkyl
side chain.[25]
Topography
The
roughness and topography of the polymer
surfaces in air was studied using AFM imaging. Micrographs of PFAC-8
and −10 polymer surfaces are shown in Figure S1.7. The root-mean-square (RMS) roughness values of these
micrographs (each 20 × 20 μm2) are 38 nm (PFAC-8)
and 34 nm (PFAC-10). The phase data for both of these surfaces indicated
full coverage of the underlying glass substrate. Having undergone
a melt below room temperature (Figure ), the softness and smoothness (within the noise level
of the instrument) of the PFAC-4 and -6 surfaces made it impossible
to acquire clear images, even when using a cantilever with an extremely
low spring constant.
Wetting Behavior (Room Temperature)
We next investigated
the advancing and receding contact angles (θadv and
θrec, respectively) of water and dodecane on the
PFAC-n polymer coatings. Figure shows these values along with the difference,
or hysteresis (θhys), between them of water at room
temperature (between 20 and 22 °C). The error bars, which represent
one standard deviation from the mean across 15 measurements (5 measurements
on 3 surfaces), are dominated by the differences between individual
surfaces, rather than the variation between the measurements on a
single surface. The values of θadv for water (top
panel) are similar across the series of PFAC-n polymers.
This implies that a maximum value of θadv has been
reached, which is consistent with the Wenzel wetting regime, which
gives a maximum contact angle of ∼150°.[51,52] The behavior of dodecane, which has lower surface tension, is therefore
more revealing of surface energy trends. For dodecane (bottom panel),
the values of θadv show clear variation across the
series with the maximum at n = 6 and decreasing values
of θadv for shorter and longer chains in the order n = 6 > 4 > 8 > 10. This trend runs contrary to
the literature,
where γ decreases with increasing n.[30] We emphasize at this point
that the large values of θhys for the PFAC-n surfaces, and the roughness of the PFAC-8 and -10 surfaces
as measured via AFM indicate that the surfaces are not ideal (smooth
and chemically homogeneous) with respect to wetting. Any discussion
of surface energy (both γSV and γSL) in this context is therefore a discussion of the effective surface energy: the combined effect of the intrinsic surface energy
of the substance and the effect of roughness or heterogeneity. Similarly,
it may no longer be the case that the measured, static contact angle
is equivalent to the equilibrium contact angle defined by the Young
equation. Henceforth, θ will be used to describe the measured,
static contact angle and the comparison of this value with the equilibrium
contact angle will be discussed on a case-by-case basis. The presence
of CA hysteresis indicates that a surface is heterogeneous but does
not indicate whether that heterogeneity is physical/topographical
or chemical in nature. However, it is striking that PFAC-4 and -6,
which are liquids at room temperature and are therefore smooth, have
larger CA hystereses than PFAC-8 and -10, which are rough. This suggests
a molecular-level or chemical heterogeneity of these surfaces, as
may arise from surface reconstruction induced by the presence of the
liquid droplet on the surface. In this case, surface reconstruction
would mean that the triple-phase line advances across a low energy
fluorocarbon surface but recedes across a higher energy acrylic surface–resulting
in a large contact angle hysteresis.
Figure 4
Advancing (dark) and receding (light)
contact angles of (a) water
and (b) dodecane on PFAC-n surfaces. CA hysteresis (bar) is the difference
between these two values. Error bars represent one standard deviation
from the mean
Advancing (dark) and receding (light)
contact angles of (a) water
and (b) dodecane on PFAC-n surfaces. CA hysteresis (bar) is the difference
between these two values. Error bars represent one standard deviation
from the mean
Contact Angle Aging
With this hypothesis in mind, we
next investigated the possibility of molecular-level reconstruction
of the polymer surfaces driven by interactions at the polymer-fluid
interface. We measured the evolution of the contact angle, θ,
of a sessile drop over time, t, for ethylene glycol
(EG) and hexadecane (HD) on PFAC-n at temperatures
20 ≤ T ≤ 100 (as discussed in the Materials and Methods, it was necessary to exchange
water and dodecane for less volatile liquids). An example plot showing
the variation of the static contact angles, θ, with time, t, of HD on PFAC-6 at different values of T is shown in Figure ; full data may be viewed in the Supporting Information.
