Annalisa Ossola1, Eros Mossini1, Elena Macerata1, Walter Panzeri2, Andrea Mele2,3, Mario Mariani1. 1. Department of Energy, Politecnico di Milano, Piazza L. da Vinci 32, I-20133 Milano, Italy. 2. C.N.R. - Consiglio Nazionale delle Ricerche, Istituto di Scienze e Tecnologie Chimiche "G. Natta" (SCITEC), Sezione "U.O.S. Milano Politecnico", 20133 Milano, Italy. 3. Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, Piazza L. da Vinci, 32, 20133 Milano, Italy.
Abstract
Within a spent nuclear fuel recycling strategy, in the past few years, the pyridine-bis-triazole unit was found to be rather effective and selective in minor actinide (MA) separation from synthetic high active raffinate (HAR). In this research work, the main features of the recently studied PTEH ligand were investigated in order to evaluate its potentialities in SANEX-like processes. Its applicability in advanced separation processes was demonstrated, even at process temperatures. It manifested satisfactory extraction properties for a successful selective An separation from Ln, easy cation release, and adequate extraction kinetics as well as outstanding hydrolytical and radiolytical stability. All the results collected in this work allowed the scientists on the committee of the H2020 GENIORS project to promote PTEH as a concrete alternative to the reference CyMe4-BTBP ligand.
Within a spent nuclear fuel recycling strategy, in the past few years, the pyridine-bis-triazole unit was found to be rather effective and selective in minor actinide (MA) separation from synthetic high active raffinate (HAR). In this research work, the main features of the recently studied PTEH ligand were investigated in order to evaluate its potentialities in SANEX-like processes. Its applicability in advanced separation processes was demonstrated, even at process temperatures. It manifested satisfactory extraction properties for a successful selective An separation from Ln, easy cation release, and adequate extraction kinetics as well as outstanding hydrolytical and radiolytical stability. All the results collected in this work allowed the scientists on the committee of the H2020 GENIORS project to promote PTEH as a concrete alternative to the reference CyMe4-BTBP ligand.
Recent
United Nations projections disclose the population to increase
to 9.5 billion by 2050 before stabilizing at around 10–12 billion
by 2100. Consequently, the global energy demand is expected to considerably
increase too.[1] Nowadays, fossil fuels still
represent the main source of energy, although they are considered
the major responsibility of greenhouse gas (GHG) release. From this
viewpoint, nuclear power has a significant potential to contribute
to GHG emissions reduction, since emissions comparable with those
of renewable energy sources are generated during the entire nuclear
power plant life, from construction to decommissioning, including
the nuclear fuel cycle.[2] However, the development
of nuclear energy is strongly limited by production, long-term management,
and disposal of high level waste (HLW).[3] IAEA estimates that about 370000 tHM of spent nuclear
fuel (SNF) have been discharged since the start of nuclear power based
electricity production in 1954 to the end of 2013. In addition, more
than 10,000 tons are discharged every year.[4,5] Nowadays,
only uranium and plutonium are reprocessed on an industrial scale
by the conventional PUREX (Plutonium and URanium EXtraction) process
to produce mixed oxide (MOX) fuel. Up to 2013, about one-third of
discharged SNF (12,4000 tHM) was already reprocessed for
the production of MOX fuel to be used in light water reactors. However,
this process itself produces a high active raffinate, which is currently
vitrified and requires storage in deep geological repositories for
3,000–10,000 years, since it still contains long-term radiotoxic
minor actinides, such as Np, Am, and Cm, and fission products (FP).[6] In this perspective, since the 1980s, the separation
of transplutonium actinides from lanthanides (Ln) and the remaining
FP, in view of their subsequent use as new nuclear fuel in fast reactors,
has gained significant attention.[7−9] This approach would increase
the public acceptance of nuclear energy by improving the natural resources
exploitation, obtaining shorter-lived or even stable nuclides, reducing
the required storage time but also the radiotoxic inventory and capacity
needs of repositories, and enhancing the long-term resistance toward
proliferation.[10] During the last decades,
considerable scientific and technical efforts have been dedicated
to the development of processes for the recovery of MA from high level
waste, and many extractants have been studied to accomplish this challenging
task. Particular attention has been placed on the employment of hydrophilic
or lipophilic ligands constituted only by C, H, O, and N atoms, in
order to be completely incinerable without generating secondary solid
waste at the end of their life.[11] In Europe,
since the early 2000s, the regular-Selective ActiNide
