Yucui Hou1, Qi Zhang2,3, Minjie Gao2, Shuhang Ren2, Weize Wu2. 1. Department of Chemistry, Taiyuan Normal University, No. 319 Daxue Street, Yuci District, Jinzhong, Shanxi 030619, China. 2. State Key Laboratory of Chemical Resource Engineering, Beijing University of Chemical Technology, No. 15 Beisanhuan East Road, Chaoyang District, Beijing, 100029, China. 3. SEDIN Engineering Co., Ltd. CNCEC, No. 1 Saiding Road, Jinyang Street, Xuefu District, Taiyuan, Shanxi 030032, China.
Abstract
The absorption of SO2 from flue gas and its conversion to chemicals is important in the industry. Functional ionic liquids (ILs) have been broadly used to absorb SO2 in flue gas, but seldom convert it to chemicals. As we know, water is inevitable in a desulfurization process. In this work, three functional ILs (monoethanolaminium lactate-[MEA][Lac], 1,1,3,3-tetramethylguanidinium lactate-[TMG][Lac], tetraethylammonium lactate-[N2222][Lac]) with or without water were used as absorbents to absorb SO2 in flue gas, and then the absorbed SO2 in the absorbents was converted to sulfur via a Claus reaction. The result shows that the three ILs can efficiently absorb SO2 and convert it to sulfur. But the addition of water in the ILs can reduce the conversion of absorbed SO2, and the conversion increases with increasing the acidity of absorbents. To explain this phenomenon, we studied the Claus reaction in H2SO3, NaHSO3 and Na2SO3 aqueous solutions. It turns out that the conversion of the Claus reaction is related to the species of S (IV) in the order of the oxidability: H2SO3 > HSO3 - > SO3 2-, and their proportions dependent on the pH of solutions. On the basis of the absorption mechanism of SO2 in functional ILs aqueous solution, H2S reacts with HSO3 - and SO3 2- with weaker oxidability, resulting in the lower conversion. Importantly, we found that the addition of lactic acid could increase the conversion of SO2 via the Claus reaction.
The absorption of SO2 from flue gas and its conversion to chemicals is important in the industry. Functional ionic liquids (ILs) have been broadly used to absorb SO2 in flue gas, but seldom convert it to chemicals. As we know, water is inevitable in a desulfurization process. In this work, three functional ILs (monoethanolaminium lactate-[MEA][Lac], 1,1,3,3-tetramethylguanidinium lactate-[TMG][Lac], tetraethylammonium lactate-[N2222][Lac]) with or without water were used as absorbents to absorb SO2 in flue gas, and then the absorbed SO2 in the absorbents was converted to sulfur via a Claus reaction. The result shows that the three ILs can efficiently absorb SO2 and convert it to sulfur. But the addition of water in the ILs can reduce the conversion of absorbed SO2, and the conversion increases with increasing the acidity of absorbents. To explain this phenomenon, we studied the Claus reaction in H2SO3, NaHSO3 and Na2SO3 aqueous solutions. It turns out that the conversion of the Claus reaction is related to the species of S (IV) in the order of the oxidability: H2SO3 > HSO3 - > SO3 2-, and their proportions dependent on the pH of solutions. On the basis of the absorption mechanism of SO2 in functional ILs aqueous solution, H2S reacts with HSO3 - and SO3 2- with weaker oxidability, resulting in the lower conversion. Importantly, we found that the addition of lactic acid could increase the conversion of SO2 via the Claus reaction.
