Literature DB >> 353852

Distant migration of silicone gel from a ruptured breast implant. Case report.

A Capozzi, R Du Bou, V R Pennisi.   

Abstract

A complication of augmentation mammaplasty is presented in which the bag of a gel-filled implant ruptured and the thin gel migrated through subcutaneous planes as far as the groin. We feel that when a rupture of a gel-filled prosthesis becomes evident, it should be replaced as soon as possible if such migration is to be prevented (particularly if the gel is of the thinner and less-cohesive variety).

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 353852     DOI: 10.1097/00006534-197808000-00038

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  10 in total

1.  Breast prothesis leakage and malignant changes of the breast.

Authors:  Taha Al-Lawati; Rajyashree Kutty
Journal:  Oman Med J       Date:  2009-04

2.  Experiences with inflatable implants.

Authors:  P S Striker
Journal:  Aesthetic Plast Surg       Date:  1979-12       Impact factor: 2.326

3.  Silicone fluid, attractive and dangerous: Collective review and summary of experience.

Authors:  F U Piechotta
Journal:  Aesthetic Plast Surg       Date:  1979-12       Impact factor: 2.326

Review 4.  Pathology of silicone leakage from breast implants.

Authors:  P J van Diest; W H Beekman; J J Hage
Journal:  J Clin Pathol       Date:  1998-07       Impact factor: 3.411

Review 5.  An association of silicone-gel breast implant rupture and fibromyalgia.

Authors:  S Lori Brown; Hesha Jani Duggirala; Gene Pennello
Journal:  Curr Rheumatol Rep       Date:  2002-08       Impact factor: 4.592

Review 6.  The immunopathology of siliconosis. History, clinical presentation, and relation to silicosis and the chemistry of silicon and silicone.

Authors:  D R Shanklin; D L Smalley
Journal:  Immunol Res       Date:  1998       Impact factor: 2.829

7.  Radiological pitfall: Siliconoma in internal mammary lymph node mimics breast cancer recurrence.

Authors:  Karen Steinke; Phillipa Brook; Olivier Ramuz
Journal:  Radiol Case Rep       Date:  2015-11-06

8.  Distant Migration of Multiple Siliconomas in Lower Extremities following Breast Implant Rupture: Case Report.

Authors:  Joo Hyun Oh; Seung Yong Song; Dae Hyun Lew; Dong Won Lee
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-10-27

9.  Skin deep: Cutaneous manifestation of PIP implant rupture.

Authors:  Máire-Caitlín Casey; Edward Jason Kelly
Journal:  JPRAS Open       Date:  2021-03-19

10.  Silicone Migration and Late Hematoma following Silicone Implant Rupture: Case Report and Literature Review.

Authors:  Riley A Dean; Adam D Glener; Analise B Thomas; Steven R Glener; Silvia Kurtovic; Detlev Erdmann
Journal:  Plast Reconstr Surg Glob Open       Date:  2018-08-06
  10 in total