EXtraction (r-SANEX) process has been developed to
selectively separate trivalent MA from the Ln contained in the downstream
of the previous DIAMEX (DIAMide EXtraction) process. Subsequently,
its variant, the 1-cycle-SANEX (1-c-SANEX) process, has been developed as a more compact and simplified
separation process aiming at directly recovering trivalent MA from
the HAR of a PUREX-like process.[12] Many
heteroaromatic nitrogen donor lipophilic ligands, such as bis-triazine-pyridine/bis-pyridine/phenantroline
(BTP, BTBP, and BTPhen), have been investigated for the selective
MA extraction in r-SANEX and 1-c-SANEX processes. They are characterized by a remarkable MA/Ln selectivity;
however, the majority suffers from kinetic or stability problems in
the harsh solvent extraction conditions.[13,14] In particular, the reference CyMe4-BTBP (6′-bis(5,5,8,8-tetramethyl-5,6,7,8-tetrahydro-benzo[1,2,4]triazin-3-yl)-[2,2′]
bipyridine) represents the most studied of BTBP ligands and was the
first r-SANEX extracting agent to combine high, but
reversible, affinity toward trivalent MA together with satisfactory
hydrolytical and radiolytical stability.[15] However, it is also characterized by limited solubility, slow kinetics,
and scarce loading capability which have been partially solved by
using specific diluents and/or phase transfer catalysts, hence complicating
the extracting solvent.[16−19] In more recent years, the pyridine-bis-triazole (PyTri)
chelating unit was found to be promising for the selective An separation
from simulated nuclear waste.[20−23] Among the lipophilic PyTri ligands studied, preliminary
promising efficiency and selectivity data were collected for the 2,6-bis(1-(2-ethylhexyl)-1H-1,2,3-triazol-4-yl)pyridine
(PyTri-ethyl-hexyl – PTEH) ligand, reported in Figure .[24] Moreover, even if, due to the different experimental conditions
employed, the properties of PTEH and CyMe4-BTBP ligands cannot be compared quantitatively, these preliminary
data showed that PTEH could be a promising alternative
to the reference CyMe4-BTBP extractant. The aim of this
work is to further investigate PTEH performances, thus
also demonstrating the potential advantages that PTEH could have over CyMe4-BTBP. As an example, a faster extraction
kinetics is an undeniable requirement for the industrial implementation
of the process and would simplify the extracting system since the
addition of catalysts into the organic phase would not be necessary.
Therefore, the main features of the newly synthesized PTEH ligand were investigated in order to evaluate its potentialities
in SANEX-like processes and, eventually, promote it as a valid alternative
to the current reference molecule. In particular, the extraction performances
of the PTEH solvent were ascertained as a function of
different process parameters, such as ligand concentration, temperature,
and feed composition. Moreover, some insights on metal–ligand
complex stoichiometry and system stability toward aging, hydrolysis,
and radiolysis were gathered.
Figure 1
Molecular structure of PyTri-ethyl-hexyl (PTEH).
Molecular structure of PyTri-ethyl-hexyl (PTEH).
Experimental Section
General Methods and Chemicals
2,6-Bis(1-(2-ethylhexyl)-1H-1,2,3-triazol-4-yl)pyridine
(PTEH) was supplied by the University of Parma (Department
of Chemistry, Life Sciences and Environmental Sustainability) and
synthesized according to the procedure elsewhere reported.[24]All commercially available reagents and
chemicals used in this study were analytical reagent grade and used
without further purification. Kerosene (reagent grade, low odor, aliphatic
fraction >95%) and 1-octanol (purity ≥99%), both supplied
by
SIGMA-Aldrich, were used as diluents. The organic solutions were prepared
by dissolving weighed amounts of PTEH extractant in mixtures
of kerosene + 10 vol % 1-octanol.Nitric acid solutions were
prepared by diluting concentrated nitric
acid (from Fluka, ≥65% w/w) with ultrapure water (Millipore,
Billerica, USA; 18.2 MΩ·cm). The stock solution of 241Am was supplied by Eurostandard CZ (Czech Republic), and
the radiotracers 152Eu and 244Cm were supplied
by CERCA-LEA (France). Hexahydrated nitrates of La, Ce, Pr, Nd, Sm,
Eu, and Gd (purity from 99 to 99.99%) and YCl3·6H2O (99.8%), purchased from Sigma-Aldrich, were used to prepare
simplified synthetic feed stock solutions in HNO3 at different
concentrations.
Extraction Experiments
Preceding
the liquid–liquid extraction tests, the organic phases were
pre-equilibrated with an equal volume of nitric acid, of suitable
concentration, to guarantee that the aqueous phase acidity would not
change during the tests. Afterward, the tests were performed according
to a standard protocol. The pre-equilibrated organic phases were contacted
in closed single-use Eppendorf microtubes with an equal volume of
aqueous phases containing the cations to be extracted and energetically
shaken by a mixer for 1 h at controlled temperature (22 ± 1 °C),
if not otherwise specified. After centrifugation for achieving complete
phases separation, an aliquot of 200 μL of each phase was collected.