The emission of sulfur
dioxide (SO2), which is mainly
emitted from burning of coal, brings harm to not only the human body
but also environmental safety.[1,2] Traditional flue gas
desulfurization technologies, for example, limestone scrubbing, are
deficient in absorbents regeneration and SO2 utilization.[3−5] Ionic liquids (ILs), which have many superior properties, have been
widely studied in gas separation.[6−11] Besides, ILs are promising reaction mediums because of their inherent
catalytic reactivity for numerous reactions.[12−14] Among them,
functional ILs with some special groups can chemically absorb SO2 so that SO2 with low concentrations (like 0.2
vol %) in flue gas can be removed efficiently.[15−21] Wang et al. summarized the solubility of low-concentration SO2 in various functional ILs.[22] However,
the chemical interactions between SO2 and functional ILs
are quite strong, which make it difficult to be regenerated. Therefore,
the desorption of SO2 from functional ILs by high temperature
treatment usually needs high energy consumption.[23] Moreover, high temperature treatment also causes decreasing
stability of absorbents and increasing difficulty of separation. Huang
et al.[24] performed good work to use various
common ILs as the solvents for the Claus reaction, which could achieve
a conversion rate up to 99% at 40 °C. However, more commonly
studied ILs can absorb SO2 with high solubility at high
SO2 concentrations only by physical interaction. To change
the traditional method, our research group put forward a new method
to regenerate functional ILs by using the Claus reaction and achieved
good results.[25] The result shows that the
SO2-absorbed functional ILs can be regenerated efficiently
under a mild condition, and then SO2 from flue gas can
be converted to sulfur for the comprehensive utilization. After several
absorption and regeneration cycles, the absorbents still have high
absorption capacity of SO2 and the conversion of SO2 via the Claus reaction does not decrease significantly. This
new regeneration method is easy to operate and shows a good prospect
in application.In the previous work,[25] it has been
found that H2O has an effect on the liquid-phase Claus
reaction. For monoethanolaminium lactate ([MEA][Lac]) used as
an absorbent, the addition of H2O can reduce the conversion
of absorbed SO2 via the Claus reaction, which is unfavorable
to the regeneration process. However, no matter in the absorption
or desorption processes, H2O is an important component.
There is about 7 vol % H2O in flue gas at 40 °C, so
absorbents contain a certain amount of water.[26] In the Claus reaction, H2O is a product of the reaction.
H2O is inevitable and always used as an environmentally
friendly solvent in ILs to adjust the viscosity of absorbents. Therefore,
it is very necessary to study the effect of water on the Claus reaction
and explore the mechanism of the Claus reaction in aqueous solutions.In this study, we used three common functional ILs ([MEA][Lac],
1,1,3,3-tetramethylguanidinium lactate-[TMG][Lac], tetraethylammonium
lactate-[N2222][Lac], the structures of which are shown
in Scheme ) mixed
with H2O to prepare the absorbents. After absorbing low-concentration
SO2, the absorbents were regenerated by using H2S via the Claus reaction. The effect of H2O on the conversion
of absorbed SO2 was investigated. To explore the mechanism
of the Claus reaction in aqueous solutions more intuitively, we took
H2SO3, NaHSO3, and Na2SO3 as examples to analyze whether the existence of S
(IV) would affect the conversion of absorbed SO2 via the
Claus reaction. After giving a supposition, we further explored the
influence of existence of S (IV) to clarify the mechanism of the Claus
reaction in the presence of water.
Scheme 1
Chemical Structures of [MEA][Lac],
[TMG][Lac], and [N2222][Lac]
Results and Discussion
Absorption Reaction and
Claus Reaction in
Three Functional ILs and H2O Binary Systems
Three
functional ILs ([MEA][Lac], [TMG][Lac], [N2222][Lac]) mixed
with H2O were used as absorbents (mIL:mH2O = 1:1). And the absorption
capacities of the three absorbents at 40.0 °C are shown in Table . It can be seen that
the results are consistent with the previous work. For instance, the
absorption capacity by [TMG][Lac] is 0.51 mol SO2/mol IL
at a SO2 concentration of 2% and a water content of 7.3%
in simulated flow gas.[26] The absorption
capacity by [N2222][Lac] is 0.791 mol SO2/mol
IL with 3 vol % SO2 in flue gas at 60.0 °C.[27]
Table 1
SO2 Absorption
Capacity
in the Three Functional ILs Aqueous Solutions
Absorption conditions:
temperature,
40.0 °C; SO2 concentration, 2.0%.According to ref (28), the absorption mechanism
of SO2 in these functional
ILs is that SO2 is absorbed physically and chemically.
