| Literature DB >> 35355970 |
Yeela Talmor-Barkan1,2, Ran Kornowski1, Noam Bar2, Jeremy Ben-Shoshan3, Hanna Vaknin-Assa1, Ashraf Hamdan1, Boris Kruchin1, Israel M Barbash4, Haim Danenberg5, Gidon Y Perlman5, Maayan Konigstein3, Ariel Finkelstein3, Arie Steinvil3, Ilan Merdler3, Amit Segev4, Alon Barsheshet1, Pablo Codner1.
Abstract
Background: Transcatheter heart valve (THV) selection for transcatheter aortic valve implantation (TAVI) is crucial to achieve procedural success. Borderline aortic annulus size (BAAS), which allows a choice between two consecutive valve sizes, is a common challenge during device selection. In the present study, we evaluated TAVI outcomes in patients with BAAS according to THV size selection.Entities:
Keywords: borderline aortic annulus; multi-detector computed tomography; paravalvular leak; transcatheter aortic valve implantation; valve hemodynamics
Year: 2022 PMID: 35355970 PMCID: PMC8959481 DOI: 10.3389/fcvm.2022.847259
Source DB: PubMed Journal: Front Cardiovasc Med ISSN: 2297-055X
Figure 1Valve selection in BAAS patients. BE, balloon-expandable; SE, self-expandable; THV, transcatheter heart valve; BAAS, borderline aortic annulus size; PVL, paravalvular leak.
Figure 2Flow chart for study cohort. BE, balloon-expandable; SE, self-expandable; THV, transcatheter heart valve, BAAS, borderline aortic annulus size.
Baseline clinical characteristics of patients with BAAS for SE-THV, implanted with SE or non-borderline BE-THV.
|
|
|
|
|
| |
|---|---|---|---|---|---|
| Female (%) | 52 (56) | 88 (58) | 50 (71) | 0.69 | 0.07 |
| DM (%) | 31 (33) | 55 (36) | 30 (42) | 0.68 | 0.55 |
| BMI kg/m2 | 27.6 ± 5.4 | 27 ± 4.6 | 27.9 ± 4.2 | 0.21 | 0.09 |
| STS score | 4.2 ± 2.3 | 4.3 ± 3.3 | 4.48 ± 2.86 | 0.29 | 0.28 |
| PR interval (ms) | 179.7 ± 40 | 171 ± 44 | 179 ± 38.7 | 0.13 | 0.09 |
| QRS interval (ms) | 120 ± 33 | 112 ± 35 | 104 ± 33 | 0.08 | 0.36 |
| NYHA functional class: | 0.03 | 0.38 | |||
| I | 0 (0) | 2 (1.4) | 1 (1.4) | ||
| II | 29 (33) | 31 (22) | 21 (31) | ||
| III | 51(58) | 78 (55) | 37 (54.4) | ||
| IV | 8 (9) | 30 (21) | 9 (13.2) |
Values are mean ± SD or [median, interquartile range (IQR)] or n (%). DM, diabetes mellitus; BMI, body mass index; STS score, the society of thoracic surgeons scores; NYHA, New York Heart Association; SE, self-expandable; BE, balloon-expandable; THV, transcatheter heart valve.
Smaller borderline-SE-THV vs. larger borderline-SE-THV.
Larger borderline-SE-THV vs. non-borderline-BE.
Baseline clinical characteristics of patients with BAAS for BE-THV, implanted with BE or non-borderline SE-THV.