Figure 5
Variation of the static contact angles, θ, with time, t, of HD on PFAC-6. The data here is for a single representative
drop at each temperature.
Variation of the static contact angles, θ, with time, t, of HD on PFAC-6. The data here is for a single representative
drop at each temperature.Figure plots the
values of θ for EG (blue) and HD (orange) at t = 1 (dark) and t = 10 (light), which allow the
time-dependent behavior to be more clearly seen. The values shown
are for a single, representative drop at each value of T; averages across all three measurements may be viewed in the Supporting Information. Overall, with the exception
of PFAC-10, time-dependent wetting behavior was observed on all PFAC-n surfaces at some point across the temperature range in
this experiment (20 ≤ T ≤ 100). However,
both the onset and characteristics of this time-dependence vary by
surface. Both EG (polar) and HD (nonpolar) exhibit this behavior,
with similar onset temperatures for both liquids on a given surface
Both PFAC-10 and −8 behave in the same way below their bulk,
crystalline melting points with little or no dependence on t. Once PFAC-8 achieves the liquid state, the values of
θ increase sharply and start to display a dependence on t. For PFAC-6, the values of θ also show no dependence
on t in the low-T regime, a behavior
which persists until T ≈ 40. At T > 40, a dependence on t emerges with the divergence
between the values at t = 1 and t = 10 increasing with increasing T. PFAC-4 follows
the opposite behavior to PFAC-6 in that the values of θ show
a dependence on t in the low-T regime
which then disappears as T increases. For both liquids
on PFAC-4, the values of θ at t = 1 decrease
with increasing T, before starting to plateau as
the values of θ at t = 1 and t = 10 start to converge. An interesting observation is that, examining
the figures for PFAC-6 and −4 side by-side, the wetting behavior
in the high-T regime for PFAC-6 appears to map on
to the low-T regime for PFAC-4. The following paragraphs
will be devoted to providing an explanation for these phenomena.
Figure 6
Values
of θ of ethylene glycol (EG, blue) and hexadecane
(HD, orange) at t = 1 (dark) and t = 10 (light) on (a) PFAC-4, (b) PFAC-6, (c) PFAC-8, and (d) PFAC-10polymer
surfaces. The values are for a single representative drop at each
temperature.
Values
of θ of ethylene glycol (EG, blue) and hexadecane
(HD, orange) at t = 1 (dark) and t = 10 (light) on (a) PFAC-4, (b) PFAC-6, (c) PFAC-8, and (d) PFAC-10polymer
surfaces. The values are for a single representative drop at each
temperature.We will first focus on the effect
of temperature on the surfaces
in the absence of liquid. We have estimated the values of γSV where 20 ≤ T ≤ 100 using
the OWRK method outlined in the introduction. For now, we use the
value of θ at t = 1 as the approximate value
of θ at t = 0 (i.e., before surface rearrangement
or other effects can take place), and the results are shown in Figure . This is a reasonable
assumption where contact angle aging effects are slow or nonexistent
but loses its validity in regimes where aging is rapid.
Figure 7
Total (black)
and polar (red) surface energies of (a) PFAC-4, (b)
PFAC-6, (c) PFAC-8, and (d) PFAC-10 from 20 to 100 °C. These
values were estimated using the OWRK method as outlined in the introduction
and assuming that the contact angles measured at 1 s are a reasonable
substitution for the values at 0 s. The dispersive surface energy
is the difference between the total and polar values.