The physical absorption follows Henry’s law. The chemical absorption,
taking [N2222][Lac] as an example, follows the reaction
as shown in eq :[29]It can be seen from Table that the absorption
of SO2 does not reach the stoichiometric ratios because
of the low chemical equilibrium constant and the low concentration
of SO2.After that, we used the Claus reaction to
regenerate the SO2-absorbed functional ILs aqueous solution
by H2S. At 40.0 °C, the pressure of H2S
in the chamber
as a function of time in the three absorbents are shown in Figure a. Ethylene glycol
(EG) is a nonaqueous solvent, and it is different from water as a
solvent. Therefore, EG was used as a solvent for comparison with water.
It is obvious that the reaction rate in aqueous solutions (Figure a) is slower than
that in an EG solution[25] (Figure b). Hence, the reaction in
aqueous solutions needs a longer time to reach the equilibrium.
Figure 1
Pressures of
H2S as a function of time for the Claus
reaction at 40.0 °C in different absorbents. (a) Black square,
50% [MEA][Lac] + 50% H2O; blue circle, 50% [TMG][Lac] +
50% H2O; red triangle, 50% [N2222][Lac] + 50%
H2O. (b) Black square, 50% [MEA][Lac] + 50% EG; blue circle,
50% [TMG][Lac] + 50% EG; red triangle, 50% [N2222][Lac]
+ 50% EG. (b) is adapted with permission from ref (25). Copyright 2019 American
Chemical Society.
Pressures of
H2S as a function of time for the Claus
reaction at 40.0 °C in different absorbents. (a) Black square,
50% [MEA][Lac] + 50% H2O; blue circle, 50% [TMG][Lac] +
50% H2O; red triangle, 50% [N2222][Lac] + 50%
H2O. (b) Black square, 50% [MEA][Lac] + 50% EG; blue circle,
50% [TMG][Lac] + 50% EG; red triangle, 50% [N2222][Lac]
+ 50% EG. (b) is adapted with permission from ref (25). Copyright 2019 American
Chemical Society.The conversions of SO2 absorbed in the three absorbents
via the Claus reaction are shown in Table . Moreover, we compared the conversion rate
of SO2 in the three systems, and there was a significant
decline in an aqueous solution compared with those in pure ILs and
EG solutions. However, compared with EG as the solvent, the dissolution
phenomenon of sulfur in aqueous absorbents was very low, and the resulted
sulfur could be separated easily by centrifugation and filtration.
One possible reason might be the very low solubility of sulfur in
aqueous solutions, inhibiting the sulfur dissolution in absorbents
to a certain extent.
Table 2
Recovery Ratios of
Sulfur in the Three
Functional ILs with Different Solventsa
RS
ILs
pure ILs
mIL:mEG = 1:1
mIL:mH2O = 1:1
[MEA][Lac]
95.4 ± 1.2
96.4 ± 1.1
72.4 ± 1.2
[TMG][Lac]
92.5 ± 1.1
91.8 ± 1.1
85.7 ± 1.1
[N2222][Lac]
91.2 ± 1.0
90.3 ± 1.2
78.7 ± 1.2
The conditions
of the Claus reaction:
temperature, 40.0 °C; initial pressure of H2S, 1.1
MPa.
The conditions
of the Claus reaction:
temperature, 40.0 °C; initial pressure of H2S, 1.1
MPa.
Effect
of Temperature and H2O Mass
Fraction on the Claus Reaction
Taking the [MEA][Lac] aqueous
solution as an example, we studied the effect of temperature and H2O mass fraction on the Claus reaction. The conversions of
SO2 in [MEA][Lac] + H2O (m[MEA][Lac]:mH2O = 1:1) at 40.0,
50.0, and 60.0 °C are shown in Table . As can be seen from Table , the conversion decreases as the temperature
increases, which is consistent with those in ILs and EG binary systems.[25] The results demonstrated that the low temperatures
would be beneficial to the liquid-phase Claus reaction. This result
can satisfy the desired requirement of using the Claus reaction to
regenerate functional ILs, that is, the temperatures of absorption
and regeneration are identical, saving energy.
