| Literature DB >> 35387902 |
Lei Xu1,2, Ran Li1, Juan Li1,3, Zhou Dong1, Jiaxin Zong1, Chuchu Tan1, Zekang Ye1, Lu Shi1, Xiaoxuan Gong1, Chunjian Li1.
Abstract
Clopidogrel is a pro-drug which needs two-step metabolism to produce the active thiol metabolite. This study aimed to explore an efficient method to simultaneously determine the plasma clopidogrel, 2-oxo-clopidogrel (2-Oxo-CLP), and the clopidogrel active metabolite (CAM). A high-throughput liquid chromatography tandem mass spectrometry (LC-MS/MS) was therefore developed. The analytes were extracted from plasma by using methyl tert-butyl ether (MTBE). Chromatographic separation was performed on a C18 column under an isocratic elution, accompanied with acetonitrile and deionized water containing 0.1% formic acid. After optimizing the condition of LC-MS/MS, a stable linearity was observed in the standard curves over the concentration ranges of 0.05 to 50.0 ng/mL for clopidogrel, 0.5 to 50.0 ng/mL for 2-Oxo-CLP, and 0.5 to 100 ng/mL for clopidogrel active metabolite derivative (CAMD). The retention time was 4.78 minutes, 3.79 minutes, 3.59 minutes, and 4.82 minutes for clopidogrel, 2-Oxo-CLP, CAMD, and internal standard, respectively. Both the relative standard deviation and the relative error were within the requirement of operating criteria. No significant degradation of clopidogrel, 2-Oxo-CLP, and CAMD occurred under different storage conditions. This method was successfully validated in 3 patients with coronary artery disease. The results showed that the current LC-MS/MS method was efficient for simultaneously detecting clopidogrel, 2-Oxo-CLP, and CAM with fine linearity, accuracy, precision, and stability.Entities:
Keywords: clopidogrel; coronary artery disease; drug metabolites; liquid chromatography tandem mass spectrometry
Year: 2022 PMID: 35387902 PMCID: PMC9002156 DOI: 10.7555/JBR.36.20210125
Source DB: PubMed Journal: J Biomed Res ISSN: 1674-8301
Optimized mass spectrometer parameters
| Analytes | Precursor
| Fragment
| Cone voltage
| Collision
|
| 2-Oxo-CLP: 2-oxo-clopidogrel; CAMD: clopidogrel active metabolite derivative; IS: internal standard.
| ||||
| Clopidogrel | 322.0 | 212.0 | 22 | 15 |
| 2-Oxo-CLP | 338.0 | 183.0 | 24 | 17 |
| CAMD | 504.0 | 354.0 | 27 | 19 |
| IS | 430.0 | 372.0 | 28 | 21 |
Recovery and matrix effect for clopidogrel, 2-Oxo-CLP and CAMD without DTT
| Analytes | Concentration (ng/mL) | Recovery | Matrix effect | |||
| (%) | RSD (%) | (%) | RSD(%) | |||
| All the data are presented as mean±SD. 2-Oxo-CLP: 2-oxo-clopidogrel; CAMD: clopidogrel active metabolite derivative; DTT: 1, 4-Dithio-DL-threitol; RSD: relative standard deviation. | ||||||
| Clopidogrel | 0.1 | 101.9±8.3 | 8.1 | 76.7±2.3 | 3.0 | |
| 40 | 81.5±12.0 | 14.7 | 75.8±10.0 | 13.2 | ||
| 2-Oxo-CLP | 1 | 70.2±22.1 | 31.5 | 74.6±9.7 | 13.0 | |
| 40 | 62.4±6.1 | 9.7 | 60.3±0.5 | 0.9 | ||
| CAMD | 1 | 72.2±26.9 | 37.2 | 75.1±9.7 | 12.9 | |
| 80 | 82.4±15.2 | 18.4 | 69.8±2.2 | 3.1 | ||
Impacts of concentrations of HCl on extraction efficiencies and matrix effects of the three analytes
| Concentration