Total (black)
and polar (red) surface energies of (a) PFAC-4, (b)
PFAC-6, (c) PFAC-8, and (d) PFAC-10 from 20 to 100 °C. These
values were estimated using the OWRK method as outlined in the introduction
and assuming that the contact angles measured at 1 s are a reasonable
substitution for the values at 0 s. The dispersive surface energy
is the difference between the total and polar values.The totals values of γSV range between 6
and 13
mJ m–2 which match the range of values measured
elsewhere of PFAC polymers produced via more conventional means.[53−55] Below their crystalline melting points, the solid surfaces show
a decrease in γSV with increasing T. In the absence of phase transitions, reconstruction, or other adaptations;
the adhesion between the solid surface and probe liquid decreases
as random thermal motion start to dominate. Although it is expected
that solid surface energy will decrease somewhat with temperature,
the decrease in liquid surface energy contributes more strongly to
this trend.[56] This serves as a useful reminder
that the values calculated using the OWRK method are only ever an
estimate of solid surface energy but are nonetheless useful for identifying
trends and making comparisons between surfaces, even if the absolute
values are subject to error PFAC-8 mirrors the properties of PFAC-10
up to its melting point (Tm = 72), at
which point there is a discontinuity and transition to lower value
of γSV.This transition and its likely origin are
interesting, and we map out a likely mechanism in the top and middle
panels of Figure .
The value of Tm as determined by DSC is
the temperature at which the bulk achieves isotropy,
but the segregation of the CF3 groups at the surface is
sufficiently energetically favorable that the surface does not achieve
full isotropy until higher temperatures.[28] Genzer et al. examined a polymer with a C8 perfluorinated side chain
and a bulk melting point of Tm = 70 and
found that the surface had still not achieved isotropy even at 100
°C.[29] Thus, we propose, the initial
drop in γSV of PFAC-8 upon melting is because the
molecules become sufficiently mobile to orient themselves to their
lowest energy configuration (solid disordered, SD, to liquid
ordered, LO, state). Then, as T increases
further, γSV starts to increases again with temperature
as entropic effects begin to dominate and the surface tends toward
isotropy (liquid ordered, LO, to liquid disordered, LD, state); this is a more gradual transition compared to the
sharp solid–liquid melt. A schematic of these three states
are shown in Figure , along with the projected changes in γSV with temperature
for the LO to LD transition. Having undergone
a melt below room temperature, PFAC-4 and -6 already exist on the
continuum between LO and LD, with the longer-chain
PFAC-6 tending toward a more ordered structure. The total values of
γSV for PFAC-4 and −6 measured at t = 1, which are a reasonable approximation of the values
in air, map on to the predicted curve, with PFAC-6 mapping onto the
low-T regime and PFAC-4 mapping onto the high-T regime. However, it must be noted that the measured polar
surface energies, γSVp, change very little with T. At first glance, this would seem to lend itself to the conclusion
that molecular reorientation cannot be responsible for the changes
in γSV because the increased presence of polar acrylate
groups at the surface should necessarily result in γSVp making up an
increased proportion of γSV. However, in this case,
the choice of probe liquids obscures this effect–this will
be discussed in the context of liquid-induced changes to the surface.
Figure 8
(a) Changes
in side chain orientation at the PFAC-n surface across
solid–liquid and liquid–liquid phase
transitions. (b) Changes in γSV of PFAC-n across transition from liquid ordered (LO) to liquid
disordered (LD) phase. (c) Summary of changes in γSL of PFAC-n with time and with temperature.