Table 3
Recovery Ratios of Sulfur in [MEA][Lac]
+ H2O (m[MEA][Lac]:mH2O = 1:1) at Different Temperatures
entry
IL
solvent
T/°C
PH2S/MPa
RS/%
1
[MEA][Lac]
H2O
40.0
1.10
72.4 ± 1.2
2
[MEA][Lac]
H2O
50.0
1.10
70.6 ± 1.1
3
[MEA][Lac]
H2O
60.0
1.10
69.2 ± 1.0
In our previous work, the mass fraction of EG had no obvious influence
on the conversion of SO2 via the Claus reaction. To investigate
whether the content of water has an effect on the conversion, we changed
the mass fraction of H2O in the absorbents to do a series
of experiments. Table shows the conversion of SO2 using the Claus reaction
in [MEA][Lac] aqueous solutions with different water contents. According
to the results in Table , as water contents increased, the conversion decreased. As reported
in the literature,[29,30] the chemical equation of the
Claus reaction is shown in eq . Therefore, a possible reason might be that the Claus reaction
can generate water, and the increase of water content can move the
reverse direction of the reversible chemical reaction:
Table 4
Recovery
Ratios of Sulfur in [MEA][Lac]
+ H2O with Different Mass Fractions of H2O
entry
IL
solvent (mass
fraction)
T/°C
PH2S/MPa
RS/%
1
[MEA][Lac]
40.0
1.10
95.4 ± 1.2
2
[MEA][Lac]
H2O (25%)
40.0
1.10
86.8 ± 1.1
3
[MEA][Lac]
H2O (50%)
40.0
1.10
72.4 ± 1.2
Study on the Claus Reaction in H2SO3, NaHSO3, and Na2SO3 Aqueous
Solutions
In the previous subsections, it can be
found that the addition of water can reduce the conversion of SO2 in functional ILs aqueous solution via the Claus reaction.
However, water is inevitable in industrial application, and it has
a certain influence on the absorption and regeneration stages of functional
ILs. As is known, the absorbed SO2 in functional ILs aqueous
solution mainly exists as H2SO3, HSO3–, and SO32–. Actually,
in the liquid-phase Claus reaction, the three species of S (IV) react
with H2S, as shown in eq :To study the effect of water
on the Claus reaction, we used H2SO3, NaHSO3, and Na2SO3 aqueous solutions to study
the mechanism of the Claus reaction.The concentration of S
(IV) in three aqueous solution is 1.0 mol/L, and the experimental
method is the same as that in functional ILs. The conversion was calculated
by the ratio of the generated sulfur to the theoretical sulfur. Table shows the conversion
of SO2 via the Claus reaction at 40.0 °C. It is very
interesting that the conversions have great differences at the same
concentrations of S (IV). It should be noted that the conversion is
almost zero in the Na2SO3 aqueous solution.
We found that the oxidability of three chemical substances varied
from pH values of aqueous solutions, and the oxidability order is
H2SO3 (SO2) > HSO3– > SO32–, which is
in
consistence with their standard reduction potentials, 0.45 V, −0.19
V, and −0.90 V, respectively (data were obtained from the refs (31 and 32) and calculated according to the
thermodynamics law). The Claus reaction is a redox reaction and the
conversion of S (IV) species is directly affected by its oxidability.
Therefore, due to its low oxidability, SO32– cannot react with H2S, resulting in its low conversion.
Table 5
Recovery Ratios of Sulfur in H2SO3, NaHSO3, and Na2SO3 Aqueous Solutionsa
entry
aqueous solution
concentration
of S species (based on SO2)/mol/L
RS/%
1
H2SO3
1.0
78.6 ± 1.1
2
NaHSO3
1.0
37.3 ± 1.0
3
Na2SO3
1.0
0
The conditions of the Claus reactions:
the total concentration of H2SO3, NaHSO3, and Na2SO3, 1 mol/L, initial pressure
of H2S, 1.1 MPa, temperature, 40.0 °C.
