Validation of Home Visual Acuity Tests for Telehealth in the COVID-19 Era.

Kellyn N Bellsmith1, Michael J Gale1, Sen Yang1, Isabelle B Nguyen1, Christa J Prentiss1, Luan T Nguyen1, Sam Mershon1, Allison I Summers1, Merina Thomas1.   

Abstract

Importance: Visual acuity (VA) is one of the most important clinical data points in ophthalmology. However, few options for validated at-home VA assessments are currently available. Objective: To validate 3 at-home visual acuity tests in comparison with in-office visual acuity. Design, Setting, and Participants: Between July 2020 and April 2021, eligible participants with VA of 20/200 or better were recruited from 4 university-based ophthalmology clinics (comprehensive, cornea, glaucoma, and retina clinics). Participants were prospectively randomized to self-administer 2 of 3 at-home VA tests (printed chart, mobile phone app, and website) within 3 days before their standard-of-care clinic visit. Participants completed a survey assessing usability of the at-home tests. At the clinic visit, best-corrected Snellen distance acuity was measured as the reference standard. Main Outcomes and Measures: The at-home VA test results were compared with the in-office VA test results using paired and unpaired t tests, Pearson correlation coefficients, analysis of variance, χ2 tests, and Cohen κ agreement. The sensitivity, specificity, positive predictive value, and negative predictive value of each at-home test were calculated to detect significant VA changes (≥0.2 logMAR) from the in-office baseline.
Results: A total of 121 participants with a mean (SD) age of 63.8 (13.0) years completed the study. The mean in-office VA was 0.11 logMAR (Snellen equivalent 20/25) with similar numbers of participants from the 4 clinics. Mean difference (logMAR) between the at-home test and in-office acuity was -0.07 (95% CI, -0.10 to -0.04) for the printed chart, -0.12 (95% CI, -0.15 to -0.09) for the mobile phone app, and -0.13 (95% CI, -0.16 to -0.10) for the website test. The Pearson correlation coefficient for the printed chart was 0.72 (95% CI, 0.62-0.79), mobile phone app was 0.58 (95% CI, 0.46-0.69), and website test was 0.64 (95% CI, 0.53-0.73). Conclusions and Relevance: The 3 at-home VA test results (printed chart, mobile phone app, and website) appeared comparable within 1 line to in-office VA measurements. Older participants were more likely to have limited access to digital tools. Further development and validation of at-home VA testing modalities is needed with the expansion of teleophthalmology care.

Entities:  

Mesh:

Year:  2022        PMID: 35357405      PMCID: PMC8972145          DOI: 10.1001/jamaophthalmol.2022.0396

Source DB:  PubMed          Journal:  JAMA Ophthalmol        ISSN: 2168-6165            Impact factor:   8.253


  1 in total

1.  Comparing Home- and Clinic-Based Visual Acuity Testing.

Authors:  Michael D Crossland; Tessa M Dekker; Pete R Jones; Peter B M Thomas
Journal:  JAMA Ophthalmol       Date:  2022-10-01       Impact factor: 8.253