|
|
|
|
|
| |
|---|---|---|---|---|---|
| Female (%) | 10 (45.4) | 24 (23.5) | 61 (63.5) | 0.06 | 1.40e-08 |
| DM (%) | 10 (45.4) | 43 (42.1) | 43 (44.8) | 1 | 0.24 |
| BMI kg/m2 | 28.6 ± 3.7 | 27.5 ± 4.4 | 28 ± 4.9 | 0.12 | 0.23 |
| STS score | 4 ± 4.5 | 3.4 ± 2.25 | 4.2 ± 2.4 | 0.36 | 0.003 |
| PR interval (ms) | 185 ± 60 | 181 ± 34 | 174 ± 34.18 | 0.42 | 0.12 |
| QRS duration (ms) | 135 ± 30 | 121 ± 33 | 106.9 ± 28 | 0.11 | 0.05 |
| NYHA functional class: | 0.18 | 0.1 | |||
| I | 1 (4.5) | 0 (0) | 2 (2.2) | ||
| II | 5 (22.7) | 22 (21.5) | 29 (31.5) | ||
| III | 12 (54.5) | 61 (59.8) | 44 (47.8) | ||
| IV | 4 (18) | 13 (12.7) | 17 (18.5) |
Values are mean ± SD or [median, interquartile range (IQR)] or n (%). DM, diabetes mellitus; BMI, body mass index; STS score, the society of thoracic surgeons scores; NYHA, New York Heart Association; SE, self-expandable; BE, balloon-expandable; THV, transcatheter heart valve.
Smaller borderline-BE-THV vs. larger borderline-BE-THV.
Larger borderline-BE-THV vs. non-borderline-SE.
Baseline echocardiography and MDCT characteristics of patients with BAAS for SE-THV implanted with SE or non-borderline BE-THV.
|
|
|
|
|
| |
|---|---|---|---|---|---|
| Distance of LM (mm) | 12.4 ± 3.2 | 12.6 ± 2.6 | 12.6 ± 2.7 | 0.26 | 0.39 |
| Distance of RCA (mm) | 14.8 ± 3 | 15.19 ± 2.9 | 14.9 ± 2.8 | 0.44 | 0.27 |
| AVA cm2 | 0.65 ± 0.13 | 0.74 ± 0.17 | 0.7 ± 0.19 | 0.3 | 0.3 |
| AV mean pressure (mmHg) | 45 ± 15 | 44 ± 14 | 48 ± 12 | 0.4 | 0.02 |
| LV Function | 0.189 | 0.52 | |||
| Normal (>55%) | 65 (70.6) | 120 (82) | 58 (84) | ||
| Mild (45–54%) | 7 (7.6) | 8 (5.4) | 6 (8.6) | ||
| Mild-moderate (40–44%) | 6 (6.5) | 4 (2.7) | 2 (2.8) | ||
| Moderate (35–39%) | 3 (3.2) | 7 (4.7) | 1 (1.4) | ||
| Moderate-severe (30–34%) | 5 (5.4) | 3 (2) | 2 (2.8) | ||
| Severe (<29%) | 6 (6.5) | 4 (2.7) | 0 (0) |
Values are mean ± SD or [median, interquartile range (IQR)] or n (%). LM, left main; RCA, right coronary artery; AV, aortic valve; AVA, aortic valve area; SE, self-expandable; BE, balloon-expandable; THV, transcatheter heart valve; LV, left ventricular.
Smaller borderline-SE-THV vs. larger borderline-SE-THV. #Larger borderline-SE-THV vs. non-borderline-BE.
Baseline echocardiography and MDCT characteristics of patients with BAAS for BE-THV implanted with BE or non-borderline SE-THV.
|
|
|
|
|
| |
|---|---|---|---|---|---|
| Distance of LM (mm) | 13.8 ± 2.7 | 13.69 ± 3 | 12.45 ± 2.49 | 0.36 | 0.0006 |
| Distance of RCA (mm) | 15.66 ± 3.2 | 16 ± 3.6 | 14.5 ± 3.12 | 0.25 | 0.0003 |
| AVA cm2 | 0.7 ± 0.16 | 0.76 ± 0.17 | 0.7 ± 0.19 | 0.55 | 0.144 |
| AV mean pressure (mmHg) | 45 ± 12.86 | 41 ± 16 | 44.2 ± 17.4 | 0.17 | 0.35 |
| LV function | 0.0192 | 0.35 | |||
| Normal (>55%) | 10 (47.6) | 68 (70.8) | 76 (80.8) | ||
| Mild (45–54%) | 3 (14.2) | 14 (14.5) | 12 (12.7) | ||
| Mild-moderate (40–44%) | 5 (23.8) | 4 (4.1) | 3 (3.2) | ||
| Moderate (35–39%) | 0 (0) | 3 (3.1) | 2 (2.1) | ||
| Moderate-severe (30–34%) | 1 (4.7) | 5 (5.2) | 1 (1) | ||
| Severe (<29%) | 2 (9.5) | 2 (2) | 0 (0) |
Values are mean ± SD or [median, interquartile range (IQR)] or n (%). LM, left main; RCA, right coronary artery; AV, aortic valve; AVA, aortic valve area; SE, self-expandable; BE, balloon-expandable; THV, transcatheter heart valve; LV, left ventricular.