The conditions of the Claus reactions:
the total concentration of H2SO3, NaHSO3, and Na2SO3, 1 mol/L, initial pressure
of H2S, 1.1 MPa, temperature, 40.0 °C.As is known, there is an ionization
equilibrium in H2SO3, HSO3–, and SO32– aqueous solution, and the
pH of the solution
is the determining factor. Table shows the mole fractions of H2SO3, HSO3–, and SO32– at different pH, which were calculated by ionization and hydrolysis
equilibrium constant.
Table 6
Mole Fractions of
H2SO3, HSO3–, and
SO32– at Different pH in Aqueous Solution
at 25 °C
pHa
δ(H2SO3)/%
δ(HSO3–)/%
δ(SO32–)/%
1
87.0
13.0
0
2
40.0
60.0
0
3
6.3
93.7
0
4
0.7
99.2
0.1
5
0.1
98.9
1.0
6
0
90.9
9.1
7
0
50.0
50.0
8
0
9.1
90.9
The pH values of
aqueous solutions
were adjusted by HCl and NaOH. The total concentration of H2SO3, HSO3–, and SO32– is 1 mol/L, and the initial pressure of H2S is 1.1 MPa.
The pH values of
aqueous solutions
were adjusted by HCl and NaOH. The total concentration of H2SO3, HSO3–, and SO32– is 1 mol/L, and the initial pressure of H2S is 1.1 MPa.As
can be seen in Table , the mole fraction of H2SO3 decreases
as the pH increases or the acidity decreases. When pH value of the
aqueous solution is 1, the mole fraction of H2SO3 is 87.0%; when pH value of the aqueous solution is 6 and higher,
there is no H2SO3. By the contract, the mole
fraction of HSO3– first increases and
then decreases as the pH increases or the acidity decreases. The mole
fraction of HSO3– is 13.0% at a pH value
of 1, and it increases to a maximum value of 99.2% at a pH value of
4 and decreases to 9.1% at a pH value of 8. Moreover, S (IV) mainly
exists in the form of HSO3– with mole
fractions more than 90% between 3 and 6 of the pH values. Thus, we
took the NaHSO3 aqueous solution as an example to study
the effect of pH on the Claus reaction. Table shows the pH value of the NaHSO3 aqueous solution before and after the Claus reaction and its recovery
ratio of sulfur at 40.0 °C.
Table 7
pH Value of NaHSO3 Aqueous
Solution before and after the Claus Reaction and Its Recovery Ratio
of Sulfura
entry
pH (before
the Claus reaction)
pH (after
the Claus reaction)
RS/%
1
2.12
7.02
49.9 ± 1.0
2
3.52
7.21
37.3 ± 1.2
3
5.05
7.96
34.8 ± 1.1
4
5.95
7.82
19.7 ± 1.0
5
7.07
7.34
0.2 ± 1.1
The conditions
of the Claus reaction:
the concentration of NaHSO3, 1 mol/L; initial pressure
of H2S, 1.1 MPa; the temperature, 40.0 °C.
The conditions
of the Claus reaction:
the concentration of NaHSO3, 1 mol/L; initial pressure
of H2S, 1.1 MPa; the temperature, 40.0 °C.As can be seen in Table , the pH values after the reaction
are between 7 and 8 no
matter the pH value before the Claus reaction. As the pH value before
the Claus reaction increases from 2.12 to 7.07, the recovery ratio
of sulfur decreases from 49.9% to 0.2%. Two conclusions can be drawn
from Table . The first
one is that the Claus reaction is accompanied by the consumption of
H2SO3 and HSO3–, and then the content of SO32– increases
after the Claus reaction. Hence, the acidity of the solution decreases
as the pH values are between 7.02 and 7.96. The second one is that
the stronger the acidity of the solution, the higher the conversion
of SO2 via the Claus reaction as the recovery ratio of
sulfur is the highest at the lowest pH value of 2.12, which indicates
that an acidic aqueous solution is more beneficial to the Claus reaction.
