Literature DB >> 35390720

Fiber-integrated WGM optofluidic chip enhanced by microwave photonic analyzer for cardiac biomarker detection with ultra-high resolution.

Panpan Niu1, Junfeng Jiang2, Kun Liu1, Shuang Wang1, Jianying Jing1, Tianhua Xu1, Tong Wang1, Yize Liu1, Tiegen Liu1.   

Abstract

Cardiac troponin I (cTnI) plays an important role in emergency diagnosis of cardiovascular diseases, which exists predominately in the form of cardiac troponin I-C (cTnI-C) complex. We proposed a fiber-integrated optofluidic chip immunosensor with time-delay-dispersion based microwave photonic analyzer (MPA) for cTnI-C detection. The whispering gallery mode (WGM) fiber probe was fabricated by embedding a polydopamine functionalized hollow glass microsphere (HGMS) into the etched capillary-fiber structure, and the WGMs could be excited through the efficient coupling between the thin-wall capillary and the HGMS. The reflective WGM optofluidic chip functioned as a wavelength tuner to construct fiber ring laser cavity, whose laser output wavelength was cTnI-C concentration-dependent. The tiny wavelength variation of sensing laser was converted into a radio-frequency (RF) response, which was retrieved by measuring the change of RF-domain free spectrum range (FSR) in time-delay-dispersion based MPA, and the quantitative detection of cTnI-C complex can be achieved with high resolution. Experimental results show that this immunosensor had a limit of detection (LOD) of 0.59 ng/mL, and a detection resolution of 1.2 fg/mL. The relative resolving power was 102-104-fold higher than that of others optical fiber cTnI biosensors. The proposed fiber-integrated optofluidic chip provides an innovative lab-on-chip diagnostic tool for myocardial damage.
Copyright © 2022 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cardiac troponin; Immunosensor; Microwave photonic filter; Optical fiber; Whispering gallery mode

Mesh:

Substances:

Year:  2022        PMID: 35390720     DOI: 10.1016/j.bios.2022.114238

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  1 in total

1.  Prefab Hollow Glass Microsphere-Based Immunosensor with Liquid Crystal Sensitization for Acute Myocardial Infarction Biomarker Detection.

Authors:  Panpan Niu; Junfeng Jiang; Kun Liu; Shuang Wang; Tianhua Xu; Ziyihui Wang; Tong Wang; Xuezhi Zhang; Zhenyang Ding; Yize Liu; Tiegen Liu
Journal:  Biosensors (Basel)       Date:  2022-06-22
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.