Smaller borderline-BE-THV vs. larger borderline-BE-THV.
Larger borderline-BE-THV vs. non-borderline-SE.
Figure 3Incidence of paravalvular leak in patients with BAAS. BE, balloon-expandable; SE, self-expandable; THV, transcatheter heart valve; BAAS, borderline aortic annulus size; PVL, paravalvular leak.
Comparison of procedural and post-procedural outcomes between BAAS patients implanted with smaller vs. larger valves (SE or BE).
|
|
|
|
| |||
|---|---|---|---|---|---|---|
|
|
|
|
| |||
| Need for post-dilatation | 37 (40) | 57 (38) | 0.786 | 1 (4.7) | 8 (7.8) | 1 |
| device success (VARC-2) (%) | 91 (97) | 146 (97) | 1 | 22 (100) | 101(99) | 1 |
| Need for a second valve (%) | 2 (2) | 2 (1.3) | 0.638 | 0 (0) | 2 (1.9) | 1 |
| Valve malposition (%) | 2 (2) | 2 (1.3) | 0.638 | 0 (0) | 0 (0) | |
| Valve migration (%) | 2 (2) | 1 (0.6) | 0.565 | 0 (0) | 0 (0) | |
| Ischemic stroke/TIA (%) | 3 (3.2) | 2 (0.1) | 0.616 | 2 (9) | 0 (0) | 0.12 |
| Endocarditis (%) | 2 (2) | 0 (0) | 1 | 0 (0) | 1 (0.98) | 1 |
| Procedural mortality (%) | 1 (1) | 2 (0.1) | 0.599 | 0 (0) | 0 (0) | |
| Coronary obstruction (%) | 0 (0) | 0 (0) | 0 (0) | 0 (0) | ||
| New LBBB (%) | 21 (23) | 34 (23) | 0.882 | 4 (18.1) | 29 (28) | 0.471 |
| New pacemaker (%) | 16 (17) | 17 (11.3) | 0.4 | 2 (9) | 21 (20) | 0.521 |
| AV mean pressure (mmHg) | 10.2 ± 10.8 | 7.9 ± 5.4 | 0.083 | 12.5 ± 7.2 | 9.9 ± 3.7 | 0.019 |
| PVL per angiogram | 0.0088 | 0.403 | ||||
| None | 64 (68.8) | 128 (85.3) | 21 (95.4) | 88 (86) | ||
| Mild | 26 (27.9) | 20 (13.3) | 1 (4.5) | 14 (13.7) | ||
| Moderate | 3 (3.2) | 2 (1.3) | 0 (0) | 0 (0) | ||
| PVL per echo | 0.028 | 0.856 | ||||
| None (%) | 33 (35.5) | 82 (54.6) | 13 (59) | 68 (66.6) | ||
| Mild (%) | 51 (54.8) | 54 (36) | 8 (36) | 29 (28.4) | ||
| Mild-mod (%) | 6 (6.4) | 11 (7.3) | 1 (4.5) | 4 (3.9) | ||
| Moderate (%) | 2 (2.1) | 3 (2) | 0 (0) | 1 (0.98) | ||
| Moderate-severe (%) | 1 (1) | 0 (0) | 0 (0) | 0 (0) | ||
Values are mean ± SD or [median, interquartile range (IQR)] or n (%). VARC, valve academic research consortium; TIA, transient ischemic attack; LBBB, left bundle branch block; AV, aortic valve; PVL, paravalvular leak; echo, echocardiography; SE, self-expandable; BE, balloon-expandable; THV, transcatheter heart valve. Post-procedural outcomes (during index hospitalization) were endocarditis and new pacemaker implantation.
Figure 4Transcatheter heart valve hemodynamics in patients with BAAS. AV, aortic valve; BE, balloon-expandable; SE, self-expandable; THV, transcatheter heart valve, BAAS, borderline aortic annulus size.