Effect of pH of Absorbents on the Claus Reaction
According to the above results, it can be found that the pH of
the aqueous solution can affect the species of S (IV), which can then
further affect the conversion rate of the Claus reaction. Whether
the conclusions are applicable to the functional ILs, aqueous solution
needs further experimental exploration.First of all, we investigated
the effect of the H2SO4 on the pH of [TMG][Lac]
aqueous solution (w[TMG][Lac) = 60%),
SO2 absorption capacity, and the conversion of SO2 via the Claus reaction. Table shows the absorption capacity of SO2 (2
vol %) and the conversion of SO2 via the Claus reaction
at 40.0 °C. It can be concluded from Table that the conversion increases with the pH
value decrease. However, there are two points to which attention should
be paid. First, with the increase of H2SO4 content
above 2%, the conversion increases to about 91% and remains unchanged.
Second, the change of the pH of the absorbents by adding H2SO4 can improve the conversion of SO2 via the
Claus reaction but also reduce the absorption capacity of SO2. Therefore, it is necessary to increase the conversion by adding
an acid in a proper range.
Table 8
Effect of Amount
of Added H2SO4 on SO2 Absorption
and the Claus Reaction
in [TMG][Lac] Aqueous Solutiona
w (H2SO4)
pHabs
absorption
capacity (g SO2/g abs)
RS/%
0
8.20
0.120
86.1 ± 1.0
2%
5.85
0.101
91.2 ± 1.0
4%
5.37
0.086
91.4 ± 1.1
6%
5.00
0.074
91.2 ± 1.2
8%
4.59
0.055
91.6 ± 1.0
10%
4.29
0.039
91.1 ± 1.1
The concentration
of [TMG][Lac]
in aqueous solutions is 60 wt % (w[TMG][Lac] = 60%), the concentration of SO2 is 2 vol %, the temperature
of SO2 absorption of is 40 °C, and the temperature
of the Claus reaction is 40 °C.
The concentration
of [TMG][Lac]
in aqueous solutions is 60 wt % (w[TMG][Lac] = 60%), the concentration of SO2 is 2 vol %, the temperature
of SO2 absorption of is 40 °C, and the temperature
of the Claus reaction is 40 °C.However, H2SO4 is a kind of
inorganic strong
acid, and it has some interference to the system; thus, we used lactic
acid to adjust the acidity of absorbents. Specifically, the functional
ILs were synthesized with different mole ratios of MEA (or TMG) and
lactic acid. SO2 absorption capacity and recovery ratios
of the Claus reaction in [MEA][Lac] and [TMG][Lac] aqueous solutions
with different amounts of added lactic acid are shown in Tables and 10. The concentration of SO2 was 2 vol %, and the
temperatures of SO2 absorption and the Claus reaction were
both 40.0 °C.
Table 9
Effect of nHLac:n[MEA][Lac] on SO2 Absorption
and the Claus Reaction in [MEA][Lac] Aqueous Solutiona
nHLa:n[MEA][Lac]
absorption
capacity (g SO2/g abs)
RS/%
0:1
0.067
72.4 ± 1.1
0.1:1
0.053
75.3 ± 1.0
0.2:1
0.050
77.2 ± 1.2
0.3:1
0.040
78.0 ± 1.0
0.4:1
0.035
81.2 ± 1.1
The concentration
of [MEA][Lac]
in aqueous solutions is 50 wt %, the concentration of SO2 is 2 vol %, the temperature of SO2 absorption is 40 °C,
and the temperature of the Claus reaction is 40 °C.
Table 10
Effect of nHLac:n[TMG][Lac] on SO2 Absorption and the Claus Reaction in [TMG][Lac]
Aqueous Solutiona
nHLac:n[TMG][Lac]
absorption
capacity (g SO2/g abs)
RS/%
0:1
0.089
85.7
0.05:1
0.081
85.7
0.1:1
0.078
85.7
0.2:1
0.073
87.3
0.3:1
0.069
88.1
The concentration of [TMG][Lac]
in aqueous solutions is 50 wt %, the concentration of SO2 is 2 vol %, the temperature of SO2 absorption is 40.0
°C, and the temperature of the Claus reaction is 40.0 °C.