| 0.01 mol/L HCl | 0.05 mol/L HCl | 0.1 mol/L HCl | ||||||
| Extraction
| Matrix
| Extraction
| Matrix
| Extraction
| Matrix
| ||||
| All the data were presented as mean±SD. 2-Oxo-CLP: 2-oxo-clopidogrel; CAMD: clopidogrel active metabolite derivative. | |||||||||
| Clopidogrel
| 0.1 | 170.9±8.9 | 364.0±10.2 | 107.4±6.2 | 75.0±2.8 | 194.4±9.8 | 52.9±2.9 | ||
| 20 | 147.5±6.1 | 107.4±4.5 | 116.5±2.2 | 94.1±10.0 | 155.7±7.4 | 52.1±4.0 | |||
| 40 | 138.8±5.4 | 88.2±4.3 | 118.7±8.7 | 71.9±5.9 | 134.0±6.1 | 49.0±3.1 | |||
| 2-Oxo-CLP
| 1 | 96.5±6.4 | 72.1±4.3 | 92.5±3.9 | 63.7±3.4 | 115.1±9.5 | 40.5±3.6 | ||
| 20 | 103.2±3.4 | 61.3±4.0 | 117.0±3.5 | 71.6±5.0 | 148.3±6.5 | 38.2±3.1 | |||
| 40 | 103.9±3.2 | 64.5±4.3 | 110.9±7.8 | 63.7±4.6 | 133.7±3.5 | 39.5±2.0 | |||
| CAMD | 1 | 32.1±2.3 | 84.0±2.5 | 96.7±3.2 | 70.8 ±5.3 | 93.4±13.3 | 52.2±6.3 | ||
| 40 | 34.8±1.6 | 80.7±3.8 | 123.4±3.9 | 53.0±5.8 | 171.6±5.3 | 39.7±2.1 | |||
| 80 | 34.0±2.6 | 88.4±2.3 | 120.2±7.0 | 59.3±5.0 | 167.9±5.1 | 53.8±4.6 | |||
Calibration curve equations for clopidogrel, 2-Oxo-CLP, and CAMD
| Compound (ng/mL) | Calibration curve equations | Correlation coefficient ( |
| 2-Oxo-CLP: 2-oxo-clopidogrel; CAMD: clopidogrel active metabolite derivative. | ||
| Clopidogrel (0.05–50.0) | Pclopidogrel/PIS=0.08147× | 0.9984 |
| 2-Oxo-CLP (0.5–50.0) | P2-OXO-CLP/PIS=0.009094× | 0.9974 |
| CAMD (0.5–100.0) | PCAMD/PIS=0.01072× | 0.9979 |
Intra-day and inter-day precision and accuracy for clopidogrel, 2-Oxo-CLP, and CAMD
| Analyte | Nominal concentration (ng/mL) | Intra-day ( | Inter-day ( | |||||
| Mean assayed value (ng/mL) | Accuracy
| Precision
| Mean assayed value (ng/mL) | Accuracy
| Precision
| |||
| 2-Oxo-CLP: 2-oxo-clopidogrel; CAMD: clopidogrel active metabolite derivative; RE: relative error, RE=(nominal sample concentration–tested sample concentration)/nominal sample concentration×100%; RSD: relative standard deviation, RSD=SD value/mean value×100%. | ||||||||
| Clopidogrel | 0.1 | 0.1 | 15.2 | 4.8 | 0.1 | 12.2 | 18.7 | |
| 20 | 20.7 | 3.6 | 2.2 | 20.4 | 2.0 | 3.7 | ||
| 40 | 41.8 | 4.5 | 2.7 | 42.4 | 5.9 | 5.6 | ||
| 2-Oxo-CLP | 1 | 1.1 | 5.8 | 4.7 | 1.0 | 2.8 | 19.2 | |
| 20 | 21.2 | 5.8 | 4.0 | 20.6 | 2.9 | 6.4 | ||
| 40 | 41.0 | 2.7 | 5.8 | 42.4 | 6.0 | 7.7 | ||
| CAMD | 1 | 1.0 | 2.8 | 8.5 | 1.0 | 4.0 | 14.8 | |
| 40 | 42.0 | 5.0 | 4.3 | 42.0 | 5.1 | 8.8 | ||
| 80 | 83.0 | 3.7 | 7.2 | 84.6 | 5.8 | 5.9 | ||
Stability of clopidogrel, 2-Oxo-CLP, and CAMD in human plasma
| Analytes | Added (ng/mL) | Found (ng/mL) | ||||
| At –80 °C
| After
| Plasma at room
| Extract at room
| Extract in the
| ||
| All the data are presented as mean±SD. 2-Oxo-CLP: 2-oxo-clopidogrel; CAMD: clopidogrel active metabolite derivative. | ||||||
| Clopidogrel | 0.2 | 0.2±0.0 | 0.2±0.0 | 0.2±0.0 | 0.2±0.0 | 0.2±0.0 |
| 10 | 10.1±0.2 | 10.1±0.8 | 10.4±0.8 | 10.0±1.4 | 10.0±0.8 | |
| 2-Oxo-CLP | 2 | 2.0±0.1 | 1.9±0.2 | 2.2±0.4 | 2.1±0.2 | 2.2±0.2 |
| 50 | 50.6±1.2 | 51.0 ± 3.9 | 52.2±5.1 | 50.1±7.6 | 49.0±3.7 | |
| CAMD | 2 | 2.0±0.1 | 1.9 ± 0.2 | 2.2±0.4 | 2.0±0.2 | 2.1±0.2 |
| 50 | 50.4±1.2 | 51.5±3.8 | 51.1±4.9 | 49.6±7.7 | 50.1±3.9 | |