(a) Changes
in side chain orientation at the PFAC-n surface across
solid–liquid and liquid–liquid phase
transitions. (b) Changes in γSV of PFAC-n across transition from liquid ordered (LO) to liquid
disordered (LD) phase. (c) Summary of changes in γSL of PFAC-n with time and with temperature.Having established evidence for the variation of
PFAC-n contact angles and surface energies with time,
temperature, and n, we now consider the likely underlying
molecular interactions
between the two probe liquids, EG and HD, and the PFAC-n surfaces which drive the effect. In general, the values of θ
for both ethylene glycol (EG) and hexadecane (HD) on PFAC-n surfaces show a dependence on t and T on the whenever the polymer is above its melting point
(T > Tm). The liquid
surfaces can be reasonably assumed to be smooth, and so topographical
effects do not come into play. This is reinforced by the fact that
PFAC-4 and -6 display the largest values of θhys at
room temperature (T ≈ 20) and if this effect
was due to pinning of the triple phase line on physical features,
drop spreading would be inhibited. Contact angle aging effects are
therefore solely a result of chemical changes, or molecular rearrangements,
of the surface and it can be concluded that both polar (EG) and nonpolar
(HD) liquids are able to drive surface reconstruction. In the case
of EG and other polar liquids, this is already well reported in the
literature and is the result of strong polar interactions between
the liquid and the acrylate group.[57−60] The acrylate group migrates to
the surface, lowering the solid–liquid surface energy and resulting
in the drop spreading on the surface. In the case of HD, we propose
that the time dependency of the CAs is the result of the preferential
segregation of the hydrocarbon and fluorocarbon moieties. Fluorocarbon-hydrocarbon
interactions are particularly weak in comparison to hydrocarbon-hydrocarbon
or fluorocarbon-fluorocarbon interactions.[61−63] Segregation
of the two moieties occurs in both liquid and solid systems of semifluorinated
alkanes[64−66] and in copolymer systems containing both fluorocarbon
and hydrocarbon side chains[6760a−68] and it is perhaps a similar effect that drives the
spreading of HD on PFAC-n. This would also account
for the lack of change in the measured values of γSVp across the experimental
temperature range (shown in Figure ). To observe an increase in the measured value of
γSVp,
there needs to be a larger increase in the interactions between the
polar probe liquid and the surface than between the nonpolar probe
liquid and the surface. Because both the dispersive and the polar
probe liquids used in this study trigger surface reconstruction (albeit
for different reasons), this effect is obscured.The bottom
panel of Figure shows
a model outlining how the reconstruction may vary with
time and temperature for polymers above their melting temperature,
consistent with the present measurements. Here, we show the change
in side chain orientation with temperature at t =
0, t = 10, and t = ∞ and
the consequent change in γSL. At t = 0, the configuration of the solid–liquid interface is equivalent
to that in air and so the shape of the curve is simply an inversion
of the curve in the middle panel (as we are now examining solid–liquid
surface energy, γSL, rather than solid–vapor
surface energy, γSV). At t = ∞,
the surface has undergone liquid-induced reconstruction and has relaxed
into its lowest energy state. As with the configuration at t = 0, entropic effects dominate at high temperatures and
the surface tends to isotropy. The stronger solid–liquid interactions
in comparison to solid–vapor interactions mean that this transition
is likely to occur at a higher temperature than in air and it is further
likely that there is a degree of liquid dependency. For simplicity,
we have assumed that the most enthalpically favorable configuration
of the surface in both liquids is with complete inversion of the side
chain. The line at t = 10 indicates the progression
of the solid–liquid interface within the experimental time
frame. In the low-T regime, the surface is kinetically
trapped in its initial configuration and is unable to reconstruct;
the line at t = 10 therefore maps onto the line at t = 0. In the context of our experimental results, this
corresponds to the behavior of PFAC-6 at low temperatures. As T increases and we reach the mid-T region,
molecular mobility increases, and the surface is able to reconstruct.
Initially, the relaxation time is long, and so the surface undergoes
only small changes during the experiment time. As T increases yet further, the relaxation time decreases, and the difference
between t = 10 and t = 0 increases.
This corresponds to the contact angle aging behavior of PFAC-6 at
high temperatures and the behavior of the more mobile PFAC-4 at low
temperatures. Eventually, the surface is able to attain its equilibrium
state within the experimental time frame and the line at t = 10 maps onto the line at t = ∞. In the
context of the experiment, this behavior corresponds to the behavior
of PFAC-4 where the contact angles converge at high temperatures.