The concentration
of [MEA][Lac]
in aqueous solutions is 50 wt %, the concentration of SO2 is 2 vol %, the temperature of SO2 absorption is 40 °C,
and the temperature of the Claus reaction is 40 °C.The concentration of [TMG][Lac]
in aqueous solutions is 50 wt %, the concentration of SO2 is 2 vol %, the temperature of SO2 absorption is 40.0
°C, and the temperature of the Claus reaction is 40.0 °C.Through the exploration of
effect of pH on the Claus reaction in
functional ILs aqueous solutions, it can be found that the addition
of lactic acid increases the conversion of SO2 via the
Claus reaction, but the increase is limited. Moreover, the SO2 absorption capacity decreases with the addition of lactic
acid, but the decrease is not significant compared to the addition
of H2SO4.
Stoichiometry
of the Claus Reaction in Functional
Ionic Liquids Aqueous Solution
Through the above research,
it can be found that the stoichiometry of the Claus reaction is different
in the presence of water or the no-water case. We suppose that it
is mainly due to the different absorption mechanism in the two cases.Taking [MEA][Lac] as an example, the stoichiometry of SO2 absorption in absence of water is shown in Figure . It is speculated that the Claus reaction
mechanism in [MEA][Lac] in the absence of H2O is shown
in Figure .[33]
Figure 2
Stoichiometry of [MEA][Lac] absorbing SO2.
Figure 3
Stoichiometry of the Claus reaction in [MEA][Lac] after
absorbing
SO2.
Stoichiometry of [MEA][Lac] absorbing SO2.Stoichiometry of the Claus reaction in [MEA][Lac] after
absorbing
SO2.In the presence of water, the
stoichiometry of [MEA][Lac] absorbing
SO2 is shown in eqs and 5:[27,29]The stoichiometry of the Claus
reaction in [MEA][Lac] aqueous solution is shown in eq :It can be seen from the above
analysis whether the species of SO2 after absorption are
different in the presence of water or not, which results in a different
mechanism of the Claus reaction. In an aqueous solution, the absorbed
SO2 exists in species of H2SO3, HSO3–, and SO32–. There is an equilibrium of ionization and hydrolysis between the
three substances, which is mainly affected by pH of the solution.
With the consumption of H+ during the Claus reaction, the
alkalinity of the solution gradually increases, and the absorbed SO2 mainly exists in SO32–, which
cannot react with H2S. However, in the absence of water,
SO2 is directly absorbed by ILs to form IL-SO2. During the Claus reaction, the chemical bond between SO2 and IL is broken, and the SO2 reacts with H2S. In the process, the existing form of SO2 does not change
after being absorbed, and its ability of reacting with H2S does not decrease. Instead, the pure IL environment provides a
unique ionic environment, which has certain catalysis effect on the
Claus reaction. Therefore, the presence of water influences not only
the reaction rate but also the conversion of SO2 via the
Claus reaction of H2S with SO2 absorbed in functional
ILs. However, it has been found that the addition of lactic acid increases
the conversion of SO2 via the Claus reaction. This work
provides the information on the Claus reaction for the absorbed SO2 not only by functional ILs but also by functional deep eutectic
solvents in the presence of water.
Conclusions
In this work, we mixed water with three functional ILs to yield
aqueous absorbents of [MEA][Lac] + H2O, [TMG][Lac] + H2O, and [N2222][Lac] + H2O, and studied
the effect of water on the Claus reaction in three absorbents due
to the presence of water in flue gas and then in absorbents. The result
shows that the addition of water into ILs can reduce the conversion
of absorbed SO2, and the conversion increases as the acidity
of absorbents increases. To explain this phenomenon, the Claus reaction
was performed in H2SO3, NaHSO3, and
Na2SO3 aqueous solutions. It turns out that
the conversion of SO2 via the Claus reaction is related
to the species of S (IV), the conversion rate, H2SO3 > HSO3– > SO32–, and their proportions dependent on the pH of
solutions.
