Label free identification of the different status of anemia disease using optimized double-slot cascaded microring resonator.

Mahdi Bahadoran1, Abbas Kalate Seyfari2, Parisa Sanati3, Lee Suan Chua4,5.   

Abstract

An optical-based label-free biosensors including two indirectly coupled double-slot-waveguide-based microring resonator was designed and optimized for sensing purpose. Then, the optimized system was applied for the detection of hemoglobin concentration in anemia disease. The results were simulated based on the variational finite-difference time domain (varFDTD) method using the Lumerical software (Mode solutions) and the optimum geometrical parameters were determined to realize an optimum light transmission via the sensor. Nine different concentrations of hemoglobin in men and women were applied into the sensor and the status of anemia was identified based on the patients' gender and different status of anemia disease, including the normal, mild, moderate, severe and life-threatening status. A sensitivity as high as 1024 nm/RIU with the minimum deflection limit of 4.88 × 10-6 RIU were measured for this biosensor, which introduces a high precision and micro-scale lab-on-a-chip micro device for health monitoring of the anemia.
© 2022. The Author(s).

Entities:  

Mesh:

Year:  2022        PMID: 35365740      PMCID: PMC8975812          DOI: 10.1038/s41598-022-09504-2

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  18 in total

1.  Determination of the complex refractive index of highly concentrated hemoglobin solutions using transmittance and reflectance measurements.

Authors:  Moritz Friebel; Martina Meinke
Journal:  J Biomed Opt       Date:  2005 Nov-Dec       Impact factor: 3.170

2.  Detection of Salmonella bacterium in drinking water using microring resonator.

Authors:  Mahdi Bahadoran; Ahmad Fakhrurrazi Ahmad Noorden; Faeze Sadat Mohajer; Mohamad Helmi Abd Mubin; Kashif Chaudhary; Muhammad Arif Jalil; Jalil Ali; Preecha Yupapin
Journal:  Artif Cells Nanomed Biotechnol       Date:  2014-08-18       Impact factor: 5.678

3.  Measurement of refractive index of hemoglobin in the visible/NIR spectral range.

Authors:  Ekaterina N Lazareva; Valery V Tuchin
Journal:  J Biomed Opt       Date:  2018-03       Impact factor: 3.170

4.  Analytical microring stereo system using coupled mode theory and application.

Authors:  Amene Shafiee; Mahdi Bahadoran; Preecha Yupapin
Journal:  Appl Opt       Date:  2019-10-20       Impact factor: 1.980

5.  An evaluation of hemoglobin determination using sodium lauryl sulfate.

Authors:  A Karsan; I Maclaren; D Conn; L Wadsworth
Journal:  Am J Clin Pathol       Date:  1993-08       Impact factor: 2.493

6.  An azide-methemoglobin method for hemoglobin determination in blood.

Authors:  G Vanzetti
Journal:  J Lab Clin Med       Date:  1966-01

Review 7.  Chemotherapy-induced anemia in adults: incidence and treatment.

Authors:  J E Groopman; L M Itri
Journal:  J Natl Cancer Inst       Date:  1999-10-06       Impact factor: 13.506

8.  Spectroscopic phase microscopy for quantifying hemoglobin concentrations in intact red blood cells.

Authors:  YongKeun Park; Toyohiko Yamauchi; Wonshik Choi; Ramachandra Dasari; Michael S Feld
Journal:  Opt Lett       Date:  2009-12-01       Impact factor: 3.776

9.  Worldwide prevalence of anaemia, WHO Vitamin and Mineral Nutrition Information System, 1993-2005.

Authors:  Erin McLean; Mary Cogswell; Ines Egli; Daniel Wojdyla; Bruno de Benoist
Journal:  Public Health Nutr       Date:  2008-05-23       Impact factor: 4.022

10.  Modeling and analysis of a microresonating biosensor for detection of Salmonella bacteria in human blood.

Authors:  Mahdi Bahadoran; Ahmad Fakhrurrazi Ahmad Noorden; Kashif Chaudhary; Faeze Sadat Mohajer; Muhammad Safwan Aziz; Shahrin Hashim; Jalil Ali; Preecha Yupapin
Journal:  Sensors (Basel)       Date:  2014-07-18       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.