The activity of the radiotracers in each phase was quantified by γ-spectrometry
(2′′ × 2′′ NaI(Tl), Silena SNIP N
MCA) exploiting the γ-lines of 241Am and 152Eu at 59.5 and 121.8 keV, respectively. Instead, following proper
sample preparation by diluent evaporation to dryness on a steel planchet,
the activity concentrations of 241Am and 244Cm were measured by means of α-spectrometry (ORTEC OCTÊTE
PLUS alpha spectrometer) taking advantage of their main α-lines
at 5.485 MeV and 5.804 MeV, respectively. In order to minimize mass
balance errors, the results obtained for 244Cm were normalized
on the activity concentrations of 241Am obtained from γ
and α spectrometries. Instead, the concentration of stable elements
(Y and Ln) was assessed by inductively coupled plasma mass spectrometry
(ThermoFisher X-SeriesII ICP-MS). While the aqueous phases were directly
measured after appropriate dilution with ultrapure 1 vol % HNO3, the organic phases were mixed with the nonionic surfactant
TRITON-X-100 before dilution to a suitable cation concentration. The
ICP-MS calibration solutions were purchased from INORGANIC VENTURES
(Christiansburg, Virginia).Extraction tests were considered
reliable only if no third phase formation was observed and the activity
balance was 100 ± 5%.Distribution ratios, DM, were computed
as the ratio between the concentration of the cations (M) in the organic
phase and that in the aqueous phase. The error linked to distribution
ratios between 0.01 and 100 is about ±5%, while it rises up to
±20% for values outside this range. The selectivity is described
by the separation factor (SFAn/Ln) which is the ratio
of DAn over DLn, namely DAn/DLn.According to the procedure above-described, different types
of
experiments were conducted:
Ligand Concentration
Dependence
In order to evaluate the impact of PTEH concentration
on system performances, different extraction tests were performed
with variable ligand concentrations (from 0.12 to 0.20 M) dissolved
into the kerosene + 10 vol % 1-octanol mixture, optimized in a previous
work.[24] The pre-equilibrated organic phases
were contacted with 3 M nitric acid solutions spiked with trivalent 241Am, 244Cm, and 152Eu.
Complex Stoichiometry
In order
to deepen the study of PTEH selectivity and obtain some
preliminary information regarding the stoichiometry of metal/ligand
complexes formed by PTEH, a slope analysis has been performed
on the results of ligand concentration dependence experiments (see
point 1).
Extraction Kinetics
Since the extraction
kinetics of a system is a very important parameter to be evaluated
in view of an application to the apparatus employed in multistage
processes, such as centrifugal contactors and mixer-settlers, liquid–liquid
extraction tests were performed varying the mixing time from 5 to
60 min. In particular, the mixing has been performed in microtubes
by a Thermo Fisher mixer at 1100 rpm at controlled temperature. The
pre-equilibrated organic phases (0.2 M PTEH in kerosene
+ 10 vol % 1-octanol) were contacted with 3 M nitric acid solutions
spiked with trivalent 241Am and 152Eu.
Selectivity toward Ln
In order
to further assess the PTEH selectivity for MA toward
the Ln series, solvent extraction tests were performed employing a
more complex aqueous feed (see Table ). The quantity and relative proportion of Y and Ln
in such an aqueous feed were previously defined so as to better mimic
a simplified PUREX raffinate. The pre-equilibrated organic phases
(0.2 M PTEH in kerosene + 10 vol % 1-octanol) were contacted
with 1 to 3 M nitric acid solutions (see Table for composition).
Table 1
Composition
of the Simplified Synthetic
Feed Solution Used in the Liquid–Liquid Extraction Tests
element
concn [mg/L]
element
concn [mg/L]
241Am
traces
Pr
269
152Eu
traces
Nd
904
Y
85
Sm
189
La
301
Eu
36
Ce
706
Gd
63
Temperature Dependence
With a view
to obtain some information regarding the system performances at process
temperatures (30 ≤ T ≤ 40 °C),
some solvent extraction tests were carried out by varying the temperature
in the 20 ≤ T ≤ 50 °C range. The
pre-equilibrated organic phases (0.2 M PTEH in kerosene
+ 10 vol % 1-octanol) were contacted with 3 M nitric acid solutions
spiked with trivalent 241Am, 244Cm, and 152Eu.
Resistance toward Hydrolysis
and Radiolysis
Preliminary information about the ligand radiochemical
stability
was obtained by performing liquid–liquid extraction tests and
HPLC (high performance liquid chromatography) coupled with ESI-MS
(electrospray ionization - mass spectroscopy) analyses on pre-equilibrated PTEH solutions irradiated up to 300 kGy by means of a 60Co source (2.5 kGy/h dose rate). In some cases, the organic
phases were irradiated in contact with an equal amount of 3 M HNO3 in order to evaluate its impact on the system degradation.