On the basis of the absorption mechanism of SO2 in functional
ILs aqueous solution, H2S reacts with HSO3– and SO32– with weaker
oxidability, resulting in the lower conversion rate.
Experimental Section
Materials
SO2 (99.95%),
H2S (99.95%), and N2 (99.99%) were obtained
from Beijing Beiwen Gases Co., Ltd. (Beijing, China). Simulated flue
gas with SO2 (2%) was prepared by mixing SO2 and N2 in a 40 dm3 high-pressure cylinder.
Analytical reagent 1,1,3,3-tetramethylguanidine (99%), tetraethylammonium
hydroxide (25% in water), ethylene glycol (EG), and lactic acid (85%–90%
in water) were obtained from Aladdin Chemical Co., Ltd. (Shanghai,
China). Monoethanolamine (99%) was purchased from Alfa Aesar
(China) Chemicals Co. Ltd., (Beijing, China). NaOH (97%), H2SO3, NaHSO3, and Na2SO3 were purchased from Beijing Chemical Works (Beijing, China). All
reactants and solvents were A.R. grade.[MEA][Lac], [TMG][Lac],
and [N2222][Lac] with different mass fractions of water
or EG were synthesized and characterized following the literature.[34] The water contents in the absorbents were determined
by Karl Fischer titration (Leici ZDY-502, China).
Absorption of Low-Concentration SO2 in Absorbents
The schematic diagram of the apparatus is
shown in Figure .
The simulated flue gas with 2% SO2 with a flow of 100 cm3/min was bubbled through water and absorbents successively
to offset the reduction of water contents of absorbents. The concentrations
of SO2 in absorbents were analyzed using an iodine titration
method (HJ/T 56–2000, a standard method of the State Environmental
Protection Administration of China). After a period of absorption,
the concentration of SO2 no longer changed, meaning that
the absorbents were saturated.
Figure 4
Schematic diagram of the apparatus for
ILs to absorb SO2 from a flue gas stream. 1, Simulated
flue gas cylinder; 2, pressure
reducing value; 3, rotameter; 4, glass tube with H2O; 5,
glass tube with absorbents; 6, tail gas absorption device; 7, water
bath.
Schematic diagram of the apparatus for
ILs to absorb SO2 from a flue gas stream. 1, Simulated
flue gas cylinder; 2, pressure
reducing value; 3, rotameter; 4, glass tube with H2O; 5,
glass tube with absorbents; 6, tail gas absorption device; 7, water
bath.
Regeneration
of Absorbents via the Claus Reaction
The regeneration method
was the same as that reported in the literature.[25] Briefly, the regeneration reaction was carried
out in a stainless-steel chamber (25.641 dm3) equipped
with a temperature sensor (±0.1 °C), a pressure sensor (±0.01
MPa), and a magnetic stirrer. A sample of SO2-absorbed
functional IL with or without water was loaded in the chamber, and
the air in the chamber was removed using N2. H2S was charged into the chamber to a desired pressure, and then the
Claus reaction was started. The pressure in the chamber was recorded
at certain time intervals until the pressure remained constant, indicating
that the reaction reached its equilibrium.The conversion of
SO2 in the Claus reaction was calculated via the recovery
ratio of sulfur (RS). After the Claus
reaction, pure sulfur was obtained by centrifugation, washing, and
drying. Because of the physical absorption of H2S, the
residual H2S in the regenerated absorbents was easily removed
by a decompression method, and then it could be used for SO2 absorption.
Authors: Amanda C Cole; Jessica L Jensen; Ioanna Ntai; Kim Loan T Tran; Kristin J Weaver; David C Forbes; James H Davis Journal: J Am Chem Soc Date: 2002-05-29 Impact factor: 15.419