Comparison of procedural and post-procedural outcomes between patients implanted with large borderline-SE vs. non-borderline-BE devices; or large borderline-BE vs. non-borderline-SE devices.
|
|
|
|
| |||
|---|---|---|---|---|---|---|
|
|
|
|
| |||
| Need for post dilatation | 57 (38) | 9 (12.8) | 0.0001 | 8 (7.8) | 34 (35.4) | 2.97e-06 |
| Device success (VARC-2) (%) | 146 (97) | 70 (100) | 0.554 | 101 (99) | 93 (96.8) | 0.11 |
| Need for a second valve (%) | 2 (1.3) | 0 (0) | 1 | 2 (1.9) | 2 (2) | 1 |
| Valve malposition (%) | 2 (1.3) | 0 (0) | 1 | 0 (0) | 1 (1) | 1 |
| Valve migration (%) | 1 (0.6) | 0 (0) | 1 | 0 (0) | 0 (0) | |
| Ischemic stroke/TIA (%) | 2 (0.1) | 0 (0) | 1 | 0 (0) | 2 (2) | 0.508 |
| Endocarditis (%) | 0 (0) | 1 (1.4) | 0.36 | 1 (0.98) | 1 (1) | 1 |
| Procedural mortality (%) | 2 (0.1) | 0 (0) | 0.528 | 0 (0) | 1 (1.6) | 0.927 |
| Coronary obstruction (%) | 0 (0) | 2 (3.3) | 0.166 | 0 (0) | 1 (1.6) | 0.927 |
| New LBBB (%) | 34 (23) | 17 (28.3) | 0.615 | 29 (28) | 27 (28.1) | 0.737 |
| New pacemaker (%) | 17 (11.3) | 9 (15) | 0.579 | 21 (20) | 17 (17.7) | 0.499 |
| AV mean pressure (mmHg) | 7.9 ± 5.4 (7, 4) | 12.1 ± 4.5 (12, 8) | 1.70e-10 | 9.9 ± 3.7 [9.6, 5] | 7.8 ± 3.5 (7, 5) | 3.90e-05 |
| PVL per echo | 0.246 | 0.191 | ||||
| None (%) | 82 (54.6) | 47 (67.1) | 68 (66.6) | 52 (54) | ||
| Mild (%) | 54 (36) | 20 (28.5) | 29 (28.4) | 36 (37.5) | ||
| Mild-mod (%) | 11 (7.3) | 3 (4.3) | 4 (3.9) | 6 (6.25) | ||
| Moderate (%) | 3 (2) | 0 (0) | 1 (0.98) | 2 (2) | ||
| Moderate-severe (%) | 0 (0) | 0 (0) | 0 (0) | 0 (0) | ||
| Overall PVL per echo | 68 (45.3) | 23 (32.8) | 0.106 | 34 (33) | 44 (45.8) | 0.0818 |
| PVL per echo | 0.699 | 0.0015 | ||||
| None (%) | 42 (45.1) | 16 (50) | 68 (72.3) | 14 (35.8) | ||
| Mild (%) | 40 (45.9) | 14 (43.7) | 23 (25.8) | 20 (51.2) | ||
| Mild-moderate (%) | 10 (11.4) | 2 (6.25) | 3 (3.37) | 4 (10.2) | ||
| Moderate (%) | 1 (1.1) | 0 (0) | 0 (0) | 1 (3) | ||
| Moderate-severe (%) | 0 (0) | 0 (0) | 0 (0) | 0 (0) | ||
| Overall PVL per echo | 51 | 16 | 0.413 | 26 | 25 | 0.0003 |
Values are mean ± SD or [median, interquartile range (IQR)] or n (%). VARC, valve academic research consortium; TIA, transient ischemic attack; LBBB, left bundle branch block; AV, aortic valve; PVL, paravalvular leak; SE, self-expandable; BE, balloon-expandable; THV, transcatheter heart valve; echo, echocardiography.
subgroup of patients who did undergo post-dilatation. Post-procedural outcomes (during index hospitalization) were endocarditis and new pacemaker implantation.