In order to estimate the radiolysis effect, some reference solutions
were not irradiated but just aged in the dark at room temperature
(i.e., 22 ± 1 °C) for the same length of time, whether in
contact or not with 3 M HNO3. All samples were stored in
the dark at 4 ± 1 °C until the irradiation at the highest
absorbed dose was completed. Consequently, the same thermal treatment
was guaranteed to all samples. Preceeding aging/irradiation, all organic
solutions were pre-equilibrated with an equal volume of 3 M HNO3. The liquid–liquid extraction experiments were performed
by contacting each aged and irradiated organic phase with fresh solutions
of 3 M HNO3 spiked with trivalent 241Am, 244Cm, and 152Eu. The results were compared with
those obtained with a fresh PTEH solution. The chemical
composition of the irradiated samples was characterized by HPLC coupled
with ESI-MS techniques. HPLC-MS analyses were performed with 1100
Series (Agilent) and Bruker Esquire 3000 PLUS instruments. The former
was equipped with a Purospher STAR RP-18 end-capped column (3 μm).
The latter exploits an ESI Ion Trap LC/MSn System, equipped with an
ESI source and a quadrupole ion trap detector (QIT). ESI-MS acquisitions
were executed on HPLC outflow, set to 0.5 mL/min (flow rate limit).
HPLC-MS measurements were performed at 30 °C using an isocratic
mobile phase [(A: CH3CN/TFA 0.1% v/v), (B: H2O)]. The assignment of some of the species detected was confirmed
also by direct ESI-MS analysis. The m/z species of interest were isolated, fragmented, and detected (MS2) to ease the byproduct identification.
Cation Release Capability
With
the aim to verify the release of complexed cations, necessary both
in view of organic solvent recycling and of further purification steps
prior to fuel elements manufacturing, back-extraction tests were performed
on loaded fresh, aged, and irradiated organic phases (0.2 M PTEH in kerosene + 10 vol % 1-octanol). As a matter of fact,
the removal of complexed metal ions and the organic solvent recycling
would improve economics and sustainability of the future reprocessing
plant. Even if the ligand is selective for MA, since small amounts
of Ln could be extracted anyway, it is important to verify also their
release. In fact, if kept in the organic phase, they could cause problems
in the long term operation of the plant. In order to keep the solvent
formulations as simple as possible, namely without the introduction
of new reagents, diluted nitric acid solutions were employed for cation
back-extraction as it was previously proposed for other lipophilic
extractants, except for the BTBPs that required the addition of glycolic
acid to the aqueous stripping solution.[15] Thus, the back-extraction tests were performed with fresh 0.1 M
HNO3 solutions.
Results
and Discussion
The promising properties of PTEH in kerosene/1-octanol
mixtures have already been outlined and are reported in a previous
work.[24] In particular, among the lipophilic
PyTri compounds formerly investigated, only PTEH resulted
in being well soluble in all the tested diluents, especially in kerosene/1-octanol
mixtures usually employed for other extractants. Its optimal working
diluent mixture was found to be kerosene + 10 vol % 1-octanol. In
such conditions, D-values of 241Am and 152Eu increase by increasing nitric acid concentration in the
aqueous phase. In particular, DEu was
always well below 1, while DAm was under
the unity at 1 M nitric acid concentration of the aqueous phase and
increases up to 5.5 at 3 M nitric acid concentration of the aqueous
phase. Thus, an effective separation of 241Am from 152Eu is achieved for HNO3 concentrations of the
aqueous phase higher than 2 M. The SF of Am(III)
over Eu(III) were found to be close to and, in some cases, even higher
than 80, resembling the values found for the promising hydrophilic
PyTri compounds,[20] and for these reasons
its performances have been more widely investigated in this work.
Ligand Concentration Dependence
The
distribution ratios of trivalent 241Am, 244Cm,
and 152Eu as a function of the PTEH concentration
are reported in Figure . From the data, it was possible to compute the decontamination factors,
reported in Table , as the ratio between the activity concentration of radionuclides
in the feed (i.e., aqueous phase to be decontaminated) and in the
raffinate (i.e., aqueous phase decontaminated by liquid–liquid
extraction). As observable, all the D-values linearly increase with
increasing ligand concentration. Contrarily, Eu(III) decontamination
factors are not significantly influenced by PTEH concentration
and remain close to unity, further confirming the scarce affinity
of the ligand toward Ln. Although the process requirements are successfully
fulfilled in all the conditions, the employment of the highest ligand
concentration, leading to the highest 241Am and 244Cm D-values, guarantees a broader safety margin toward possible system
composition alteration. Interestingly, although unsatisfactory, separation
factors between Cm and Am of 1.46 ± 0.21, 1.54 ± 0.22, and
1.43 ± 0.20 were obtained for ligand concentrations of 0.12,
0.16, and 0.20 M, respectively.
Figure 2
D-values and SFs of 241Am, 244Cm, and 152Eu as a function
of PTEH concentration.
Organic phase: PTEH in kerosene + 10 vol % 1-octanol
mixture. Aqueous phase: 3 M HNO3 solutions spiked with
trivalent 241Am, 244Cm, and 152Eu
(ca. 10 kBq/mL each).