Focusing again on the bottom panel of Figure and the high-T region,
the line for t = 10 continues to map onto the curve
for t = ∞ as the surface tends toward isotropy
at which point any time-dependent effects are eliminated.Having
concluded the surface reconstruction is responsible for
the time-dependence of the contact angles of EG and HD and having
discussed the concept of relaxation time in a qualitative sense, the
next section will use Butt’s first order model to investigate
the kinetics of surface reconstruction in a more quantitative fashion.
Kinetics of Surface Reconstruction
Contact angle data
was fitted to eq and
to achieve a good fit, the relaxation time, τ, needs to fall
within the time frame of the experiment, such that 1 ≲ τ
≲ 10. Instances where the value of τ falls outside of
these parameters (whether as a single relaxation process, of part
of multiple relaxation processes) cannot be explored. For PFAC-4,
the data could be fitted for temperatures 40 ≤ T ≤ 80 for EG, and 30 ≤ T ≤
70 for HD. For PFAC-6, the data could be fitted for 80 ≤ T for EG, and 70 ≤ T for HD. None
of the data for PFAC-8 or -10 could be fitted. In all cases, the successful
fits had an adjusted R2 > 0.96 (mostly
>0.98) and χ2 ≤ 6 × 10–5. The complete set of fitted data can be found in the Supporting Information, along with the values
of R2 and χ2.Figure shows the values
of τ for EG and HD on PFAC-4 and −6 at different temperatures.
The results for all three measurements carried out at each temperature
are plotted separately, with the error bars representing the goodness
of fit. In some cases (EG on PFAC-6 at T = 90, HD
on PFAC-6 T = 90, HD on PFAC-4 at T = 70), one of the measured values is significantly different to
the other two; where this occurs, the point is plotted as a filled
circle. The appearance of these outliers suggests that the surfaces
have some degree of inhomogeneity such as the presence of patches
of adsorbed contaminants. As expected, there is a decrease in τ
with increasing T across both liquids on both surfaces
as molecular mobility increases. The curves for both liquids on PFAC-6
are shifted to higher temperatures than PFAC-4 and only overlap at
two points; T = 80 for EG and T =
70 for HD. At both of these points, the value of τ for PFAC-4
is substantially shorter than for PFAC-6; the shift in the curve position
suggests that this is the case across the temperature range studied
and this is as expected for a shorter side chain. Values of τ
for HD are shorter than EG at the same temperature on both surfaces.
There is also a lower onset temperature for curve fitting, which also
suggests that τ is shorter for HD than EG.
Figure 9
Relaxation times, τ,
of (a) EG and (b) HD on PFAC-4 (black)
and -6 (red). Error bars indicate goodness of fit, and where one result
differs substantially from the other two, it is indicated by an unfilled
circle.