Table 2
Decontamination
Factor at Increasing
PTEH Ligand Concentration in the Organic Phase
decontamination
factor
[PTEH]
0.12 M
0.16 M
0.2 M
241Am
3.0 ± 0.3
4.6 ± 0.5
6.8 ± 0.7
244Cm
3.9 ± 0.4
6.5 ± 0.7
9.3 ± 0.9
152Eu
1.0 ± 0.1
1.0 ± 0.1
1.1 ± 0.1
D-values and SFs of 241Am, 244Cm, and 152Eu as a function
of PTEH concentration.
Organic phase: PTEH in kerosene + 10 vol % 1-octanol
mixture. Aqueous phase: 3 M HNO3 solutions spiked with
trivalent 241Am, 244Cm, and 152Eu
(ca. 10 kBq/mL each).
Complex
Stoichiometry
The same data
reported in Figure can be processed and plotted as the logarithm of the D-values as
a function of the logarithm of ligand concentration, as reported in Figure . This data processing
approach, the so-called slope analysis, is useful to obtain preliminary
information on metal/ligand complex stoichiometry.
Figure 3
Logarithm of D-values
of 241Am, 244Cm, and 152Eu as a function
of the logarithm of PTEH concentration,
at 22 ± 1 °C. Organic phase: PTEH in kerosene
+ 10 vol % 1-octanol. Aqueous phase: 3 M HNO3 solutions
spiked with trivalent 241Am, 244Cm, and 152Eu (ca. 10 kBq/mL each).
Logarithm of D-values
of 241Am, 244Cm, and 152Eu as a function
of the logarithm of PTEH concentration,
at 22 ± 1 °C. Organic phase: PTEH in kerosene
+ 10 vol % 1-octanol. Aqueous phase: 3 M HNO3 solutions
spiked with trivalent 241Am, 244Cm, and 152Eu (ca. 10 kBq/mL each).Slopes of 2.06 ± 0.05, 2.03 ± 0.10, and 2.30 ± 0.05
were derived from the linear regression of Am(III), Cm(III), and Eu(III)
data, respectively. This entails the prevailing presence of 1:2 metal/ligand
complex stoichiometry. Analogous complex stoichiometry can be found
in the literature for the CyMe4-BTBP ligand in 1-octanol,
that is the reference SANEX solvent.[15] The
equilibrium reaction reported in eq shows the simplified probable PTEH complexation
with An and Ln cations.Hypothesized
complexation mechanism of PTEH with trivalent cations
Extraction Kinetics
The aim of this
experiment is evaluating the required mixing time for achieving the
equilibrium. As reported in Figure , the equilibrium resulted in being almost reached
within 10 min of mixing. Thanks to these results, all other data reported
in this manuscript and obtained after 60 min of mixing are reliable,
since they describe the system at equilibrium. The relatively rapid
extraction kinetics for PTEH bodes well for its application
under countercurrent solvent extraction conditions using mixer-settlers
or pulsed columns, a potential benefit compared to the reference CyMe4-BTBP ligand which requires the employment of phase-transfer
catalysts to improve its very slow extraction kinetics.[16] The faster extraction kinetics shown by PTEH could ease the development of the process flow-sheet,
as the flow-rates could be increased and, consequently, the number
of extraction stages reduced with respect to CyMe4-BTBP,
without hampering the system performance.
Figure 4
D-values and SFs of 241Am and 152Eu as a function
of mixing time. Organic phase: 0.2 M PTEH in kerosene
+ 10 vol % 1-octanol. Aqueous phase: 3 M
HNO3 solutions spiked with trivalent 241Am and 152Eu (ca. 10 kBq/mL each).
D-values and SFs of 241Am and 152Eu as a function
of mixing time. Organic phase: 0.2 M PTEH in kerosene
+ 10 vol % 1-octanol. Aqueous phase: 3 M
HNO3 solutions spiked with trivalent 241Am and 152Eu (ca. 10 kBq/mL each).
Selectivity toward Ln
Figure shows the D-values of trivalent
Am and Ln as a function of nitric acid concentration of the aqueous
phase. The aim of this experiment is assessing the capability of PTEH of selectively extracting MA in the presence of a more
complicated and representative aqueous feed. In all cases, 152Eu data obtained by gamma spectrometry were found to be consistent
with those of stable europium obtained from mass spectrometry, even
if 152Eu is in tracer concentration while the second is
at approximately 36 mg/L. Coherently with the results obtained with
radiotraced solutions,[24] the D-values of all these cations increase at increasing nitric acid concentration
of the aqueous phase. In particular, at 1 M nitric acid concentration
of the aqueous feed, the 241Am D-value
is below the unity and, thus, unsuitable for extraction of Am from
the aqueous feed. Contrarily, an effective separation of 241Am from Y and Ln was obtained for nitric acid concentrations higher
than 2 M. Promising SF between 241Am and
trivalent Ln were obtained and are reported in Table S1. As an example, at 3 M nitric acid concentration
of the aqueous feed, the SF between Am and the less
and the most extracted Ln, namely Nd and Gd, are about 340 and 66,
respectively.
Figure 5
D-values of trivalent 241Am, 152Eu, Y, and
lighter Ln (La–Gd) as a function of the nitric acid concentration
of the aqueous phase. Organic phase: 0.2 M PTEH in kerosene
+ 10 vol % 1-octanol mixture. Aqueous phase: HNO3 solutions
loaded with Y and lighter Ln (La–Gd) for a total concentration
of about 0.02 M, besides trivalent 241Am and 152Eu as radiotracers (ca. 10 kBq/mL each)
D-values of trivalent 241Am, 152Eu, Y, and
lighter Ln (La–Gd) as a function of the nitric acid concentration
of the aqueous phase. Organic phase: 0.2 M PTEH in kerosene
+ 10 vol % 1-octanol mixture. Aqueous phase: HNO3 solutions
loaded with Y and lighter Ln (La–Gd) for a total concentration
of about 0.02 M, besides trivalent 241Am and 152Eu as radiotracers (ca. 10 kBq/mL each)The aqueous feed decontamination factors obtained with 0.2 M PTEH in kerosene + 10 vol % 1-octanol solutions, as a function
of the nitric acid concentration of the aqueous phase, are displayed
in Table . They were
calculated as the ratio between the activity concentration of radionuclides,
or concentration of the stable elements, in the aqueous feed and in
the raffinate. As noticeable, by increasing the nitric acid concentration
of the aqueous phase from 1 to 3 M, higher Am(III) decontamination
factors were achieved, in agreement with results of Table . Conversely, in the same range,
no significant changes in the 152Eu(III) decontamination
were highlighted. In addition, the decontamination factors related
to the stable Ln remain constant around approximately 1 in all the
extraction conditions, implying that Ln are scarsely extracted into
the organic phase.
Table 3
Decontamination Factors of Aqueous
Feed as a Function of Nitric Acid Concentration of the Aqueous Phase
decontamination
factor
HNO3,eq
1 M
2 M
3 M
241Am
1.2 ± 0.1
3.8 ± 0.4
7.0 ± 0.7
152Eu
1.0 ± 0.1
1.0 ± 0.1
1.1 ± 0.1
Ln
1.0 ± 0.1
1.0 ± 0.1
1.0 ± 0.1
Temperature
Dependence
Basic information
about the temperature influence on system performances can be derived
from the slopes of the D vs temperature plot (see Figure ). This experiment
provides meaningful results, since temperature fluctuations may occur
in the future industrial facility and affect the extraction process.
Figure 6
D-values
of 241Am and 152Eu and SFAm/Eu as
a function of T. Organic phase: 0.2 M PTEH in kerosene + 10 vol % 1-octanol. Aqueous phase: 3 M
HNO3 solutions spiked with trivalent 241Am and 152Eu (ca. 10 kBq/mL each).
D-values
of 241Am and 152Eu and SFAm/Eu as
a function of T. Organic phase: 0.2 M PTEH in kerosene + 10 vol % 1-octanol. Aqueous phase: 3 M
HNO3 solutions spiked with trivalent 241Am and 152Eu (ca. 10 kBq/mL each).In particular, the slopes depict the sensitivity of each extracted
element toward temperature variation: the bigger the slope is, the
higher the sensitivity is. Therefore, as noticeable from Figure , a slightly higher
variation of 241Am distribution ratios with respect to 152Eu could be inferred. In fact, 241Am extraction
slightly decreases with increasing the temperature, thus suggesting
an exothermic nature of its extraction equilibria. Instead, 152Eu extraction appeared not to be affected by temperature. A confirmation
of these different trends is given by the separation efficiency (241Am/152Eu) which decreases from 79 to 54 as the
temperature increases from 20 to 50 °C, respectively. However,
the system performance remains absolutely satisfactory in the whole
temperature range considered.Further studies are in progress
in order to deepen and better understand
the PTEH extraction mechanism. Additional techniques
could also be exploited, such as TRLFS, UV–vis, or calorimetry.
Resistance toward Hydrolysis and Radiolysis
The results of solvent extraction experiments executed with irradiated
and/or aged PTEH solutions are reported in Figure S1. Regarding aging, after pre-equilibrium, PTEH solutions were left to age in the dark at room temperature
(22 ± 1 °C) for 71 days (see Figure S1, test ii). Instead, about hydrolysis, other
solutions were aged for 169 days in contact with an equal volume of
3 M nitric acid (see Figure S1, test iii), always in the dark at room temperature (22 ±
1 °C). Concurrently, other pre-equilibrated solutions were subjected
to gamma irradiation at 100, 200, and 300 kGy, not in contact (see Figure S1, tests iv, v, and vi, respectively) or in contact
with an equal volume of 3 M nitric acid (see Figure S1, tests vii and viii).