Relaxation times, τ,
of (a) EG and (b) HD on PFAC-4 (black)
and -6 (red). Error bars indicate goodness of fit, and where one result
differs substantially from the other two, it is indicated by an unfilled
circle.As discussed in the Introduction, there
are various adaptive processes which can occur at the surface, such
as reconstruction, polymer swelling, or liquid ordering, and the model
does not differentiate between these processes. However, their characteristic
time scales are very different; molecular liquid ordering occurs on
a ns time scale, polymer swelling on a ms time scale, and polymer
reconstruction can occur on anything between the s to day time scale.[68−70] Overall, it seems that the relaxation times measured in this investigation
are associated with reconstruction at the polymer surface. This process
was not found to follow Arrhenius behavior.In addition to determining
the relaxation times of the PFAC-n surfaces, it was
also possible to extrapolate the values
of θ at t = 0 and t = ∞
(θ(0) and θ(∞), respectively). These values for
EG and HD on PFAC-4 and -6 are shown in the Supporting Information. It is interesting to note that the calculated
values of θ(∞) had a very small standard deviation in
comparison with the measured values of θ(0) and despite the
appearance of more than one characteristic value of τ at several
temperatures. This indicates that despite some initial inhomogeneity
in air, the surfaces tend toward homogeneity in liquid.Finally,
the values of ΔγSL were calculated,
defined as the difference between γSL(0) and γSL(∞), and these are plotted in Figure . The results for each measurement is plotted
separately with the error bars indicating goodness of fit. For PFAC-4,
there is a definite difference between EG and HD, with the values
for HD being lower at any given value of T. This
is as expected since EG engages in strong polar interactions with
the surface in comparison with the purely dispersive HD. There is
also a very evident decrease in ΔγSL with increasing T. This is because the configuration of the surface at t = 0 transitions from the side chains being oriented with
CF3 at the surface (low-T regime) to isotropy
(high-T regime). The increased presence of acrylate
groups at the surface in the isotropic configuration is closer in
energy to the configuration at t = ∞ where
all of the acrylate groups are at the surface with CF3 groups
buried. The results for PFAC-6 are less clear-cut, having a larger
scatter and no obvious differentiation between the two liquids. There
does appear to be a general decrease in the values of ΔγSL with T, but it is not pronounced.
Figure 10
Calculated
change in solid–liquid surface energy, ΔγSL, induced by EG (blue) and HD (orange) for (a) PFAC-4 and
(b) PFAC-6. ΔγSL is defined as the difference
between values at t = 0 and t =
∞. Note the different axes
Calculated
change in solid–liquid surface energy, ΔγSL, induced by EG (blue) and HD (orange) for (a) PFAC-4 and
(b) PFAC-6. ΔγSL is defined as the difference
between values at t = 0 and t =
∞. Note the different axesIt is difficult to make a valid comparison between PFAC-4 and -6
since the values of γSL(0) and γSL(∞) behave differently as a function of T; the surface energy of an isotropic surface is dependent on the
stoichiometry of the different functional groups in the polymer and
the temperature at which a surface achieves isotropy is dependent
on the strength of interactions between those functional groups. Having
a longer fluorinated side chain, we would therefore expect isotropic
PFAC-6 to have a higher value of γSL (in this experiment)
and a lower γSV. Stronger interactions between the
side chains give a higher value of T at which the
surface achieves isotropy in comparison to PFAC-4.
Conclusions
The contact angles of ethylene glycol and hexadecane on PFAC-n polymer melts display time dependency, which we conclude
to be the result of surface reconstruction. The driving force for
this reorganization is the polar interactions between ethylene glycol
and the ester group in the polymer, and the stronger dispersive interactions
between hexadecane and the hydrocarbon groups in the polymer. The
latter effect is of particular interest and has not been reported
elsewhere.The first order kinetics model proposed by Butt et
al. is able
to predict the contact angle aging on PFAC-4 and -6 provided that
the relaxation time falls approximately within the experimental time
frame. Outside of this time frame, it is assumed that the model continues
to be valid but cannot conclusively be stated. Likewise, the relaxation
times for PFAC-8 above its melting point of 70 °C longer than
the experimental time frame and cannot be modeled. The relaxation
times in the region where the model is valid are of the order of seconds,
which is consistent with a reorientation process at the solid surface.Our investigation has focused on the commonly used PFAC-n system; nonetheless, there are wide ranging implications
in terms of surface design, in terms of designing both oleo/fluorophobic
surfaces or smart surfaces which rearrange in response to hydrocarbons
or fluorocarbons. The deeper understanding of surface properties of
these PFAC-n surfaces will contribute toward the
development of new oleophilic and smart coatings beyond the most commonly
used PFAC-10, as this is phased out of use for environmental reasons,
including development of nonfluorinated coatings.
Authors: Young Joo Lee; Christopher G Clark; Robert Graf; Manfred Wagner; Klaus Müllen; Hans Wolfgang Spiess Journal: J Phys Chem B Date: 2009-02-05 Impact factor: 2.991