In order to ascertain the effect of radiolysis alone, the first set
of tests (namely tests iv, v, and vi), which underwent aging and radiolysis, must be compared
with test ii, which instead underwent only aging
for the same period of time. Instead, the second set of tests (namely
tests vii and viii), which underwent
both hydrolysis and radiolysis, must be compared with test iii, which underwent only hydrolysis for the same period
of time. As reference, liquid–liquid extraction tests were
carried out with pre-equilibrated fresh PTEH solutions
(see Figure S1, test i). As discernible, no significant variations of the extraction efficiency
were pointed out for solutions subjected to aging, hydrolysis, and
irradiation up to 300 kGy with respect to the results of the fresh
solution. In fact, alterations of both D-values of 241Am, 244Cm, and 152Eu and of the corresponding SFs are within the experimental uncertainty. A comparable
radiochemical stability has been highlighted also for the hydrophilic
PyTri compound, PyTri-diol.[25]With
the aim of further confirming the promising radiochemical stability
highlighted and attempting the identification of potential degradation
byproducts, HPLC-MS and direct ESI-MS analyses were performed on the
same fresh, aged, and irradiated PTEH solutions used
in the solvent extraction experiments.These analyses allowed
the identification of few new peaks in the
chromatograms of the aged and irradiated samples. With the purpose
of evaluating the ligand loss and following the evolution of the degradation
byproducts, a postprocessing of the HPLC-MS data was performed. The
ion currents of the new species were isolated and extracted as a function
of the analysis time. Afterward, for each degradated species, the
ratio between the ion current signal area and the total area of all
signals was evaluated (see Figure and Figure ). These peaks could be related to degradation byproducts
since they were absent in fresh solutions. As noticeable in Figure and in Figure , in both cases the
intensity signals of most of the species increased with aging and
irradiation.
Figure 7
HPLC-MS peak areas of PTEH main byproducts
(indicated
in g·mol–1) in different PTEH solutions:
(i) fresh, (ii) aged, (iii) irradiated at 100 kGy, and (iv) irradiated
at 200 kGy.
Figure 8
HPLC-MS peak areas of PTEH main
byproducts (indicated
in g·mol–1) in different PTEH solutions:
(i) fresh, (ii) aged in contact with 3 M HNO3, (iii) irradiated
at 100 kGy in contact with 3 M HNO3, and (iv) irradiated
at 200 kGy in contact with 3 M HNO3.
HPLC-MS peak areas of PTEH main byproducts
(indicated
in g·mol–1) in different PTEH solutions:
(i) fresh, (ii) aged, (iii) irradiated at 100 kGy, and (iv) irradiated
at 200 kGy.HPLC-MS peak areas of PTEH main
byproducts (indicated
in g·mol–1) in different PTEH solutions:
(i) fresh, (ii) aged in contact with 3 M HNO3, (iii) irradiated
at 100 kGy in contact with 3 M HNO3, and (iv) irradiated
at 200 kGy in contact with 3 M HNO3.The separation and subsequent fragmentation of each byproduct,
at its specific m/z, was obtained
by exploiting ESI-tandem mass (MS2) spectrometry, after
the ionization step. This allowed the proposal of some plausible hypotheses
about the structure of the observed species. Consistently with the
wide radiation chemistry literature[26−29] and with the hypothesized degradation
mechanism of the hydrophilic PyTri derivative,[21] the lateral branches were supposed to be the weakest part
of the ligand structure. Contrarily, the aromatic moieties were considered
as the most hydrolytically and radiolytically resistant part of the
ligand. Furthermore, ligand degradation is expected to be mainly attributable
to indirect radiolysis, i.e., to reactions with radiolytic species
of the diluent, rather than to direct interaction between radiations
and ligand. In particular, the radiolysis of the organic diluents
is expected to produce principally the solvated electron and its corresponding
alcohol radical cation as well as neutral carbon-centered α-hydroxy
radicals, according to equations reported in Table .[30]
Table 4
Main Alcohol Degradation Byproducts
equations
[RCH2OH] + γ →
[RCH2OH]*
[RCH2OH]*
→ esolv– + [RCH2OH]·+
[RCH2OH]·+ → RC·HOH
+ H+
All these radicals could interact with the extractant molecules.
In addition to 1-octanol radicals, it is known from the literature
that the presence of kerosene enhances solvent degradation, probably
due to the formation of additional reactive species from its degradation.[30] Besides radiolysis of organic solvent, even
nitric acid can undergo degradation. In particular, the principal
radiolytic species expected in the presence of oxygen and nitric acid
are NO3•, NO2•, and NO2-, in addition to water byproducts (H•, HO•, HO2•, and H2O2). Among all species generated by
radiolytic degradation of aqueous solutions, hydroxyl radicals (HO•) are the most reactive hydrogen abstracting agents
since hydrogen radicals (H•) are indeed quickly
converted to the less reactive HO2• radicals. As a consequence of hydrogen
atom abstraction from a C–H bond of the lateral chain, the
proposed degradation path involves the addition of radical species
coming from diluent radiolysis. Considering all these features, the
hypothesized structures of some of the byproducts are reported in Table .
Table 5
Hypothesized Structures of Identified
PTEH Byproducts
The ESI-MS2 acquisition allowed confirmation of some
of the above hypothesized species (see Figures S2–S4 and Tables S2–S4 in the Supporting Information). As reported, in all the hypothesized
byproduct structures, the complexing site is preserved. Therefore,
it is reasonable that the affinity toward MA of aged and irradiated
solutions is preserved with respect to fresh ones, in agreement with
extraction tests. Moreover, the lipophilicity seems to be not compromised.
Consequently, the organic solvent selectivity for MA should be unaltered,
since the complexes involving PTEH byproducts are not
expected to migrate to the aqueous phase.
Back-Extraction
Capability
Owing
to the exceptional hydrolytic and radiolytic stability manifested
by PTEH based solvent, back-extraction tests were performed
on fresh, aged, and irradiated loaded PTEH solutions.
As reported in Table , batch liquid–liquid extraction tests showed that a solution
of 0.1 M nitric acid is able to strip between 99.3% ÷ 99.9% and
89.7 ÷ 96.4% of the complexed Am and Eu cations, respectively,
in a single back-extraction step. Moreover, it seems that the presence
of degradation byproducts did not influence the cation release.
Table 6
Results of Back-Extraction
Tests Performed Contacting 0.1 M Nitric Acid Solution with the Following PTEH Loaded Solutions: (i) Fresh, (ii) Aged for 37 Days, (iii)
Aged for 37 Days in Contact with 3 M Nitric Acid, (iv) Irradiated
at 200 kGy, (v) Irradiated at 300 kGy, and (vi) Irradiated at 200
kGy in Contact with 3 M Nitric Acid
release %
test
Am
Eu
i
99.3%
89.7%
ii
99.9%
91.8%
iii
99.8%
95.0%
iv
99.7%
96.4%
v
99.6%
94.9%
vi
99.6%
90.8%
Those results are promising for fostering the recyclability
of PTEH solvent and the implementation of subsequent
MA purification
and conversion steps.
Conclusions
The
extraction properties of PTEH were extensively
studied in this work. Its promising MA selectivity was demonstrated
even in the presence of aqueous feed containing real waste concentrations
of Y and lighter Ln. Furthermore, its extraction kinetics was verified
to be sufficiently fast for implementation in industrial equipment
without the necessity to add phase-transfer catalysts, contrarily
to the reference CyMe4-BTBP ligand. The effect of temperature
on PTEH performances was successfully assessed, even
if a slightly decreasing trend of the Am(III)/Eu(III) SF was highlighted. Furthermore, the solvent stability toward aging,
hydrolysis, and gamma irradiation up to 300 kGy was positively demonstrated,
and the main degradation byproducts were hypothesized. Moreover, it
was proved that diluted nitric acid solutions are suitable for the
full release of the complexed cations from the loaded organic phases,
thus allowing feasible solvent recycling.In conclusion, thanks
to the PTEH promising extracting
properties, the scientists on the committee of the European GENIORS
project have promoted PTEH as a concrete alternative
to the reference CyMe4-BTBP ligand. Therefore, the PTEH ligand is worth being further studied in view of ascertaining
its applicability to the 1-c-SANEX process. As a
way of example, the well-known CyMe4-BTBP issues with some
fission and corrosion products (e.g., Mo, Zr, Pd, Ag) have been solved
by the addition of washing steps, masking agents, etc., but the management
of some other elements (e.g., Cd, Ni, Mn) still remains problematic.
In order to design a process as simple and effective as possible and
limit the amount of secondary waste produced, the influence of such
fission and corrosion products on PTEH extraction are
under investigation. Moreover, CyMe4-BTBP is characterized
by limited loading capability which hindered its application on high
metal loaded fuels, and so, the assessment of PTEH behavior
in the presence of high metal concentration could clarify if it is
able to overcome this issue. Additionaly, even PTEH capability
to extract TRansUranium (TRU) elements in all oxidation states will
be investigated with a view to be employed in GANEX (Grouped ActiNide
EXtraction)-like processes. Finally, additional activities aimed at
clarifying the complexation mechanism and the observed degradation
byproducts are ongoing.
Authors: Christoph Wagner; Eros Mossini; Elena Macerata; Mario Mariani; Arturo Arduini; Alessandro Casnati; Andreas Geist; Petra J Panak Journal: Inorg Chem Date: 2017-02-02 Impact factor: 5.165
Authors: Elena Macerata; Eros Mossini; Stefano Scaravaggi; Mario Mariani; Andrea Mele; Walter Panzeri; Nathalie Boubals; Laurence Berthon; Marie-Christine Charbonnel; Francesco Sansone; Arturo Arduini; Alessandro Casnati Journal: J Am Chem Soc Date: 2016-05-31 Impact factor: 15.419